GE ds2020ucocn1g1a Keypad Display
GE ds2020ucocn1g1a Keypad Display
Part Number ds2020ucocn1g1a Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockDS2020UCOCN1G1A is an N1 OC2000 display under EX2000 series. This is a front mounting turbine management panel. The drive local area network is utilized to control and monitor other system components using the OC2000, a programmable operator interface (LAN). User-defined digital displays, usable pushbuttons, and indicator lights are all on the front panel of the device. System Hardware A LAN-based operator interface unit is called the OC2000. Two microprocessors are present in the device, and they are connected by an internal serial link.
The interface for users consists : 32 (2 sets of 16) programmable keys that are supported by status LEDs (LEDs) For local mode functions and diagnostics, a 16-key numeric/diagnostic keypad Two displays with 40 characters each and one with 12 characters System Software A software program is used to setup the OC2000 to specify its runtime operations. This program is known as the UC2000 Toolkit because it also configures the Unit Controller 2000 (UC2000) interface. The local mode utility offers online features including hardware resets and status information displays. DS2020UCOCN1G1A Features This board is often used in conjunction with the DACAG1 transformer assembly. The front display of the component is made up of numerous membrane switches.
These are divided into sections that are simple to use and comprehend. A readout for generation voltage, frequency, current, Mwatts, MVars, and power failure is included in the sections. P, C1, and C2 faults, as well as field voltages, amps, and temperature, are all available on a second readout. There are further parts dedicated to local control and diagnostic readout, as well as an "OC2000" area. Membrane switches, such as a numeric keyboard, an enter key, a help key, an escape/clear key, and keys for starting, stopping, and activating the system, are included in these parts. Airflow to the interior components is allowed through the unit's bottom rear panel. This aids in maintaining a comfortable temperature. Connectors like Ethernet, terminal connectors, and an RS-232 connector are also found on the back panel. The bottom rear panel of the unit allows airflow to the interior components. This aids in the maintenance of a comfortable temperature. A tophat flange on either side of the external cover has been drilled to allow easy attachment.
Compatibility
ƒ Compatible with any Series 90-30 CPU except IC693CPU321 and IC693CPU340. Configuration size is limited for CPU311/313/331, as described on the next page.
ƒ Requires release 8.0 CPU firmware. The latest Release 10 is recommended, if available for the particular CPU.
ƒ Requires CIMPLICITY Machine Edition Logic Developer PLC version 3.0 plus the appropriate service pack or special (or a version later than 3.0).
ƒ Not compatible with the VersaPro™, Control, or Logicmaster™ programming software.
ƒ The Series 90-30 Hand-Held Programmer (IC693PRG300) cannot be used to configure this module. New Features The Series 90-30 DeviceNet Master Module allows a Series 90-30 PLC to send and receive I/O data from a DeviceNet network.
Module features include:
ƒ Support for all standard data rates (125K, 250K, 500K)
ƒ Support for 255 bytes input data transfer and 255 bytes output data transfer per slave
ƒ Support for 3972 bytes of input data transfer and 3972 bytes of output data transfer per master
ƒ Support for two I/O connections per Slave - Typically one connection is used for Polled and the other is used for Strobe, Cyclic, or COS
ƒ Support for Poll, Strobe, Cyclic and COS I/O Connections, Fragmented I/O and Explicit Messaging
ƒ Support for Unconnected Message Manager (UCMM) with 1 proxy connection per slave device
ƒ Support for configuration of the global scan rate
ƒ Support for configuration of update rates for Poll and COS/Cyclic on a connection basis
ƒ Support for PLC-application initiated explicit messaging via a COMMREQ
ƒ Master can be configured to operate as a slave simultaneously with master operation
ƒ Configurable fault behavior on loss of communication
ƒ Reports loss or reestablishment of communication with slaves in PLC fault table (configurable)
ƒ Support for 64 network device status bits (note: the bit for the master itself is always zero)
ƒ Firmware update via service port on module