Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • FOXBORO H92 Process Automation System
    ❤ Add to collection
  • FOXBORO H92 Process Automation System

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    The H92EcoStruxure Foxboro DCS Standard Workstation can be used with EcoStruxure Foxboro DCS Control Core Services software and EcoStruxure Foxboro DCSControl Software, and can also provide a platform for Foxboro, third-party, and user-written applications.
    As amultipurpose workstation running the Windows 10 64-bit operating system, the H92 workstation supports execution of system applications, data communications for a broad range of applications, file serving capabilities, and display of graphics and text. It also interfaces with corporate networks at a local or worldwide level.

    • ¥16845.00
      ¥19064.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:0.280KG
    • Quantity:
    • (Inventory: 99999)
Description

The H92EcoStruxure Foxboro DCS Standard Workstation can be used with EcoStruxure Foxboro DCS Control Core Services software and EcoStruxure Foxboro DCSControl Software, and can also provide a platform for Foxboro, third-party, and user-written applications.
As amultipurpose workstation running the Windows 10 64-bit operating system, the H92 workstation supports execution of system applications, data communications for a broad range of applications, file serving capabilities, and display of graphics and text. It also interfaces with corporate networks at a local or worldwide level.


FOXBORO H92 Process Automation System

Overview

Vital software processes are often placed onto stand-alone workstations, with redundancy provided through replicating that configuration. This permits continued plant operation during maintenance as well as in the unusual event of workstation unavailability. Workstations can be remotely mounted in secured enclosures or spaces with the operator interface equipment installed through the use of Remote Graphics Units. The H92EcoStruxure Foxboro DCS Standard Workstation can be used with EcoStruxure Foxboro DCS Control Core Services software and EcoStruxure Foxboro DCSControl Software, and can also provide a platform for Foxboro, third-party, and user-written applications. As amultipurpose workstation running the Windows 10 64-bit operating system, the H92 workstation supports execution of system applications, data communications for a broad range of applications, file serving capabilities, and display of graphics and text. It also interfaces with corporate networks at a local or worldwide level. The workstation supports a mouse or optional trackball, an alphanumeric keyboard,up to four USB annunciator or annunciator/numeric keyboards, and one to four monitors. The H92 workstation also supports an optional USB touchscreen(purchased separately with the monitor) and an optional USB speaker set (purchased separately). The workstation features up to three internal serial ATA hard disk drives, which can be optionally configured as RAID1, and comes with 8 GB of ECC RAM memory(expandable to 16 GB). The processor supports an internal DVD+RW drive. Client/server communication is accomplished using the TCP/IP networking protocol with the integrated Ethernet network port or optional Ethernet network interface cards(NICs). As indicated by the CE logo, the Model H92 workstation conforms to the applicable European Union directives.


Workstation Security The Foxboro DCS workstation supports optional product features to allow customers to meet plant requirements for enhanced workstation security. Plant requirements for enhanced Foxboro DCS workstation security can be met through a combination of new product security enhancements as well as implementing best security policies,practices, and procedures. Foxboro DCS workstation enhanced product security requirements are supported in two broad categories, namely, workstation software including passwords, and workstation platform hardening. Workstation software supports: • Changeable login passwords • Individual user passwords • Passwordlock-out after a user-configurable number of unsuccessful login attempts and secured mechanisms to reset login • Passwordaging that requires password change on a periodic basis • Passwordsupport of alphanumeric and symbol characters as per Microsoft convention • Passwordfile protection


Installation Considerations These new security enhancements are supported only on Microsoft Windows 10 stations which support the control network and require a software update to the latest Foxboro DCS software release to obtain these security features. The security enhancements can be deployed on a subset of workstations to help increase security,but in order to maximize security protection, all workstations need to be updated to the latest software release to obtain the full benefits.


Optional Trellix®Software Packages See Trellix Security Products (PSS 41S-4Trellix) for the product specifications for the optional Trellix products.


Features

The Model H92 workstation, available with a Foxboro DCS software license, can: • HostFoxboro DCScontrol stations • Support data communications to directly connected process I/O devices • Serveasanapplication platform • Serveasahumantomachineinterface (HMI) station • Function on Ethernet control systems


Model H92 BaseConfiguration

• Intel Xeon ® processor 

• 8GBDDR-4ECCRegisteredRAM(expandableto16 GB) 

• 1TBSATAharddrive(expandable to up to 3 TB with a third hard drive) 

• PCIExpress ™ x16 video slot 

• Internal DVD+RW/CD drive 

• Quadmini-DP1.4 port PCIe graphics card with adapters to standard display port, up to 4 x1920x1080 (Full HD) pixel resolution 

• Integrated 10/100/1000BaseT Ethernet port 

• Universal Serial Bus (USB) interface ports for: 

◦ Mouse ◦ Keyboard ◦ Audiospeakers (optional) 

◦ Touchscreens (optional) ◦ USBannunciator keyboard (optional)


Model H92 Additional Options

• Addupto16GBofsystemRAM 

• Asecondorthird SATA hard drive 

• Aninternal SATA RAID1 system with an optional configuration of a hot spare with a third hard drive 

• Uptothree Ethernet network interface cards 

• GPSTimeSynchronization card 

• USBannunciator keyboards 

• Trackball • Analogmonitor graphics card (supports one to four analog monitors) 

• AHumanInterface up to 550 m (1804 ft) on 50/125my multi-mode cable, up to 5km(3.1 mi.) with 9/125my single mode cable extension unit (RGU) servicing these devices: 

◦ Uptofourvideo monitors 

◦ UptosixUSBdevices


Mounting Options

With quad PCIe video cards, the Model H92 workstation can be located up to 30 m (100 ft) from the monitor, using direct connect, analog video and other human interface cables available from Foxboro. This video connection will only operate when the Foxboro P/N RH924DF (100 ft VGA cable) is used or the RH103ER Mini Displayport to VGA adapter is used. 

Four mini DisplayPort to DisplayPort cables are included with the video card. The DisplayPort cables (RH103EN, RH103EP, and RH103EQ) are sold separately. 

Two optional Remote Graphics Unit (RGU) offerings are provided for each workstation to enable video, USB, and FireWire devices to be located at a distance from the workstation. For more information, see Remote Graphics Unit For H92 Workstations Overview, page 12. 

Devices that can be remote mounted via the RGU include monitors, the keyboard and mouse (or trackball), audio via USB speakers, USB touchscreens, and external USB drives

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide
  • Bonfiglioli Vectron CM-232/485 Modbus Communication Configuration Guide
  • Bonfiglioli BMS series servo reduction motor selection and integration guide
  • Bonfiglioli ACTION 210/410 Inverter Debugging and Fault Diagnosis Complete Guide
  • Honeywell Enhanced Micro TDC 3000X System Redundancy Architecture and Maintenance Guide
  • Selection and Configuration of Bonfiglioli Active Series Inverter
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli HDP/HDO Series Heavy duty Gearboxes
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli 300/300M Series Gearboxes
  • Bonfiglioli 300M planetary gearbox selection and thermal verification guide
  • Bonfiglioli 3/H series heavy-duty gearbox selection and verification guide
  • Bonfiglioli KRG/KCG/KSD Hydraulic Coupling Selection and Integration Guide