  • ABB NHAI06 Hart Adapter
    ❤ Add to collection
  • ABB NHAI06 Hart Adapter

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    NHAI06 Hart Adapter
    • ¥7474.00
      ¥12779.00
      ¥7474.00
      ¥7474.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.000KG
    • Quantity:
    • (Inventory: 2)
Description
NHAI06 Hart Adapter

ABB NHAI06 Hart Adapter

Functional features

Protocol conversion function: It realizes the conversion between HART protocol and other communication protocols, such as converting HART protocol to USB, Bluetooth and other common interface protocols, so that field devices supporting HART protocol can communicate with PCs, laptops and other devices.

Device Connection and Configuration: It can quickly and easily connect PC or laptop with field devices in HART network, and through the supporting Device Type Manager (DTM) software, it can configure, parameterize, diagnose and monitor HART field devices.

Multiple working modes: It supports working as a master or a slave, which can flexibly adapt to different HART network topologies and application requirements. When working as a master, it can initiate communication and data interaction with field devices; when working as a slave, it can respond to the commands of the master and provide corresponding data.

Intrinsically Safe: Some models have intrinsically safe features and comply with relevant explosion-proof standards, such as ATEX certification, which can be used safely in hazardous areas to ensure the safety of industrial sites.

Technical Parameters

Communication interface: usually equipped with USB interface or Bluetooth interface, USB interface is convenient to connect with the computer, Bluetooth interface provides the convenience of wireless connection, can be selected according to the actual needs. The communication baud rate generally supports the standard HART communication baud rate, such as 1200bps.

Power Requirement: The adapters powered by USB interface generally do not need external power supply, and get power directly from the USB interface, and the working voltage is usually around 5V. Bluetooth interface adapters may support battery power or USB power supply, and the battery is usually a common AAA battery or rechargeable lithium battery.

Operating Temperature Range: Generally, it can work normally in a wide temperature range, such as - 20℃ to + 60℃, and can adapt to the harsh environment of industrial sites.

Signal Transmission Characteristics: In terms of HART signal transmission, it can accurately modulate and demodulate the FSK signal specified in the HART protocol to ensure the convergence of digital communication and 4-20mA analog signals, and the signal transmission has a low BER to ensure the accuracy and reliability of the data.

Application Fields

Industrial automation field: Widely used in automation control systems in chemical, petroleum, natural gas, electric power and other industries, it is used to connect HART smart transmitters, flow meters, pressure gauges, liquid level gauges and other on-site instruments with the control system to realize accurate measurement and control of pressure, temperature, flow, liquid level and other parameters in the production process.

Smart Instrument Management and Maintenance: It is convenient for engineers to carry out on-site configuration, calibration, diagnosis and maintenance of HART smart instrument, and establish communication connection with the instrument through the adapter, so that they can remotely read the parameters and status information of the instrument, carry out troubleshooting and repair, improve the maintenance efficiency and reduce the downtime.

Industrial Internet of Things Integration: As a key component to realize the interconnection of industrial equipment, various HART devices can be connected to the industrial Internet of Things platform to realize remote monitoring, data analysis and optimization management of equipment, providing support for Industry 4.0 and smart manufacturing.

Technical Parameters

Communication interface: usually equipped with USB interface or Bluetooth interface, USB interface is convenient to connect with the computer, Bluetooth interface provides the convenience of wireless connection, can be selected according to the actual needs. The communication baud rate generally supports the standard HART communication baud rate, such as 1200bps.

Power Requirement: The adapters powered by USB interface generally do not need external power supply, and get power directly from the USB interface, and the working voltage is usually around 5V. Bluetooth interface adapters may support battery power or USB power supply, and the battery is usually a common AAA battery or rechargeable lithium battery.

Operating Temperature Range: Generally, it can work normally in a wide temperature range, such as - 20℃ to + 60℃, and can adapt to the harsh environment of industrial sites.

Signal Transmission Characteristics: In terms of HART signal transmission, it can accurately modulate and demodulate the FSK signal specified in the HART protocol to ensure the convergence of digital communication and 4-20mA analog signals, and the signal transmission has a low BER to ensure the accuracy and reliability of the data.

Application Fields

Industrial automation field: Widely used in automation control systems in chemical, petroleum, natural gas, electric power and other industries, it is used to connect HART smart transmitters, flow meters, pressure gauges, liquid level gauges and other on-site instruments with the control system to realize accurate measurement and control of pressure, temperature, flow, liquid level and other parameters in the production process.

Smart Instrument Management and Maintenance: It is convenient for engineers to carry out on-site configuration, calibration, diagnosis and maintenance of HART smart instrument, and establish communication connection with the instrument through the adapter, so that they can remotely read the parameters and status information of the instrument, carry out troubleshooting and repair, improve the maintenance efficiency and reduce the downtime.

Industrial Internet of Things Integration: As a key component to realize the interconnection of industrial equipment, various HART devices can be connected to the industrial Internet of Things platform to realize remote monitoring, data analysis and optimization management of equipment, providing support for Industry 4.0 and smart manufacturing.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Huichuan AM600 Motion Controller Malfunction and Replacement Guide
  • Allen Bradley Ultra3000 Servo Motor Replacement Guide
  • NEC NL8060BC26-17 LCD Module Maintenance and Replacement
  • ABB Pluto Safety PLC Maintenance and Troubleshooting
  • OMRON NE1A Safety Controller Troubleshooting and Replacement
  • Allen Bradley 2711P series PanelView Plus human-machine interface terminal
  • NI cFP-22xx on-site integration and troubleshooting
  • KEYENCE XG-8000 Line Scan Visual Debugging Guide
  • OMRON G9SX Security Unit Configuration and Troubleshooting
  • OMRON CPM1A Maintenance and Troubleshooting
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide