The FAZ-C2/1 circuit breaker belongs to the category of miniature circuit breakers (MCBs), and its core function is to quickly cut off overload and short circuit faults in the distribution circuit, avoiding safety accidents such as equipment damage, line burnout, and even fire caused by the expansion of faults. Its design follows international and national standards such as IEC 60898 and GB 10963.1, adopts a modular structure, is compact in size, and can be flexibly embedded into standard distribution boxes to meet the installation needs of various terminal distribution systems.
Core positioning and design philosophy of the product
The FAZ-C2/1 circuit breaker belongs to the category of miniature circuit breakers (MCBs), and its core function is to quickly cut off overload and short circuit faults in the distribution circuit, avoiding safety accidents such as equipment damage, line burnout, and even fire caused by the expansion of faults. Its design follows international and national standards such as IEC 60898 and GB 10963.1, adopts a modular structure, is compact in size, and can be flexibly embedded into standard distribution boxes to meet the installation needs of various terminal distribution systems.
The symbol "C2/1" in this model has a clear meaning: "C" represents the type of trip curve as C, suitable for circuits with mixed inductive and resistive loads, such as lighting, household appliances, and other common scenarios; 2 "represents a rated current of 2A, accurately matching the protection requirements of low-power circuits; '1' represents a pole number of 1P (single pole), which only protects the live wire and is suitable for single-phase 220V circuits.
Detailed explanation of key technical parameters
Technical parameters are the core basis for selecting and applying circuit breakers. The key parameters of FAZ-C2/1 are as follows, all of which comply with ABB's strict quality control standards:
1. Basic electrical parameters: rated voltage of 230V~(single-phase), rated frequency of 50/60Hz, suitable for the voltage and frequency requirements of China's civil and general commercial distribution systems; The rated short-circuit breaking capacity Icn is 6kA, which can instantly withstand and cut off up to 6kA of fault current in the event of a short-circuit fault, ensuring circuit safety.
2. Protection characteristics: As a C-type trip curve circuit breaker, its overload protection action current is 1.45~2.5 times the rated current (i.e. 2.9A~5A), and the short-circuit protection action current is 5~10 times the rated current (i.e. 10A~20A). This characteristic enables it to avoid false tripping caused by transient surge currents such as motor start-up, and to respond quickly in the event of a real fault.
3. Physical and environmental parameters: The external dimensions are 18mm wide, 89mm high, and 69mm deep, which conforms to modular design. The 1P pole number only occupies 1 standard modular number, saving space in the distribution box; The working environment temperature range is -25 ℃~+60 ℃, humidity ≤ 95% (no condensation), and can adapt to different climatic conditions in different regions; The protection level is IP20, which can effectively prevent solid foreign objects such as fingers from entering and is suitable for installation in distribution boxes.
Core performance advantages
Compared to ordinary miniature circuit breakers, FAZ-C2/1 relies on ABB's technological accumulation to demonstrate significant advantages in protection reliability, service life, and installation convenience:
-Accurate and fast protection performance: Adopting high-quality electromagnetic and thermal release dual mechanisms, the thermal release mechanism triggers overload protection through the deformation of bimetallic sheets, with precise and stable action; The electromagnetic trip mechanism quickly attracts and triggers a trip through electromagnetic force at the moment of a short circuit, with a breaking time of ≤ 0.02 seconds, which can minimize the duration of the fault and reduce losses to the greatest extent possible.
-High durability and stability: The contacts are made of silver alloy material, which has excellent conductivity and resistance to arc wear. The rated operating times are up to 10000 times (on-off), and the mechanical life is up to 20000 times, far exceeding the industry average level; The shell is made of flame-retardant grade UL94 V0 engineering plastic, which is resistant to high temperature and impact, and can effectively isolate danger under the action of fault arc.
-Convenient installation and operation: Adopting a snap on installation design, it can be directly inserted into a standard 35mm DIN rail, without the need for additional tools for installation, saving time and effort; The operating handle is clearly labeled with "ON", "OFF", and "TRIP" (trip) positions. After tripping, the handle automatically enters the middle position, making it easy to quickly identify the faulty circuit; At the same time, it supports positive wiring, and the wiring terminals adopt a crimping design, which ensures firm wiring and low contact resistance.
Applicable scenarios and selection suggestions
Based on its 2A rated current and C-type trip characteristics, FAZ-C2/1 circuit breaker is mainly suitable for the protection of low-power single-phase circuits. Typical application scenarios include:
1. Residential power distribution scenario: Used for low-power lighting circuits in living rooms, bedrooms, and other areas (such as multiple LED light series circuits), small household appliance dedicated circuits (such as routers, set-top boxes, small projectors, and other devices that operate at low power for a long time), to avoid overload or short circuit caused by aging lines, poor contact, etc.
2. Commercial and office scenarios: Suitable for small office equipment circuits such as desk lamps, printers, fax machines in office areas, as well as low-power load circuits such as embedded lighting and signage in shopping malls and convenience stores, ensuring electrical safety for office and business activities.
3. Small scale industrial and control scenarios: Used for small current circuits such as control circuits and sensor circuits in automation equipment, providing reliable protection for precision electronic components and avoiding faults that affect the operation of the entire equipment.
Attention should be paid when selecting: the rated current should be selected based on the actual load current of the circuit, ensuring that the calculated load current is ≤ 80% of the rated current of the circuit breaker (i.e. the maximum load current corresponding to FAZ-C2/1 is about 1.6A); At the same time, it is necessary to match the load type. The C-type curve is not suitable for pure resistive high current starting loads (such as electric water heaters) or pure inductive high impact loads (such as large motors). For such scenarios, B-type or D-type trip curve circuit breakers should be selected.
Installation and maintenance precautions
Proper installation and regular maintenance are key to ensuring the normal operation of circuit breakers, and the following points should be followed during use:
1. Installation specifications: Before installation, it is necessary to confirm that the circuit voltage matches the rated voltage of the circuit breaker, and disconnect the higher-level power supply to ensure safety; During installation, it should be firmly fixed to avoid looseness that may cause poor contact and heat generation; When wiring, it is necessary to ensure that the cross-sectional area of the wire meets the requirements (FAZ-C2/1 is compatible with copper core wires with a cross-sectional area of 1.5-4mm ²), and the stripping length is appropriate to avoid short circuits caused by exposed wires being too long.
2. Daily inspection: Regularly (recommended quarterly) check the appearance of the circuit breaker for any damage, discoloration, odor, or other abnormalities; Manually operate the joystick to switch between "ON" and "OFF" and confirm that the action is flexible and not stuck; If a trip occurs, it is necessary to first investigate the circuit fault (such as equipment short circuit, overload), eliminate the fault, and then reset the circuit breaker. Do not forcefully close it.
3. Fault handling: If the circuit breaker trips frequently, it is necessary to focus on checking whether the circuit load exceeds the rated value, whether there is insulation damage, short circuit or poor contact in the circuit, etc; If there is no output after the circuit breaker is closed, it may be due to damage to the tripping mechanism or internal component failure. The same model of circuit breaker should be replaced in a timely manner, and different specifications of products should not be replaced arbitrarily.
Product Certification and Quality Assurance
The FAZ-C2/1 circuit breaker has passed multiple authoritative certifications such as China CCC certification and EU CE certification, meeting international and domestic safety and performance standards. ABB provides a comprehensive quality assurance system for this product. Under normal use, the product warranty period is 1 year. If the product malfunctions due to quality issues, free repair or replacement services can be enjoyed with the purchase voucher.
In summary, ABB FAZ-C2/1 circuit breaker has become an ideal choice for low-power single-phase circuit protection due to its precise protection performance, high reliability, and convenient installation and operation. In the process of selection and use, it is necessary to combine the actual load characteristics and installation requirements, strictly follow the specifications, in order to fully play its protective role and ensure the safe and stable operation of the distribution system.