Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB FAZ-C6/1  Miniature circuit breaker
    ❤ Add to collection
  • ABB FAZ-C6/1 Miniature circuit breaker

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    ABB FAZ-C6/1 belongs to the FAZ series of miniature circuit breakers, which are high-performance products launched by ABB for low-voltage distribution systems. The design core is "miniaturization, high reliability, and easy operation". Among them, the identification of "C6/1" contains clear product information: "C" represents the type of trip curve, suitable for conventional lighting and power hybrid loads; 6 "represents a rated current of 6A, accurately matching the requirements of medium and low load circuits; '1' represents a 1-pole structure, suitable for protection of single-phase circuits.

    • ¥15738.00
      ¥17838.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:0.830KG
    • Quantity:
    • (Inventory: 99999)
Description

ABB FAZ-C6/1 belongs to the FAZ series of miniature circuit breakers, which are high-performance products launched by ABB for low-voltage distribution systems. The design core is "miniaturization, high reliability, and easy operation". Among them, the identification of "C6/1" contains clear product information: "C" represents the type of trip curve, suitable for conventional lighting and power hybrid loads; 6 "represents a rated current of 6A, accurately matching the requirements of medium and low load circuits; '1' represents a 1-pole structure, suitable for protection of single-phase circuits.




ABB FAZ-C6/1 miniature circuit breaker

Core positioning and design philosophy of the product

ABB FAZ-C6/1 belongs to the FAZ series of miniature circuit breakers, which are high-performance products launched by ABB for low-voltage distribution systems. The design core is "miniaturization, high reliability, and easy operation". Among them, the identification of "C6/1" contains clear product information: "C" represents the type of trip curve, suitable for conventional lighting and power hybrid loads; 6 "represents a rated current of 6A, accurately matching the requirements of medium and low load circuits; '1' represents a 1-pole structure, suitable for protection of single-phase circuits.

The product adopts high-strength flame-retardant shell material, which meets international electrical standards and can effectively resist high temperatures and arcs generated during circuit faults, avoiding secondary safety hazards caused by shell combustion. At the same time, the compact modular design allows it to be flexibly embedded into standard distribution boxes, saving installation space and adapting to various distribution layout requirements.


Analysis of Key Technical Parameters

Accurate technical parameters are the foundation for reliable protection of miniature circuit breakers. The core parameters of ABB FAZ-C6/1 are as follows, providing clear basis for selection and application:

-Model identification: FAZ-C6/1

-Number of poles: 1 pole

-Tripping curve: C-type (tripping current is 5-10 times the rated current), suitable for mixed resistive and inductive loads, such as lighting systems, small motors, household appliances, etc. It can avoid false tripping caused by normal starting current and quickly act in case of faults.

-Rated current (In): 6A, the maximum safe current allowed to pass during continuous operation. When this value is exceeded and the set threshold is reached, the circuit breaker will trigger overload protection.

-Rated voltage (Un): AC 230/400V, suitable for the standard voltage level of China's low-voltage distribution system, can be used for single-phase 220V circuits or single-phase branch circuits of three-phase 400V systems.

-Rated short-circuit breaking capacity (Icn): up to 6kA (some specifications can reach 10kA, please refer to the product manual for details), it can quickly cut off the fault current in the event of a short circuit fault in the circuit, avoiding serious consequences such as arc burns and equipment damage.

-Protection function: Overload protection, short circuit protection, dual protection mechanism comprehensively covers common types of faults in the circuit.

-Installation method: Standard DIN rail installation, in compliance with international installation standards, easy and stable installation, convenient for later maintenance and replacement.

-Mechanical lifespan: ≥ 10000 cycles, electrical lifespan ≥ 1000 cycles, with a long service life and reduced replacement costs in the later stage.


Core performance advantages

As a mature product under ABB, FAZ-C6/1 demonstrates multiple performance advantages through its exquisite manufacturing process and technological innovation

1. Precise protection and rapid response

Adopting a high-precision trip mechanism, the response time for overload and short circuit faults has been strictly calibrated. When the circuit is overloaded, the circuit breaker will delay the action according to the magnitude of the overload current to avoid false triggering caused by instantaneous surge current; When a serious fault such as a short circuit occurs, it can quickly disconnect the circuit within milliseconds, minimizing the damage to the circuit and equipment caused by the fault.

2. High reliability and stable operation

ABB has a comprehensive quality control system, and FAZ-C6/1 undergoes multiple rigorous inspections from raw material procurement to production assembly. The internal conductive components are made of high conductivity copper material to reduce contact resistance and minimize heat loss; The release mechanism is made of wear-resistant and aging resistant engineering plastics and metal components, ensuring stable performance even after long-term use, suitable for frequent start stop circuit scenarios.

3. Humanized design, easy to operate

The product is equipped with clear on/off indicators, and the "ON" and "OFF" states are clear at a glance, making it easy for maintenance personnel to quickly determine the circuit status. At the same time, the operating handle has a comfortable feel and smooth opening and closing actions, making it easy to operate even in small distribution box spaces. In addition, the modular structure of the circuit breaker allows it to be flexibly combined with ABB FAZ series leakage protection accessories, overvoltage protection accessories, etc., expanding its protection functions and meeting personalized distribution needs.

4. Environmental protection and safety, in compliance with standards

The shell is made of halogen-free flame retardant material, which not only has excellent flame retardant performance, but also reduces environmental pollution after disposal and complies with environmental standards such as EU RoHS. The product has passed the certification of IEC International Electrotechnical Commission standards and Chinese GB standards, and its safety performance and quality have reached the international advanced level. It can be safely applied to various formal distribution projects.


Applicable scenarios

Based on its 6A rated current and C-type trip curve characteristics, ABB FAZ-C6/1 miniature circuit breaker has a wide range of application scenarios, mainly concentrated in single-phase distribution circuits with medium and low loads, including:

-Civil building scenarios: lighting circuits in residential homes and apartments (such as lighting circuits in living rooms and bedrooms), small household appliance circuits (such as power supply circuits for low-power devices such as routers, set-top boxes, and small printers), can effectively protect household electricity safety and avoid fire hazards caused by aging appliances and short circuits in circuits.

-Commercial office scenarios: Branch circuits for office equipment in buildings and offices (such as centralized power supply circuits for computers, fax machines, projectors, etc.), branch circuits for lighting systems, to ensure stable operation of office equipment and reduce work interruptions caused by circuit failures.

-Small commercial scenarios: lighting circuits and cashier equipment circuits in convenience stores and small supermarkets, as well as low-power equipment power supply circuits in small shops such as hair salons and nail salons, to meet the frequent electricity needs of commercial places and improve electricity safety.

-Industrial auxiliary scenario: Low load circuits such as control circuits and instrument circuits in industrial plants provide stable circuit protection for precise control of industrial equipment, avoiding control circuit failures that affect the operation of main equipment.


Installation and maintenance precautions

Proper installation and maintenance are key to ensuring optimal performance of ABB FAZ-C6/1 miniature circuit breakers, and the following points should be noted:

1. Installation specifications

Before installation, it is necessary to confirm that the model, rated parameters, and circuit requirements of the circuit breaker match; During installation, it is necessary to strictly follow the DIN rail installation requirements to ensure a secure installation and avoid loose connections that may cause poor contact; When wiring, it is necessary to ensure that the wire is in close contact with the terminal block. Suitable crimping terminals should be selected according to the wire specifications to avoid heating faults caused by thin wires or loose crimping; The installation environment should be kept dry and ventilated to avoid erosion by dust, oil, and corrosive gases.

2. Maintenance points

Regularly check the on/off status indication of the circuit breaker during daily operation and maintenance to confirm that it is in the normal working position; Regularly clean the surface of the circuit breaker with a dry cloth to avoid dust accumulation; When a circuit failure causes the circuit breaker to trip, it is necessary to first investigate the cause of the fault (such as overload equipment, short-circuit lines, etc.), eliminate the fault, and then reset the circuit breaker. Do not forcefully close it; If the circuit breaker frequently trips or experiences appearance damage, abnormal heating, etc., it should be replaced in a timely manner to avoid safety hazards caused by continued use.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide
  • ASEM HT2150 Industrial Tablet Selection and Troubleshooting
  • Troubleshooting and practical application of Advantest U3771/3772 microwave spectrum analyzer
  • Advantest R6144 Programmable DC Voltage/Current Source (Calibration Source) Calibration and Maintenance
  • Aerotech UNIDEX 100/U100i single axis motion controller
  • Aerotech Ndrive MP Ultra Compact PWM Digital Servo Driver
  • Aerotech Ndrive HPe 10/20/30 High Performance PWM Digital Servo Drive
  • Aerotech Ndrive HLe maintenance replacement
  • Aerotech Ndrive CP maintenance replacement
  • Aerotech Ndrive Linear Drive Selection
  • Aerotech NDrive HL linear drive maintenance replacement
  • Aerotech NDrive HP 10/20/30 Maintenance and Replacement
  • Aerotech NDrive CP10 Servo Drive Guide
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications