ABB FAZ-C6/1 belongs to the FAZ series of miniature circuit breakers, which are high-performance products launched by ABB for low-voltage distribution systems. The design core is "miniaturization, high reliability, and easy operation". Among them, the identification of "C6/1" contains clear product information: "C" represents the type of trip curve, suitable for conventional lighting and power hybrid loads; 6 "represents a rated current of 6A, accurately matching the requirements of medium and low load circuits; '1' represents a 1-pole structure, suitable for protection of single-phase circuits.
Core positioning and design philosophy of the product
ABB FAZ-C6/1 belongs to the FAZ series of miniature circuit breakers, which are high-performance products launched by ABB for low-voltage distribution systems. The design core is "miniaturization, high reliability, and easy operation". Among them, the identification of "C6/1" contains clear product information: "C" represents the type of trip curve, suitable for conventional lighting and power hybrid loads; 6 "represents a rated current of 6A, accurately matching the requirements of medium and low load circuits; '1' represents a 1-pole structure, suitable for protection of single-phase circuits.
The product adopts high-strength flame-retardant shell material, which meets international electrical standards and can effectively resist high temperatures and arcs generated during circuit faults, avoiding secondary safety hazards caused by shell combustion. At the same time, the compact modular design allows it to be flexibly embedded into standard distribution boxes, saving installation space and adapting to various distribution layout requirements.
Analysis of Key Technical Parameters
Accurate technical parameters are the foundation for reliable protection of miniature circuit breakers. The core parameters of ABB FAZ-C6/1 are as follows, providing clear basis for selection and application:
-Model identification: FAZ-C6/1
-Number of poles: 1 pole
-Tripping curve: C-type (tripping current is 5-10 times the rated current), suitable for mixed resistive and inductive loads, such as lighting systems, small motors, household appliances, etc. It can avoid false tripping caused by normal starting current and quickly act in case of faults.
-Rated current (In): 6A, the maximum safe current allowed to pass during continuous operation. When this value is exceeded and the set threshold is reached, the circuit breaker will trigger overload protection.
-Rated voltage (Un): AC 230/400V, suitable for the standard voltage level of China's low-voltage distribution system, can be used for single-phase 220V circuits or single-phase branch circuits of three-phase 400V systems.
-Rated short-circuit breaking capacity (Icn): up to 6kA (some specifications can reach 10kA, please refer to the product manual for details), it can quickly cut off the fault current in the event of a short circuit fault in the circuit, avoiding serious consequences such as arc burns and equipment damage.
-Protection function: Overload protection, short circuit protection, dual protection mechanism comprehensively covers common types of faults in the circuit.
-Installation method: Standard DIN rail installation, in compliance with international installation standards, easy and stable installation, convenient for later maintenance and replacement.
-Mechanical lifespan: ≥ 10000 cycles, electrical lifespan ≥ 1000 cycles, with a long service life and reduced replacement costs in the later stage.
Core performance advantages
As a mature product under ABB, FAZ-C6/1 demonstrates multiple performance advantages through its exquisite manufacturing process and technological innovation
1. Precise protection and rapid response
Adopting a high-precision trip mechanism, the response time for overload and short circuit faults has been strictly calibrated. When the circuit is overloaded, the circuit breaker will delay the action according to the magnitude of the overload current to avoid false triggering caused by instantaneous surge current; When a serious fault such as a short circuit occurs, it can quickly disconnect the circuit within milliseconds, minimizing the damage to the circuit and equipment caused by the fault.
2. High reliability and stable operation
ABB has a comprehensive quality control system, and FAZ-C6/1 undergoes multiple rigorous inspections from raw material procurement to production assembly. The internal conductive components are made of high conductivity copper material to reduce contact resistance and minimize heat loss; The release mechanism is made of wear-resistant and aging resistant engineering plastics and metal components, ensuring stable performance even after long-term use, suitable for frequent start stop circuit scenarios.
3. Humanized design, easy to operate
The product is equipped with clear on/off indicators, and the "ON" and "OFF" states are clear at a glance, making it easy for maintenance personnel to quickly determine the circuit status. At the same time, the operating handle has a comfortable feel and smooth opening and closing actions, making it easy to operate even in small distribution box spaces. In addition, the modular structure of the circuit breaker allows it to be flexibly combined with ABB FAZ series leakage protection accessories, overvoltage protection accessories, etc., expanding its protection functions and meeting personalized distribution needs.
4. Environmental protection and safety, in compliance with standards
The shell is made of halogen-free flame retardant material, which not only has excellent flame retardant performance, but also reduces environmental pollution after disposal and complies with environmental standards such as EU RoHS. The product has passed the certification of IEC International Electrotechnical Commission standards and Chinese GB standards, and its safety performance and quality have reached the international advanced level. It can be safely applied to various formal distribution projects.
Applicable scenarios
Based on its 6A rated current and C-type trip curve characteristics, ABB FAZ-C6/1 miniature circuit breaker has a wide range of application scenarios, mainly concentrated in single-phase distribution circuits with medium and low loads, including:
-Civil building scenarios: lighting circuits in residential homes and apartments (such as lighting circuits in living rooms and bedrooms), small household appliance circuits (such as power supply circuits for low-power devices such as routers, set-top boxes, and small printers), can effectively protect household electricity safety and avoid fire hazards caused by aging appliances and short circuits in circuits.
-Commercial office scenarios: Branch circuits for office equipment in buildings and offices (such as centralized power supply circuits for computers, fax machines, projectors, etc.), branch circuits for lighting systems, to ensure stable operation of office equipment and reduce work interruptions caused by circuit failures.
-Small commercial scenarios: lighting circuits and cashier equipment circuits in convenience stores and small supermarkets, as well as low-power equipment power supply circuits in small shops such as hair salons and nail salons, to meet the frequent electricity needs of commercial places and improve electricity safety.
-Industrial auxiliary scenario: Low load circuits such as control circuits and instrument circuits in industrial plants provide stable circuit protection for precise control of industrial equipment, avoiding control circuit failures that affect the operation of main equipment.
Installation and maintenance precautions
Proper installation and maintenance are key to ensuring optimal performance of ABB FAZ-C6/1 miniature circuit breakers, and the following points should be noted:
1. Installation specifications
Before installation, it is necessary to confirm that the model, rated parameters, and circuit requirements of the circuit breaker match; During installation, it is necessary to strictly follow the DIN rail installation requirements to ensure a secure installation and avoid loose connections that may cause poor contact; When wiring, it is necessary to ensure that the wire is in close contact with the terminal block. Suitable crimping terminals should be selected according to the wire specifications to avoid heating faults caused by thin wires or loose crimping; The installation environment should be kept dry and ventilated to avoid erosion by dust, oil, and corrosive gases.
2. Maintenance points
Regularly check the on/off status indication of the circuit breaker during daily operation and maintenance to confirm that it is in the normal working position; Regularly clean the surface of the circuit breaker with a dry cloth to avoid dust accumulation; When a circuit failure causes the circuit breaker to trip, it is necessary to first investigate the cause of the fault (such as overload equipment, short-circuit lines, etc.), eliminate the fault, and then reset the circuit breaker. Do not forcefully close it; If the circuit breaker frequently trips or experiences appearance damage, abnormal heating, etc., it should be replaced in a timely manner to avoid safety hazards caused by continued use.





Email:wang@kongjiangauto.com