Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE 845REF-B2 Transformer Protection System
    ❤ Add to collection
  • GE 845REF-B2 Transformer Protection System

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE 845REF-B2 Transformer Protection System

    • ¥23650.00
      ¥34670.00
      ¥23650.00
      ¥23650.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.400KG
    • Quantity:
    • (Inventory: 33)
Description

GE 845REF-B2 Transformer Protection System


GE 845REF-B2 Transformer Protection System

DESCRIPTION

The Multilin™ 845 Transformer Protection System is a member of the Multilin 8 Series protective relay platform and has been designed for the protection, control and management of 2- and 3-winding power and distribution transformers in both utility and industrial applications.

The Multilin 845 provides advanced functionality for a wide range of transformer applications delivering high-speed protection, customizable programmable logic, advanced transformer monitoring and diagnostics, and support for the latest communications protocols for easy integration into new or existing power systems.

The Multilin 845 delivers comprehensive transformer health monitoring, diagnostics, and reporting with integrated connectivity to composite and multiple gas transformer DGA solutions such as, GE’s Kelman Transformer Monitoring devices, delivering actionable analytics for asset optimization and transformer life extension.

KEY BENEFITS 

Comprehensive transformer protection including fast operating differential protection, unique CT saturation and directional detection

Advanced transformer monitoring, diagnostics and disturbance recording extending asset life

Integrated protection & DGA for continuous transformer monitoring

Integrated arc flash detection using light sensors to reduce incident energy and equipment damage

High-end cyber security tools such as AAA, Radius, RBAC, and Syslog enabling NERC CIP requirements

Draw-out design simplifies testing, commissioning and maintenance

Optional Wi-Fi minimizes system configuration and facilitates safe relay programming and diagnostic retrieval

Monitored environmental conditions helps reduce system downtime

High flexibility for customized protection and control logic

Innovative Technology & Design

Patented environmental monitoring and diagnostics helps visibility on change in environmental parameters

Advanced, flexible and embedded communications: IEC® 61850 Ed2, IEC 62439/PRP, Modbus® RTU & TCP/IP, DNP3.0, IEC 60870-5-104, IEC 60870-5-103

Single setup and configuration across the platform

Field swappable power supply

Draw-out design simplifies testing, commissioning and maintenance, thereby increasing process uptime

Optional Wi-Fi connectivity minimizes system configuration and provides safe relay programming and diagnostic retrieval

Elimination of electrolytic capacitors

Exceptional Quality & Reliability

IPC A-610-E Class 3 Manufacturing standards – highest industry standards for electronic manufacturing

Highest reliability standards for electronics testing

Environmental Stress Screening and full functional testing

Rated for IP54 applications

Standard Harsh Conformal Coating

CAUTION

• Failure to observe and follow the instructions provided in the equipment manual(s)  could cause irreversible damage to the equipment and could lead to property  damage, personal injury and/or death.  

• Before attempting to use the equipment, it is important that all danger and  caution indicators are reviewed.  

• If the equipment is used in a manner not specified by the manufacturer or  functions abnormally, proceed with caution. Otherwise, the protection provided by  the equipment may be impaired and can result in Impaired operation and injury. 

• Caution: Hazardous voltages can cause shock, burns or death. 

• Installation/service personnel must be familiar with general device test practices,  electrical awareness and safety precautions must be followed.  

• Before performing visual inspections, tests, or periodic maintenance on this device  or associated circuits, isolate or disconnect all hazardous live circuits and sources  of electric power.  

• Failure to shut equipment off prior to removing the power connections could  expose you to dangerous voltages causing injury or death.  

• All recommended equipment that should be grounded and must have a reliable  and un-compromised grounding path for safety purposes, protection against  electromagnetic interference and proper device operation. 

• Equipment grounds should be bonded together and connected to the facility’s  main ground system for primary power. 

• Keep all ground leads as short as possible.  

• At all times, equipment ground terminal must be grounded during device  operation and service.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer
  • UniOP ePAD32B/ePAD33B/ePAD33BT Industrial HMI
  • UniOP ePAD05/06 Human Computer Interface
  • UniOP ePAD03/04 Human Computer Interface
  • UniOP BKDR-46-0045 Human Machine Interface
  • UniOP BKDR-16 human-machine interface
  • Beckwith M-3425A Relay Guide
  • Basler DECS-200-2L excitation system
  • Basler DECS-250 Excitation System Debugging Guide
  • HA-800A Servo Drive Debugging Guide
  • JUMO dTRANS p35 Manual
  • KEBA XE020 RFID Module Manual
  • Honeywell SmartLine Transmitter Complete Guide
  • Eaton CROUSE-HINDS Series MA30 Lightning Protection Filter Installation Guide
  • BECKHOFF EL31xx Series 16 Bit EtherCAT Analog Input Terminal Manual
  • BECKHOFF AX5000 Servo Drive Maintenance Guide
  • BECKHOFF EL30xx Analog Input Diagnostic Guide
  • BECKHOFF EL70x7 Stepper Terminal Maintenance Guide
  • BECKHOFF CX52x0 Industrial Control Computer Maintenance Guide
  • BECKHOFF CX9000/CX9010 Hardware Maintenance Guide
  • BECKHOFF AM8xxx Motor Guide
  • BECKHOFF EL9xxx System Terminal Guide
  • Beckhoff EK110x/EK15xx Coupling Guide
  • BECKHOFF CX51x0 Embedded PC Deployment Guide
  • BECKHOFF CX2100-0014 Power Module Guide
  • BECKHOFF CX1000 Industrial Control PC Complete Manual
  • BECKHOFF CP69xx Panel Installation and Troubleshooting
  • Beckhoff C6030-0080 Industrial Control PC Guide
  • IFM O3D300 3D Sensor Debugging and Troubleshooting Guide
  • Allen Bradley Guardmaster 440R Safety Relay Troubleshooting and Configuration Guide
  • OMRON CS1 PLC System Maintenance and Troubleshooting Guide
  • GE Multilin EPM 9900P Power Quality Instrument Debugging and Fault Diagnosis Guide
  • Automotive LC-4 DC Brushless Motor Controller Debugging and Fault Diagnosis Guide
  • Doric NC500 Console Debugging and Troubleshooting Guide
  • Honeywell X-DCS2000/EN System Manager Debugging and Fault Diagnosis Guide
  • Kollmorgen SERVOSTAR 600 Servo Drive Field Troubleshooting and Maintenance Guide
  • ABB XFC Series Flow Computer Maintenance Guide
  • ABB ACS6000 Inverter IGCT Phase Module Replacement and Maintenance Guide
  • OMRON NX502 CPU Unit Hardware Installation and Maintenance Guide
  • OMRON NX102 Hardware Installation Guide
  • OMRON C200HX/HG/HE PLC Troubleshooting
  • Yamatake SDC35/36 Controller Application Guide
  • MITSUBISHI ELECTRIC GT25 Human Computer Interface Application Guide
  • Eurotherm Mini8 Controller Integration Guide
  • KEYENCE GC-1000 Safety Controller Manual
  • SICK RLY3-EMSS300 Safety Relay Manual
  • Troubleshooting of Siemens SIRIUS 3SK2 Safety Relay
  • Nordson DAGE4000 Bond Tensile Tester
  • HMS Anybus Communicator Gateway Replacement and Troubleshooting Guide
  • Allen Bradley 800T/H 30mm Button Troubleshooting and Replacement Guide
  • Schneider Modicon M340 Strict Environment Deployment and Troubleshooting Guide
  • Kepco BOP 1000M Troubleshooting Application
  • Siemens SIPROTEC 5 Replacement and Upgrade Guide
  • Banner XS/SC26 Security Controller Debugging and Troubleshooting
  • Allen Bradley MicroLogix 1500 Installation and Debugging
  • EOCR-PMZ (panel embedded) and EOCR-PFZ (embedded) motor comprehensive protector
  • Microchip PIC16F182X Low Power Design
  • FANUC α iS servo HRV calibration practice
  • Mitsubishi Electric GT23 Series HMI Maintenance Guide
  • Mitsubishi GT27 HMI Application Guide
  • Siemens SIMATIC ET 200M Selection
  • Lenze 8200 Vector Selection
  • Troubleshooting of Siemens MASTER DRIVES VC
  • FANUC I/O Unit A Maintenance Manual
  • Allen Bradley PLC-5 Classic Controller Complete Guide
  • Maintenance of M&C SP2006-H/DIL Sampling Probe
  • Pro face connection to Mitsubishi DIASYS Netmation
  • OMRON SYSMAC C-series/CVM1/CV series analog I/O units
  • LTI ServoOne Replacement and Troubleshooting
  • OMRON C-series AD/DA module configuration
  • Siemens 840C 611D Module Replacement Guide
  • Diagnosis and maintenance of ABB ACS550 frequency converter fault codes
  • OMRON NX1P2 Hardware Debugging Guide
  • Fuji FRENIC Mini inverter troubleshooting
  • Braided Forissier Braided Copper Strip Selection Guide
  • Mecc Alte MC200 Controller Engineering Debugging and Troubleshooting
  • Schneider Square D 9036/9037/9038 Electromechanical Liquid Level Controller
  • Pilz PSS 4000 distributed safety control
  • Schneider TeSys GV5/GV6 Motor Circuit Breaker Operation and Protection Guide
  • Eaton Freedom NEMA Contactor Starter Complete Guide
  • OMRON D4SL-N/D4SL-NSK10-LK Safety Door Switch Comprehensive Guide
  • NI CompactRIO Embedded System
  • Emerson Ovation I/O Module Troubleshooting and Replacement Practical Guide
  • MITSUBISHI A-series PLC Troubleshooting Replacement
  • Automation Direct DL06 D0-06DD1 Replacement Guide
  • IFM CR2530 Intelligent Controller Guide
  • OMRON FH/FHV series visual sensor controller
  • Pilz PDP67 F4 code troubleshooting
  • Panasonic FP-X PLC Replacement and Troubleshooting
  • OMRON CK3W-AX Multi axis Control Selection
  • Debugging and maintenance of EPSON RC90/RC90-B controller
  • Nthytronic Group iRTUe I/O Expansion Module
  • Schneider ATV320 Inverter Installation and Debugging Guide
  • Eaton SPB Drawdown Switch Maintenance Guide
  • GFS EVO-SP dual fuel retrofit complete solution
  • OMRON CJ2 CPU Troubleshooting and Maintenance
  • Complete Guide to Lenze ECS Servo System
  • GE EX2100e Excitation System Complete Guide
  • OMRON G3PW Power Controller: Parameter Setting and Troubleshooting Guide
  • Key Points for Selection and Deployment of MITSUBISHI FX3GE PLC
  • Beckhoff EP23xx EtherCAT Box Selection Troubleshooting
  • MITSUBISHI MDS-B servo troubleshooting
  • TOYO valve pressure and temperature selection
  • SIEMENS SIMODRIVE 611 HR/HRS Replacement and Advanced Positioning Techniques
  • SIEMENS SINUMERIK 840C 611-D Startup and Troubleshooting Guide
  • FANUC Series 0i-F Maintenance and Troubleshooting
  • Troubleshooting Schneider Modicon TM3 Bus Expansion
  • Troubleshooting of R&S EPL1000
  • Baum ü llerb b maXX 5000 Safety Configuration and Troubleshooting Guide
  • Huichuan AM600 Motion Controller Malfunction and Replacement Guide
  • Allen Bradley Ultra3000 Servo Motor Replacement Guide
  • NEC NL8060BC26-17 LCD Module Maintenance and Replacement
  • ABB Pluto Safety PLC Maintenance and Troubleshooting
  • OMRON NE1A Safety Controller Troubleshooting and Replacement
  • Allen Bradley 2711P series PanelView Plus human-machine interface terminal
  • NI cFP-22xx on-site integration and troubleshooting
  • KEYENCE XG-8000 Line Scan Visual Debugging Guide
  • OMRON G9SX Security Unit Configuration and Troubleshooting
  • OMRON CPM1A Maintenance and Troubleshooting
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch