  • Foxboro PBCO-D8-010 FBM I/O cards
    ❤ Add to collection
  • Foxboro PBCO-D8-010 FBM I/O cards

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    The Termination Board (TB) model PBCO-D8-010 is designed to connect the D1000 Series Intrinsically Safe isolation and protection modules, directly to the Foxboro FBM I/O cards type FBM201, FBM237, FBM204 and FBM205 without the standard Field Termination Assembly normally needed to interface the backplane. 

    • ¥16945.00
      ¥16956.00
      ¥16945.00
      ¥16945.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:0.680KG
    • Quantity:
    • (Inventory: 99999)
Description

The Termination Board (TB) model PBCO-D8-010 is designed to connect the D1000 Series Intrinsically Safe isolation and protection modules, directly to the Foxboro FBM I/O cards type FBM201, FBM237, FBM204 and FBM205 without the standard Field Termination Assembly normally needed to interface the backplane. 


Foxboro PBCO-D8-010 FBM I/O cards

General description: 

The Termination Board (TB) model PBCO-D8-010 is designed to connect the D1000 Series Intrinsically Safe isolation and protection modules, directly to the Foxboro FBM I/O cards type FBM201, FBM237, FBM204 and FBM205 without the standard Field Termination Assembly normally needed to interface the backplane. 

The TB consists of D1000 Series modules mounted on backplane which carry Safe Area signals and supply. The range of modules includes different types to handle the majority of applications. 

The TB PBCO-D8-010 connector is pin to pin compatible with the standard system cable, thus avoiding the need of special cable or external wiring. 

The TB connectors link with the Provox I/O cards by standard Provox cable (see connection tables for details). 

The FBM201 is a 8 channels, 4-20 mA analog input board. The FBM237 is a 8 channels, 4-20 mA analog output board.

The FBM204 is a 4 channels 4-20 mA analog input plus 4 channels 4-20 mA analog output board.

The FBM205 is a 4 channels 4-20 mA analog input plus 4 channels 4-20 mA analog output board.

The TB is provided with two connectors to interface two FBM I/O cards.

The Intrinsic Safety protection and signal isolation is made through the D1000 Series Associated Apparatus. The modules type accepted are:

Analog Input D1010D, D1014D, D1052D, D1072D to interface FBM201;

Analog Output D1020D to interface FBM237;

Analog Input D1010D, D1014D, D1052D, D1072D plus Analog Output D1020D to interface FBM204 or FBM205. The TB can accept 16 input channels AI or AO, and can only be used for 2 channels modules.

The connections to/from the Hazardous Areas are made at the module terminal blocks, thus avoiding the TB Intrinsic Safety certifications, resulting in a quick design and cost effective solution.

The 24 Vdc power supply for the TB is connected to a two dual plug-in terminal blocks, this resulting in a redundant power supply and daisy chain connection also when terminal block is not inserted in the corresponding mating connector.

The power supply is then bussed to the isolator modules by the TB.


Technical Data:

Supply: 24 Vdc nom (20 to 30 Vdc) reverse polarity protected, redundant terminal blocks, OR diodes to select higher supply source. 

Connection: by polarized plug-in disconnect screw terminal blocks to accomodate terminations up to 2.5 mm2. 

Protection fuse: 2 A time lag (spare fuse provided on Termination Board).

Fault detection: 

Supply voltage fault detection: ≤ 18 Vdc.

Fault signalling: voltage free NE SPDT relay contact (de-energized in fault condition).

Contact material: AgCdO.

Contact rating: 2 A 250 Vac 500 VA, 2 A 250 Vdc 80 W (resistive load).

Mechanical / Electrical life: 30 * 106 / 1 * 105 operation, typical.

Connection: by polarized plug-in disconnect screw terminal blocks to accomodate terminations up to 2.5 mm2.

FBM I/O card interface: 

Connection: two SUB D 25 poles male connector (requires female mating connector).

Environmental conditions: 

Operating: temperature limits -20 to + 60 °C, relative humidity max 90 % non condensing, up to 35 °C.

Storage: temperature limits – 45 to + 80 °C.

Mounting: surface mounting by four assembly slot for M6 screw. 

Shield rail connection: five holes M5x10 to connect cable screen. 

Earth connection: M4x10 screw to connect TB to earth rail. 

LED indication: green for power on, red for fault detection. 

Weight: about 960 g (excluding modules). 

Location: Safe Area/Non Hazardous Locations. 

Dimensions: Width 224 mm, Depth 190 mm, Height 122 mm.


Features:

• Two I/O card type FBM201 8 channels analog input board interface. 

• Two I/O card type FBM237 8 channels analog output board interface. 

• Two I/O card type FBM204 or FBM205 4 channels analog input plus 4 channels analog output interface.

• 8 positions Termination Board for up to 16 channels.

• Lower cables, installation and maintenance costs.

• One terminal block per input, no external terminal blocks required.

• Rugged carbon steel painted board support for easy installation.

• Shield Rail included.

• Power Supply Fault monitoring.

• Spare Fuse provided.

• Tagging provided on top side.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice
  • PULS QS40.241 Power Supply Practical Guide
  • Eaton XV-102-L Touchscreen Installation Guide
  • Omron FZ5 Vision System Selection and Configuration Guide
  • Schneider TSX47 series PLC selection
  • ABB CS31 distributed debugging
  • OMRON H8PR electronic cam debugging
  • OMRON MX2 frequency converter debugging
  • GP477R Engineering Installation
  • Siemens AS-i SlimLine Diagnostic Guidelines
  • OMRON NS Series PT Remote Access
  • OMRON Z4M sensor precision measurement
  • HIMMERWERK SINUS High Frequency Induction Heating Selection
  • OMRON CP1E PLC Practical Selection Guide
  • OMRON ZFX-C Vision Sensor in Practical Use
  • OMRON ZFV Intelligent Sensor Practical Guide
  • OMRON CJ Series PLC Practical Guide
  • Murr SIRCO Isolation Switch Selection Guide
  • OMRON ZFX Vision Sensor Engineering Practice
  • REER ULISSE UNC Security Light Curtain Practice
  • Siemens S5-90U/95U Fault Diagnosis and Advanced Programming
  • OMRON CPM2C system fault diagnosis and maintenance
  • Yaskawa ∑ - V Servo Drive Debugging Guide
  • OMRON CP1H PLC Practical Manual
  • OMRON K-type PLC Maintenance Guide
  • PEPPERL+FUCHS SLVA-4Kplus Safety Light Curtain Guide
  • Yaskawa ∑ - II Servo Drive Debugging Guide
  • Yaskawa VS-616PC5/P5 frequency converter practical application
  • OMRON 3G3SV Inverter Practical Manual
  • Pro face GP370 Complete Guide
  • OMRON FQ2 Smart Camera Selection Guide
  • Practical Guide to Sony SH800 Sorter
  • OMRON Cam Positioner Complete Guide
  • KEB F4 Inverter Debugging Guide
  • OMRON CJ series PLC operation and maintenance essentials
  • Essentials of Schneider C60H-DC DC DC Protector
  • OMRON 3G3MV Inverter Practical Guide
  • Essentials of OMRON CQM1H PLC System
  • Essentials of ARD Elevator Emergency Rescue Device
  • SolaHD SDN-D rail power supply
  • OMRON C200H PLC Troubleshooting and Programming Essentials
  • Allen Bradley 1336 PLUS Inverter Practical Guide
  • OMRON 3G3KV frequency converter
  • OMRON NSJ Integrated Controller
  • Megatiker M4 Circuit Breaker Maintenance
  • OMRON ZX laser sensor maintenance
  • Saia PCD1 Controller Maintenance Guide
  • OMRON NT Series HMI Replacement and Maintenance
  • Yaskawa F7 Driver Maintenance and Replacement
  • Rockwell 1494 switch selection replacement
  • Omron NA Series HMI Connection Guide
  • Eaton CV Series PLC System Upgrade and Diagnosis
  • Eaton XV-102 HMI Installation and Troubleshooting
  • Siemens SINUMERIK measurement cycle configuration
  • ELAU PacDrive C600 Controller Integration Guide
  • ELAU PacDrive SM Servo Motor Application and Maintenance Guide
  • Bently Nevada Orbit 60 System Upgrade and Troubleshooting Guide
  • YOKOGAWA STARDOM FCN-RTU Controller
  • Fireye InSight II Marine Flame Scanner
  • How to install ABB VSC vacuum contactor?
  • Rexroth Bosch Group VT2000 Proportional Amplifier
  • ALSTOM ALSPA series frequency converter
  • ABB SPACOM replaces REX615
  • Meggitt C327895 Gas Metering Valve Technology
  • Application of MOOG G77x servo valve
  • WOODWARD 2301E Digital Speed Controller
  • ABB UNITOL 1010/1020 AVR Compact IGBT Automatic Voltage Regulator
  • ABB UNITOL 6000 excitation system
  • Rexroth Bosch Group HNC100 Hydraulic Shaft Control
  • Lenze 8400 Inverter Debugging Guide
  • Panning Vacuum Sensor Maintenance Guide
  • SOGEVAC Rotary Disc Pump Maintenance Guide
  • THERMOVAC MEMS Vacuum Gauge Guide
  • TTR 101 Vacuum Gauge Troubleshooting Guide
  • Honeywell Beam Smoke Detector Guide
  • TURBOVAC Molecular Pump Maintenance Guide
  • Troubleshooting of Leuze electronic DDLS 200 optical transmission
  • Lam Harmonic Drive Quick Replacement Guide
  • LZS power replacement and troubleshooting
  • MTL2000 series isolation barrier
  • Temposonics GB Sensor
  • Temposonics R Series Magnetostrictive Displacement Sensor Depth
  • Original inventor of M ü ller Co ax AG coaxial valve
  • Murrelektronik Automation Solution Complete Solution
  • Nabtesco RV series high-precision gearbox
  • NACHI Robot Full Series
  • Electro hydraulic proportional directional flow valve
  • NEC FC-9801X Industrial Computer
  • Mark VIeS Security System