Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • TRICONEX 2451- Solid State Relay Output Base Board Kit
    ❤ Add to collection
  • TRICONEX 2451- Solid State Relay Output Base Board Kit

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    • ¥17267.00
      ¥18045.00
      ¥17267.00
      ¥17267.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:0.480KG
    • Quantity:
    • (Inventory: 4757)
Description


TRICONEX 2451- Solid State Relay Output Base Board Kit

2451 Solid State Relay Output Base Board Kit: An Economical and Efficient Solution for Non Critical Control Applications

In complex industrial control systems, not all output points require the highest level of triple module redundancy protection. For non critical functions such as status indication, alarm signals, and auxiliary control, simplifying the design can significantly reduce costs while maintaining reliability. The 2451 solid-state relay output base board kit of Trident system is an intelligent solution designed for such applications, providing the best balance between performance and cost for non critical control points through optimized simplex architecture and solid-state relay technology. This product is particularly suitable for applications such as alarm panels, status indicators, and auxiliary equipment interfaces, ensuring functional reliability while avoiding unnecessary redundant design costs.


Product positioning and design philosophy

The 2451 Solid State Relay Output Base Board Kit represents the embodiment of Trident's flexible design concept, specifically optimized for non safety critical applications. Unlike the triple module, 2451 adopts a simplex output design, but retains the high-quality standards and reliability characteristics of the Trident system. This differentiated design enables system architects to select appropriate output types based on the importance of each control point, optimizing the overall cost-effectiveness of the system.

This suite is mainly aimed at application scenarios that require a large number of output points but are not safety critical, such as factory status display, operator alarms, equipment operation indicators, data recording triggers, etc. In these applications, output failures do not pose safety risks or significant production losses, but reliability remains important. 2451 provides a reliability level suitable for such applications through solid-state relay technology, comprehensive diagnostic functions, and hot standby support.


System architecture and working principle

The 2451 kit is a complete relay output solution, with core components including an I/O base board (model 3000676-310), an I/O interconnect component (2921), a slot cover (2900), and a terminal cover (2901). These components together form the standard Trident I/O module installation environment.

The basic board design supports the 3451 solid-state relay output module, which adopts a non triple architecture but inherits many excellent features of the Trident system. The module receives output signals from three main processor channels and performs a two out of three vote internally. The voted data is used to drive 32 independent solid-state relays. This design ensures that even if a main processor channel fails, the output can still respond correctly.

Solid state relays are the core output components of the system and have significant advantages compared to traditional electromechanical relays: no moving parts mean longer service life and higher reliability; Fast switch response suitable for high-frequency operation; Silent operation reduces environmental noise; Resistance to vibration and impact is suitable for industrial environments. Each relay is equipped with a feedback circuit to independently verify the switch status, and functional testing can be performed without the presence of a load.


Key features and technological advantages

Optimized reliability design: Although using simplex output, the 2451 kit still provides a high level of reliability. The typical lifespan of solid-state relays can reach hundreds of millions of operations, far exceeding that of electromechanical relays. The two out of three voting within the module ensures fault tolerance at the main processor level. The comprehensive diagnostic function continuously monitors the health status of the module.

Economically efficient cost structure: By omitting the triple electronic circuit, the 2451 kit significantly reduces the cost compared to the fully triple output module. This cost advantage is particularly evident in non critical applications that require a large number of output points. Users can use the triple module in critical applications and 2451 in non critical applications to achieve the best cost-benefit balance.

Flexible output configuration: 32 output points are paired and grounded, simplifying wiring design. Output supports various types of loads, including indicator lights, alarms, small solenoid valves, contactor coils, etc. Solid state relays are suitable for applications with high switching frequencies, such as pulse output or PWM control.

Comprehensive status monitoring: Each output point has an independent feedback monitoring circuit to verify the relay status in real-time. This monitoring exists independently of the load and can perform functional testing even if the output is not connected to a device. Diagnostic information is reported to the main controller through the system bus, providing complete output status visibility.

Technical specifications and performance parameters

The dimensions of the base board comply with Trident system standards: width 7.0 inches (178 millimeters), length 9.79 inches (249 millimeters). The working environment temperature ranges from -4 ° F to+158 ° F (-20 ° C to+70 ° C), with a relative humidity of 5% -95% non condensing, suitable for typical industrial environmental conditions.

Solid state relay output specifications: rated input voltage ± 24V, operating voltage range ± 30V, maximum switch voltage ± 33V peak. The maximum rated current per channel is 0.5A, and the maximum overcurrent capacity is 0.7A. The maximum switching power is 15W (resistive load), and the off state leakage current is less than 100 μ A.

The fuse on the base board is equipped with a 0.75A quick break fuse for each output, providing overcurrent protection. The voltage drop on the base board is less than 0.25V (at 0.5A) to ensure efficient power transmission.

Isolation characteristics: minimum isolation of 500VDC between functional ground and protective ground, and minimum isolation of 800VDC between functional ground and functional ground (logic). These isolation levels ensure the electrical safety and signal integrity of the system.


Typical application scenarios

Alarm and indication system: In the control room and on-site operation station, the 2451 kit drives sound and light alarms, status indicator lights, and analog display screens. The fast response feature makes it suitable for applications that require immediate visual feedback.

Data recording and event triggering: The kit triggers data loggers, event loggers, and video surveillance systems to record critical process events. Reliable switch performance ensures accurate recording of important events.

Auxiliary equipment control: Control auxiliary equipment such as ventilation fans, lighting systems, and electric doors. The long lifespan of solid-state relays reduces maintenance requirements.

Testing and validation system: In the testing bench and validation equipment, the kit provides programmable output signals to simulate various on-site conditions. The high-frequency switching capability supports complex testing modes.

Education and Training System: In industrial automation training equipment, the 2451 kit provides secure output control, suitable for student operation and experimentation.


Installation and Configuration Guide

Install the 2451 base board following the standard Trident system installation procedure: The base board is vertically installed on the control panel, maintaining a minimum gap of 5 inches (15 centimeters) to ensure adequate heat dissipation. The installation location should avoid direct exposure to vibration, corrosive chemicals, or extreme temperature environments.

When wiring, use 24-12 AWG (0.2mm ² to 3.3mm ²) wires to connect to the compression terminals of the base board. The paired common ground design of output points simplifies wiring, but users need to pay attention to the polarity requirements of the load. For inductive loads, it is recommended to use appropriate protective circuits (such as buffer circuits) to prevent voltage spikes.

In the TriStation 1131 programming environment, the 2451 base board is configured as a standard output module. Users can set the initial state, response time, and diagnostic parameters for each output point. The configuration supports online modification, which facilitates system debugging and optimization.

The system supports hot standby module configuration, allowing for online replacement of faulty modules without shutting down. Mechanical key control design prevents incorrect installation and ensures system integrity. The module status indicator provides an intuitive display of the working status, facilitating quick fault diagnosis.


Maintenance and fault diagnosis

Preventive maintenance includes regular checks of connection status, cleaning of base board surfaces, and verification of system diagnostic functionality. It is recommended to conduct a comprehensive functional test every six months to verify the normal operation of all output points.

Fault diagnosis is achieved through the built-in diagnostic function of the system: the feedback circuit monitors the actual status of each relay and compares it with the command status to discover differences; Current monitoring detects abnormal load conditions; Temperature monitoring prevents overheating and damage. The diagnostic results are reported through the system alarm, guiding maintenance personnel to take appropriate measures.

Common troubleshooting includes: output point failure may be due to blown fuses, relay faults, or wiring issues; Abnormal load conditions may be caused by load faults or wiring errors; Communication failures may be due to connector issues or bus interference. The system provides detailed fault codes and diagnostic information, simplifying the troubleshooting process.

It is recommended to maintain an appropriate number of spare modules and fuses for spare parts management. Ensure to use the correct model and specifications when replacing components. After module replacement, functional testing should be conducted to verify that the system has resumed normal operation.


System integration and compatibility

The 2451 suite is fully integrated into the Trident system architecture and seamlessly collaborates with other modules in the system. The base board is connected to other Trident base boards through standard I/O interconnect components to form a unified I/O column. The system supports a configuration of up to 8 base boards per I/O column, and the system scale can be further expanded through I/O extender modules.

The communication with the main processor adopts the Trident system standard TMR HDLC I/O bus protocol, with a transmission rate of 2Mbps, to ensure timely execution of output commands. The system supports multiple communication protocols, including TSAA, Modbus, and TriStation Peer to Peer protocols, facilitating integration with various control systems.

For applications that require higher reliability, the system supports a hybrid configuration with triple output modules. Users can choose the most suitable module type based on the importance of each output point to achieve optimized system architecture design.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice
  • PULS QS40.241 Power Supply Practical Guide
  • Eaton XV-102-L Touchscreen Installation Guide
  • Omron FZ5 Vision System Selection and Configuration Guide
  • Schneider TSX47 series PLC selection
  • ABB CS31 distributed debugging
  • OMRON H8PR electronic cam debugging
  • OMRON MX2 frequency converter debugging
  • GP477R Engineering Installation
  • Siemens AS-i SlimLine Diagnostic Guidelines
  • OMRON NS Series PT Remote Access
  • OMRON Z4M sensor precision measurement
  • HIMMERWERK SINUS High Frequency Induction Heating Selection
  • OMRON CP1E PLC Practical Selection Guide
  • OMRON ZFX-C Vision Sensor in Practical Use
  • OMRON ZFV Intelligent Sensor Practical Guide
  • OMRON CJ Series PLC Practical Guide
  • Murr SIRCO Isolation Switch Selection Guide
  • OMRON ZFX Vision Sensor Engineering Practice
  • REER ULISSE UNC Security Light Curtain Practice
  • Siemens S5-90U/95U Fault Diagnosis and Advanced Programming
  • OMRON CPM2C system fault diagnosis and maintenance
  • Yaskawa ∑ - V Servo Drive Debugging Guide
  • OMRON CP1H PLC Practical Manual
  • OMRON K-type PLC Maintenance Guide
  • PEPPERL+FUCHS SLVA-4Kplus Safety Light Curtain Guide
  • Yaskawa ∑ - II Servo Drive Debugging Guide
  • Yaskawa VS-616PC5/P5 frequency converter practical application
  • OMRON 3G3SV Inverter Practical Manual
  • Pro face GP370 Complete Guide
  • OMRON FQ2 Smart Camera Selection Guide
  • Practical Guide to Sony SH800 Sorter
  • OMRON Cam Positioner Complete Guide
  • KEB F4 Inverter Debugging Guide
  • OMRON CJ series PLC operation and maintenance essentials
  • Essentials of Schneider C60H-DC DC DC Protector
  • OMRON 3G3MV Inverter Practical Guide
  • Essentials of OMRON CQM1H PLC System
  • Essentials of ARD Elevator Emergency Rescue Device
  • SolaHD SDN-D rail power supply
  • OMRON C200H PLC Troubleshooting and Programming Essentials
  • Allen Bradley 1336 PLUS Inverter Practical Guide
  • OMRON 3G3KV frequency converter
  • OMRON NSJ Integrated Controller
  • Megatiker M4 Circuit Breaker Maintenance
  • OMRON ZX laser sensor maintenance
  • Saia PCD1 Controller Maintenance Guide
  • OMRON NT Series HMI Replacement and Maintenance
  • Yaskawa F7 Driver Maintenance and Replacement
  • Rockwell 1494 switch selection replacement
  • Omron NA Series HMI Connection Guide
  • Eaton CV Series PLC System Upgrade and Diagnosis
  • Eaton XV-102 HMI Installation and Troubleshooting
  • Siemens SINUMERIK measurement cycle configuration
  • ELAU PacDrive C600 Controller Integration Guide
  • ELAU PacDrive SM Servo Motor Application and Maintenance Guide
  • Bently Nevada Orbit 60 System Upgrade and Troubleshooting Guide
  • YOKOGAWA STARDOM FCN-RTU Controller
  • Fireye InSight II Marine Flame Scanner
  • How to install ABB VSC vacuum contactor?
  • Rexroth Bosch Group VT2000 Proportional Amplifier
  • ALSTOM ALSPA series frequency converter
  • ABB SPACOM replaces REX615
  • Meggitt C327895 Gas Metering Valve Technology
  • Application of MOOG G77x servo valve
  • WOODWARD 2301E Digital Speed Controller
  • ABB UNITOL 1010/1020 AVR Compact IGBT Automatic Voltage Regulator
  • ABB UNITOL 6000 excitation system
  • Rexroth Bosch Group HNC100 Hydraulic Shaft Control
  • Lenze 8400 Inverter Debugging Guide
  • Panning Vacuum Sensor Maintenance Guide
  • SOGEVAC Rotary Disc Pump Maintenance Guide
  • THERMOVAC MEMS Vacuum Gauge Guide
  • TTR 101 Vacuum Gauge Troubleshooting Guide
  • Honeywell Beam Smoke Detector Guide
  • TURBOVAC Molecular Pump Maintenance Guide
  • Troubleshooting of Leuze electronic DDLS 200 optical transmission
  • Lam Harmonic Drive Quick Replacement Guide
  • LZS power replacement and troubleshooting
  • MTL2000 series isolation barrier
  • Temposonics GB Sensor
  • Temposonics R Series Magnetostrictive Displacement Sensor Depth
  • Original inventor of M ü ller Co ax AG coaxial valve
  • Murrelektronik Automation Solution Complete Solution
  • Nabtesco RV series high-precision gearbox
  • NACHI Robot Full Series
  • Electro hydraulic proportional directional flow valve
  • NEC FC-9801X Industrial Computer
  • Mark VIeS Security System
  • NI RIO Platform: Embedded Measurement and Control Solution Integrating Real time Processing and FPGA
  • NI sbRIO-9612 Single Board Controller
  • NI EPM high-performance DAQ cable
  • NI SCXI-1349 Adapter Connection Guide
  • NI SCXI Chassis Configuration and Installation Guide
  • SNAP PAC System Architecture and Selection Guide
  • PacSci Model 6410 Microstep Driver
  • TI 11kW GaN three-phase ANPC inverter
  • Pepperl+Fuchs K-System Isolation Barrier Complete Guide
  • Pacific Scientific POWERMAX II stepper motor
  • LINAK LA23 Compact Industrial Electric Push Rod
  • Pacific Scientific Servo Drive Selection Guide
  • Pacific Scientific SCE900 Servo Drive Complete Guide