  • BENTLY 3300/20 DUALTHRUST POSITION MONITOR
    ❤ Add to collection
  • BENTLY 3300/20 DUALTHRUST POSITION MONITOR

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    BENTLY 3300/20 DUALTHRUST POSITION MONITOR

    • ¥32501.00
      ¥33156.00
      ¥32501.00
      ¥32501.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:4.900KG
    • Quantity:
    • (Inventory: 42)
Description

BENTLY 3300/20 DUALTHRUST POSITION MONITOR


BENTLY 3300/20 DUALTHRUST POSITION MONITOR

DESCRIPTION

The BENTLY 3300/20 DUALTHRUST POSITION MONITOR (Bentley 3300/20 Dual Thrust Position Monitor) is a monitoring system developed by Bently Nevada, Inc. specifically designed for the continuous measurement and monitoring of the axial position of shafts in relation to the axial clearance of machines.

Main functions and features

Dual-channel monitoring: the monitor has two independent channels, capable of monitoring the same collar or two different positions of the shaft at the same time, improving the accuracy and reliability of monitoring.

Thrust Bearing Failure Detection: It is able to detect the failure of thrust bearing at an early stage, which is of great significance to ensure the safe operation of the equipment.

High-precision measurement: Measurement of thrust position is achieved by measuring the gap voltage through the proximity probe, which has high precision and stability.

False alarm protection: As sensor failures (e.g. out-of-range clearance) can be misinterpreted as thrust position movement, leading to false thrust alarms, it is recommended that two proximity probes are used for monitoring and configured for AND voting (i.e. both sensors must reach or exceed the alarm set point at the same time in order to activate the alarm relay) to prevent false alarms.

LED Indicators: Each channel is equipped with one green LED indicator and one red LED indicator to show the operational status of the monitor, sensors and field wiring as well as alarm status.

Installation and Configuration

Mounting probe: It is usually necessary to install an axial probe to directly monitor the thrust ring to ensure the accuracy of the measurement results.

Configuration Parameters: Users can configure the monitor's parameters according to actual needs, including alarm setpoints, channel selections, and so on.

Debugging and calibration: After installation and configuration, debugging and calibration are required to ensure that the monitor can work properly and accurately reflect the actual state of the equipment.

Application Scenarios

BENTLY 3300/20 DUALTHRUST POSITION MONITOR is widely used in a variety of industrial fields that require high-precision thrust position monitoring, such as power generation, petrochemical, steel and so on. It is especially suitable for those critical equipments which require very high requirements on the operation status and health condition of the equipments, such as steam turbines, compressors, etc.

Maintenance and upkeep

Regular Inspection: Regularly inspect the monitor and probe to ensure that they are in good working condition.

Cleaning and maintenance: Clean and maintain the monitor and probe to avoid the accumulation of dust and dirt affecting the measurement accuracy.

Replacement of damaged parts: If the monitor or probe is found to be damaged or malfunctioning, the damaged parts should be replaced in time to ensure the normal operation of the equipment.



  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice
  • PULS QS40.241 Power Supply Practical Guide
  • Eaton XV-102-L Touchscreen Installation Guide
  • Omron FZ5 Vision System Selection and Configuration Guide
  • Schneider TSX47 series PLC selection
  • ABB CS31 distributed debugging
  • OMRON H8PR electronic cam debugging
  • OMRON MX2 frequency converter debugging
  • GP477R Engineering Installation
  • Siemens AS-i SlimLine Diagnostic Guidelines
  • OMRON NS Series PT Remote Access
  • OMRON Z4M sensor precision measurement
  • HIMMERWERK SINUS High Frequency Induction Heating Selection
  • OMRON CP1E PLC Practical Selection Guide
  • OMRON ZFX-C Vision Sensor in Practical Use
  • OMRON ZFV Intelligent Sensor Practical Guide
  • OMRON CJ Series PLC Practical Guide
  • Murr SIRCO Isolation Switch Selection Guide
  • OMRON ZFX Vision Sensor Engineering Practice
  • REER ULISSE UNC Security Light Curtain Practice
  • Siemens S5-90U/95U Fault Diagnosis and Advanced Programming
  • OMRON CPM2C system fault diagnosis and maintenance
  • Yaskawa ∑ - V Servo Drive Debugging Guide
  • OMRON CP1H PLC Practical Manual
  • OMRON K-type PLC Maintenance Guide
  • PEPPERL+FUCHS SLVA-4Kplus Safety Light Curtain Guide
  • Yaskawa ∑ - II Servo Drive Debugging Guide
  • Yaskawa VS-616PC5/P5 frequency converter practical application
  • OMRON 3G3SV Inverter Practical Manual
  • Pro face GP370 Complete Guide
  • OMRON FQ2 Smart Camera Selection Guide
  • Practical Guide to Sony SH800 Sorter
  • OMRON Cam Positioner Complete Guide
  • KEB F4 Inverter Debugging Guide
  • OMRON CJ series PLC operation and maintenance essentials
  • Essentials of Schneider C60H-DC DC DC Protector
  • OMRON 3G3MV Inverter Practical Guide
  • Essentials of OMRON CQM1H PLC System
  • Essentials of ARD Elevator Emergency Rescue Device
  • SolaHD SDN-D rail power supply
  • OMRON C200H PLC Troubleshooting and Programming Essentials
  • Allen Bradley 1336 PLUS Inverter Practical Guide
  • OMRON 3G3KV frequency converter
  • OMRON NSJ Integrated Controller
  • Megatiker M4 Circuit Breaker Maintenance
  • OMRON ZX laser sensor maintenance
  • Saia PCD1 Controller Maintenance Guide
  • OMRON NT Series HMI Replacement and Maintenance
  • Yaskawa F7 Driver Maintenance and Replacement
  • Rockwell 1494 switch selection replacement
  • Omron NA Series HMI Connection Guide
  • Eaton CV Series PLC System Upgrade and Diagnosis
  • Eaton XV-102 HMI Installation and Troubleshooting
  • Siemens SINUMERIK measurement cycle configuration
  • ELAU PacDrive C600 Controller Integration Guide
  • ELAU PacDrive SM Servo Motor Application and Maintenance Guide
  • Bently Nevada Orbit 60 System Upgrade and Troubleshooting Guide
  • YOKOGAWA STARDOM FCN-RTU Controller
  • Fireye InSight II Marine Flame Scanner
  • How to install ABB VSC vacuum contactor?
  • Rexroth Bosch Group VT2000 Proportional Amplifier
  • ALSTOM ALSPA series frequency converter
  • ABB SPACOM replaces REX615
  • Meggitt C327895 Gas Metering Valve Technology
  • Application of MOOG G77x servo valve
  • WOODWARD 2301E Digital Speed Controller
  • ABB UNITOL 1010/1020 AVR Compact IGBT Automatic Voltage Regulator
  • ABB UNITOL 6000 excitation system
  • Rexroth Bosch Group HNC100 Hydraulic Shaft Control
  • Lenze 8400 Inverter Debugging Guide
  • Panning Vacuum Sensor Maintenance Guide
  • SOGEVAC Rotary Disc Pump Maintenance Guide
  • THERMOVAC MEMS Vacuum Gauge Guide
  • TTR 101 Vacuum Gauge Troubleshooting Guide
  • Honeywell Beam Smoke Detector Guide
  • TURBOVAC Molecular Pump Maintenance Guide
  • Troubleshooting of Leuze electronic DDLS 200 optical transmission
  • Lam Harmonic Drive Quick Replacement Guide
  • LZS power replacement and troubleshooting
  • MTL2000 series isolation barrier
  • Temposonics GB Sensor
  • Temposonics R Series Magnetostrictive Displacement Sensor Depth
  • Original inventor of M ü ller Co ax AG coaxial valve
  • Murrelektronik Automation Solution Complete Solution
  • Nabtesco RV series high-precision gearbox
  • NACHI Robot Full Series
  • Electro hydraulic proportional directional flow valve
  • NEC FC-9801X Industrial Computer
  • Mark VIeS Security System
  • NI RIO Platform: Embedded Measurement and Control Solution Integrating Real time Processing and FPGA
  • NI sbRIO-9612 Single Board Controller
  • NI EPM high-performance DAQ cable
  • NI SCXI-1349 Adapter Connection Guide
  • NI SCXI Chassis Configuration and Installation Guide
  • SNAP PAC System Architecture and Selection Guide
  • PacSci Model 6410 Microstep Driver
  • TI 11kW GaN three-phase ANPC inverter
  • Pepperl+Fuchs K-System Isolation Barrier Complete Guide
  • Pacific Scientific POWERMAX II stepper motor
  • LINAK LA23 Compact Industrial Electric Push Rod
  • Pacific Scientific Servo Drive Selection Guide
  • Pacific Scientific SCE900 Servo Drive Complete Guide