Brand:EATON
Trade name: DIL H1400 XTCEC14P ELECTRIC Contactor
Commodity number: may be different due to different sales channels and differences
Commodity type: contactor
Series: Eaton Moeller (Moeller) DILH series
Product Features
High Current Range: Designed for very high current ranges (e.g., 185 A to 2,600 A), suitable for a variety of large machines and systems.
Electronically controlled actuators: Advanced electronically controlled actuators for precise control.
Long life: Designed for long life and able to withstand extensive electrical switching operations up to 1.2 million times.
High performance: Keeping power low helps reduce heat build-up in the switchgear cabinet and extends equipment life.
Wide Voltage Range: Suitable for voltages up to 1,000 V, AC/DC wide range coils.
Global applicability: Passed UL, CSA, CCC, GL, DNV and many other international certifications, suitable for worldwide use.
Technical Specifications
Use Category: AC 1 and AC 3
Temperature range: -40°C to +70°C
Auxiliary contacts: two normally open, two normally closed
Coil holding power: Low to help reduce heat build-up
Coil voltage: May contain various specifications, such as 110V, 220V, 24V, etc., depending on model and configuration
Application Scenarios
Eaton DIL H1400 XTCEC14P ELECTRIC Contactor is suitable for a variety of industrial applications that require high current control and reliability, such as power, automation, and machinery manufacturing. Its compact design, long life and high performance characteristics make it an important component in large machines and systems.
Precautions
Instructions and warnings related to the operation of the product:
The following specifications must be strictly observed:
The technical specifications and typical applications of the product system must be strictly observed.
PERSONNEL TRAINING: Only trained personnel may install, operate, maintain or repair the product system. These personnel must be instructed on the
These personnel must be instructed and briefed on the conditions in the hazardous area.
Unauthorised modifications: No modifications or structural changes may be made to the product system.
Maintenance Responsibility: It must be ensured that the product system is only used under appropriate conditions and in a condition that is fully fit for purpose.
Working environment: The user must fulfil the specified environmental conditions:
Safety regulations
The following safety regulations must be fully observed when (maintenance) work is carried out on the product system:
1 Disconnect completely.
2 Secure to prevent reconnection.
3 Confirm that the installation has been completed.
4 Perform grounding and short-circuiting.