Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB SD822 power supply equipment
    ❤ Add to collection
  • ABB SD822 power supply equipment

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    The ABB SD822 power supply equipment is a high-performance DC switching power supply, which is an important component of ABB's industrial power product line. Its core positioning is to provide continuous and stable DC power support for sensitive electronic equipment such as industrial control circuits, automation instruments, PLC systems, relays, etc., effectively solving the impact of power grid fluctuations, voltage instability, harmonic interference and other problems on load equipment. This device adopts a modular design concept, with a compact structure and easy installation. It also has a complete protection mechanism and intelligent monitoring function, which can adapt to complex and changing industrial site environments.

    • ¥6457.00
      ¥6673.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.680KG
    • Quantity:
    • (Inventory: 99999)
Description

The ABB SD822 power supply equipment is a high-performance DC switching power supply, which is an important component of ABB's industrial power product line. Its core positioning is to provide continuous and stable DC power support for sensitive electronic equipment such as industrial control circuits, automation instruments, PLC systems, relays, etc., effectively solving the impact of power grid fluctuations, voltage instability, harmonic interference and other problems on load equipment. This device adopts a modular design concept, with a compact structure and easy installation. It also has a complete protection mechanism and intelligent monitoring function, which can adapt to complex and changing industrial site environments.




ABB SD822 power supply equipment

Basic Overview of Equipment

The ABB SD822 power supply equipment is a high-performance DC switching power supply, which is an important component of ABB's industrial power product line. Its core positioning is to provide continuous and stable DC power support for sensitive electronic equipment such as industrial control circuits, automation instruments, PLC systems, relays, etc., effectively solving the impact of power grid fluctuations, voltage instability, harmonic interference and other problems on load equipment. This device adopts a modular design concept, with a compact structure and easy installation. It also has a complete protection mechanism and intelligent monitoring function, which can adapt to complex and changing industrial site environments.


Core functional highlights

1. Stable output to ensure reliable operation of the load

The SD822 power supply equipment has excellent voltage stabilization accuracy and ripple suppression capability. Even in the case of significant input voltage fluctuations (such as ± 15% grid fluctuations), it can output DC voltage with an accuracy of up to ± 0.5% and a ripple factor of less than 1%, effectively avoiding the interference of voltage fluctuations on sensitive electronic devices, ensuring that the signal acquisition and control instruction execution of PLC, sensors and other equipment are not affected, and reducing the risk of equipment misoperation.

2. Improve protection mechanisms to enhance system security

To cope with various unexpected situations on industrial sites, the equipment integrates multiple protection functions, including:

-Overcurrent protection: When the output current exceeds the rated value, the equipment automatically enters a current limiting state or stops for protection, avoiding damage to the equipment caused by load short circuit or overload;

-Overvoltage protection: If the output voltage rises abnormally, the protection circuit will quickly start, cut off the output or limit the voltage to prevent the load equipment from being broken down by high voltage;

-Over temperature protection: The device is equipped with a temperature sensor inside. When the temperature of the core components exceeds the threshold, it automatically reduces the output power or shuts down to avoid overheating damage;

-Input undervoltage/overvoltage protection: In case of abnormal grid voltage, the equipment can respond quickly to ensure its own and load safety.

3. Intelligent monitoring and remote management

The SD822 power supply equipment supports multiple monitoring methods, and some models are equipped with LCD displays that can display key parameters such as input voltage, output voltage, output current, and equipment temperature in real time, making it convenient for on-site operation and maintenance personnel to intuitively grasp the equipment's operating status. At the same time, the device provides RS485 communication interface, supports industrial communication protocols such as Modbus, and can be connected to industrial automation control systems or remote monitoring platforms to achieve remote start stop, parameter configuration, fault alarm and other functions of power equipment, reducing operation and maintenance costs and improving management efficiency.

4. Modular design for easy expansion and maintenance

The equipment adopts a standardized modular structure, with each functional module independently designed for easy replacement. When it is necessary to expand the power capacity, multiple SD822 modules can be connected in parallel to achieve redundant backup or capacity expansion, improving the reliability of system power supply; When a module fails, it can be replaced without stopping the machine, greatly shortening the fault handling time and reducing production interruption losses.


Key technical parameters

Input voltage range

AC 110V/220V (wide range input, some models support AC 85-264V)

output voltage

DC 24V (regular model), adjustable according to needs (such as 12V, 48V)

Rated output current

20A (typical value, different models cover the range of 10A-50A)

voltage regulation accuracy

± 0.5% (static), ± 1% (dynamic)

efficiency

≥ 90% (under full load)

Working temperature range

-20 ℃~60 ℃ (wide temperature models support -40 ℃~70 ℃)

Protection level

IP20 (panel installation), IP65 (outdoor or harsh environment models)

communication interface

RS485 (supporting Modbus RTU protocol)

Dimensions (width x height x depth)

Approximately 100mm x 150mm x 200mm (depending on the model)


Applicable scenarios

With stable performance and rich features, ABB SD822 power equipment is widely used in the following fields:

1. In the field of industrial automation: providing DC power supply for PLC control systems, DCS distributed control systems, industrial robots, sensors, actuators and other equipment in automated production lines to ensure the continuous and stable automation production process;

2. In the field of power systems: used for relay protection devices, monitoring systems, instrument equipment, etc. in substations and distribution rooms to ensure the safe operation and precise scheduling of the power system;

3. Data center field: Provide power support for auxiliary control circuits of IT equipment such as servers, storage devices, network switches, etc., to improve the reliability of data center power supply;

4. Transportation field: signal systems, monitoring equipment, and control modules for new energy vehicle charging stations applied to rail transit;

5. Medical equipment field: Provide stable power supply for auxiliary circuits of some medical diagnostic equipment and monitoring equipment, meeting the high requirements of medical equipment for power supply accuracy and reliability.


Product advantages and features

1. Brand guarantee, reliable quality

ABB has a hundred years of experience in the research and manufacturing of power equipment. SD822 power equipment strictly follows international quality standards and undergoes rigorous environmental testing, lifespan testing, and reliability testing. The product has a low failure rate and a service life of over 100000 hours, making it suitable for long-term continuous operation in industrial scenarios.

2. Efficient and energy-saving, reducing costs

The equipment adopts advanced switching power supply technology, with a full load efficiency of over 90%. Compared with traditional linear power supplies, it has lower energy consumption and can effectively reduce the electricity cost of enterprises; At the same time, efficient and energy-saving design also reduces the heat dissipation requirements of equipment and extends the service life of internal components.

3. Strong environmental adaptability

The SD822 power supply equipment has the characteristics of wide temperature and wide input voltage range, and can adapt to complex industrial site environments such as high temperature, low temperature, and frequent power grid fluctuations; Some models have high protection levels and can operate stably in harsh environments such as dust and humidity.

4. High usability and convenient operation and maintenance

The equipment adopts a standardized guide rail installation method, which is easy to install and disassemble; Intuitive parameter display and clear fault alarm indication make it easy for operation and maintenance personnel to quickly locate problems; Supporting remote monitoring function reduces the workload of on-site inspections and improves operation and maintenance efficiency.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Alcatel 1660SM Multi Service Node Operations and Troubleshooting
  • Alcatel Lucent OmniSwitch 6850 Stacking and Security Configuration Guide
  • Alcatel Lucent 7750 SR Router High Availability Deployment and Troubleshooting
  • Alcatel 1600 Series SDH Equipment Operation and Maintenance Guide
  • Alcatel Lucent 9500 MPR Microwave Platform Deployment and Troubleshooting
  • Alcatel Lucent 7450 ESS High Availability Deployment and Operations Guide
  • Alcatel OmniPCX 4400 REFLEXES Phone Configuration Troubleshooting
  • Alcatel Lucent OmniSwitch 6850E Stacking Operations and Troubleshooting
  • Alcatel Lucent OmniSwitch 6450 Stacking and Troubleshooting Guide
  • Lucent Stinger DSLAM High Availability Deployment and Fault Recovery Complete Guide
  • Alcatel Lucent 1660SM Optical Transmission System Architecture and Business Bearer
  • ALCATEL-LUCENT 9500 MPR Microwave Packet Wireless System Performance
  • Atlas Copco MT Focus 6000 Controller Safety Specification and Electrical Grounding
  • Atlas Copco Power MACS 4000 Automated Tightening System Performance
  • Design and Protection of Constant Torque Application for Atlas Copco Neos Inverter
  • Atlas Copco Power Focus 8 Family Selection Configuration and Virtual Station Function Complete Explanation
  • Atlas Copco Power Focus 4000 Controller Safety Deployment and Electrical Grounding Specification
  • Atlas Copco Power Focus 3000 Controller Installation, Debugging, and Troubleshooting Guide
  • Atlas Copco Tensor S Tightening Tool Troubleshooting Guide
  • Application and maintenance of Atlas Copco SRTT-B torque sensor
  • Atlas Copco ACTA 4000 Torque Analyzer Operation and Calibration Guide
  • Atlas Copco Tensor STB Wireless Tightening Tool Deployment Guide
  • Atlas Copco Power Focus 4000 Configuration and Troubleshooting Manual
  • Atlas Copco Power Focus 6000 and Tensor STR System
  • Energy efficiency and selection of Atlas Copco ZR/ZT oil-free screw compressor
  • Atlas Copco PowerMACS 4000 Tightening Control System
  • Atlas Copco Elektronikon MK5 Controller Operation Guide
  • Atlas Copco Tensor ES and PF600 Tightening System
  • ADLINK STC2-AL/KL Industrial Control Tablet BIOS and Drivers
  • ADLINK STC-15W04 industrial tablet computer
  • ADLINK SP2-EHL Fanless Tablet Selection and Configuration Guide
  • ADLINK PXIS-2719A Chassis Deployment Monitoring Guide
  • ADLINK PXIe-9908 SMU Deployment and Configuration Guide
  • ADLINK PXIe-9852 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9848 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9834 High Speed Digitizer Configuration Guide
  • ADLINK PXIe-9529H Dynamic Signal Acquisition Configuration Guide
  • ADLINK PXIe-3988 Xeon Deployment Optimization Guide
  • ADLINK PXIe-3987/3977/3937 Deployment and Debugging
  • ADLINK PXIe-3987 Installation and Configuration Programming Guide
  • ADLINK-PXIe-3988-3987-3977-3937-TL Controller Deployment and Maintenance Guide
  • ADLINK PXI-2020/2022 Synchronous Acquisition Card Configuration and Synchronization Guide
  • ADLINK DAQ/PXI-2000 series synchronous acquisition card configuration and triggering
  • ADLINK PXES-2788 series chassis deployment and maintenance
  • ADLINK PXES-2785 18 Slot Gen3 Chassis Deployment and Maintenance Guide
  • ADLINK PXES-2780 18 Slot PXIe Chassis Deployment Configuration
  • ADLINK PXES-2596 Gen3 Chassis Installation and Maintenance Guide
  • ADLINK PXES-2590 Chassis Deployment and System Management
  • ADLINK PXES-2314T Chassis Deployment and Troubleshooting Guide
  • ADLINK PXES-2301 Chassis Installation Monitoring and Troubleshooting
  • ADLINK PCIe-U300 Series USB3 Vision Acquisition Card Deployment Guide
  • ADLINK PCIe PXIe-8565 Expansion Kit Remote Control and Compatibility
  • Installation and troubleshooting of ADLINK PCIe GIE74V four channel PoE acquisition card
  • ADLINK PCIe GIE7x Poe+Acquisition Card Configuration and Triggering Troubleshooting
  • Advanced triggering and multi card synchronization of ADLINK PCIe-CPL64V image acquisition card
  • ADLINK PCIe-CPL64 Image Acquisition Card Hardware Trigger and Encoder Application
  • Application and troubleshooting of ADLINK PCIe-8560/PXI-8565 expansion kit
  • ADLINK PCIe 8332/PCIe 8334/PCIe 8338 EtherCAT Motion Controller Multi axis Synchronous Control
  • ADLINK PCIe-7432 32 channel isolated I/O card interrupt and driver
  • ADLINK PCIe-7256 Industrial I/O Card Interruption and Relay
  • ADLINK PCIe-833x EtherCAT Motion Controller Debugging and Maintenance
  • ADLINK PCIe-10GPoE 10GigE Visual Acquisition Card Practical Use
  • ADLINK PCI-8254/8258 Motion Controller Debugging and Maintenance
  • Application and Maintenance of ADLINK PCI-8158 Multi axis Motion Control Card
  • ADLINK PCI-8134A Maintenance and Troubleshooting Guide
  • ADLINK PCI-7250 Series Relay Output Card Configuration and Protection Circuit Guide
  • ADLINK PCI-6308 Series Isolated Analog Output Card Configuration and Programming
  • ADLINK PanKonix Series HMI Panel Selection and Deployment Guide
  • ADLINK NuDAM-6100 Series I/O Module Deployment and Protocol Optimization
  • Deployment and Calibration of ADLINK NuDAM-6000 Data Acquisition Module
  • ADLINK NEON-2000-Ono Intelligent Camera Deployment and Trigger Optimization
  • ADLINK NuDAM-65xx Communication Module Networking and Configuration Guide
  • ADLINK NuDAM-60xx Series Digital I/O Module Deployment and Watchdog Optimization
  • ADLINK MXE-5300 Fanless Industrial Control Computer Deployment and Troubleshooting Manual
  • ADLINK MXE-310 edge computing Platform Hardware Installation and BIOS Tuning
  • ADLINK MXE-230 series Alder Lake platform industrial computer deployment and maintenance manual
  • ADLINK MXE-210 Compact Fanless Industrial Control Computer Hardware Deployment and Debugging Guide
  • ADLINK MXC-3300/3340 Embedded Industrial Control Computer Hardware Integration and Debugging Manual
  • ADLINK MXA-312M Edge AI Platform Hardware Integration and Debugging Guide
  • ADLINK MXA-200 IoT Gateway Hardware Installation and Linux System Debugging Complete Guide
  • ADLINK MVP-6200 Industrial Control Computer: PCIe Gen4 and PCI Hybrid Expansion
  • ADLINK MVP-6100 Industrial Control Computer: PCI/PCIe Expansion and Robust Design
  • ADLINK MVP-5200 Industrial Control Computer: High Performance Multi Display and TSN Network
  • ADLINK MVP-5100 Fanless Industrial Control Computer Deployment and Development Guide
  • ADLINK MVP-3100 and MVP-3120 Embedded Systems
  • ADLINK MNET-J3/S23/MIA/DA2/SAN Single Axis Module Installation and Wiring Guide
  • ADLINK MNET-4XMO/C Motion Module Installation and Debugging Guide
  • ADLINK MCM-216/218 Edge DAQ Deployment Configuration Guide
  • ADLINK LPCIe-8124-C Encoder Card Trigger Configuration Guide
  • ADLINK IM/OM Series Industrial Display Installation and Debugging Guide
  • ADLINK GW-01 Industrial IoT Gateway Configuration and Debugging Guide
  • EURESYS Grablink Collection Card Selection and Trigger Configuration Guide
  • ADLINK Express HL Module Selection and Heat Dissipation Configuration Guide
  • ADLINK EOS-2000 Visual System Installation and Troubleshooting
  • ADLINK EOS-1200 Installation, Configuration, and Troubleshooting
  • Application and Configuration of ADLINK ECS-8582-4S Extension System
  • ADLINK DIN-814P-A4 Panasonic servo adapter board configuration
  • ADLINK DIN-814M-J3A Mitsubishi servo adapter board configuration
  • ADLINK DIN-814-GP Universal Adapter Board Configuration
  • Application and Configuration of ADLINK DIN-812M Adapter Board
  • Application and Configuration of ADLINK DIN-814Y Adapter Board
  • ADLINK DAQ/DAQE/PXI-250x waveform generation complete guide
  • ADLINK DAQ/DAQE/PXI-220x acquisition card fully configured
  • Application and Configuration of ADLINK cPCI-9116 Data Acquisition Card
  • ADLINK cPCI/PCI-8554/R: A Complete Guide from Architecture to Application
  • ADLINK cPCI-7432/7433/7434 isolated I/O card
  • ADLINK cPCI-3544/3534/3538 Serial Cardcard Configuration Practice
  • ADLINK cPCI-3534/3538/3544 Multi Serial Port Card Configuration Complete Solution
  • Complete Technical Guide for Euresys Coaxlink CXP Capture Card
  • ADLINK AMP-304C Advanced Motion Control Card Complete Guide
  • ADLINK AMP-104C Four Axis Motion Control Card
  • ADLINK NEON-1020/1040 Smart Camera
  • ADLINK USB-7230/7250 Isolation I/O Module Operation Manual
  • ADLINK SP-15W03 Intelligent Panel Integration and Configuration Manual
  • ADLINK AMP-20xC Interface Configuration and Wiring Guide
  • ADLINK 3488A GPIB Interface Card Selection Guide
  • Complete solution of ETEL TMB+torque motor selection parameters
  • ADLINK RTV series frame grabber deployment guide
  • ADLINK PCIe-FIW64/62 Image Acquisition Card Configuration Guide
  • ADLINK 6208/6216-GL Analog Output Card
  • ADLINK 723X Isolation I/O Card Configuration Guide
  • ADLINK PCI-9118 series high-speed DAQ card selection and DMA configuration
  • ADLINK PCI-9114 (A) Data Acquisition Card Selection and Configuration Guide
  • ADLINK PCI-7442/7443/7444 Isolation I/O Card Selection and Safety Configuration
  • ADLINK PCI-7250/7251 Relay Output Card Selection and Expansion Guide
  • Selection and Protection Configuration of Advantech PCI-1610CU Multi Serial Port Card
  • ADLINK NEON-1000-MDX Smart Camera Deployment and Trigger Configuration
  • ADLINK MXE-1300 Industrial Control Computer Selection and Deployment Guide