Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • TRICONEX 2401- Digital Output Base Board Kit
    ❤ Add to collection
  • TRICONEX 2401- Digital Output Base Board Kit

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    • ¥6057.00
      ¥8357.00
      ¥6057.00
      ¥6057.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:0.480KG
    • Quantity:
    • (Inventory: 6847)
Description

2401 Digital Output Basic Board Kit: A High Reliability Output Solution for Safety Critical Control Applications

In industrial process control and safety systems, the reliability of output signals is directly related to equipment safety and production continuity. The 2401 digital output base board kit of Trident system is an output solution designed specifically for high reliability control applications. Through innovative quadruple voting circuits and comprehensive diagnostic functions, it provides users with industry-leading output reliability and safety.


Product Overview and Positioning

The 2401 basic board kit is an important component of Trident's triple module redundancy system and is fully compatible with the 3401 digital output module. This kit is designed to drive on-site actuators such as solenoid valves, motor starters, alarms, etc. It plays a core role in safety critical applications such as petrochemicals, power systems, and emergency parking systems.

As the standard digital output component of the Trident system, the 2401 base board follows strict safety standards, including IEC 61508 functional safety standards and Factory Mutual hazardous area certification. Its design philosophy is to achieve the highest level of security without sacrificing usability, which runs through every detail from circuit design to diagnostic algorithms.


Key features and advantages

The most significant feature of the 2401 basic board is the use of patented quadruple voting circuit design. This circuit is based on the parallel series path principle, and power is only transmitted when two of the three switches (channels A and B, or channels B and C, or channels A and C) are simultaneously commanded to close. This design provides multiple redundancies on all critical signal paths, ensuring safe operation even in the event of multiple faults.

Comprehensive output diagnosis: The basic board supports output voting diagnosis (OVD) routine programs, which can regularly detect various fault situations. This diagnosis can detect all point jamming (normally open or normally closed) faults, as well as all switch or its related drive circuit jamming faults within 500 milliseconds. This comprehensive fault coverage ensures the safe response of the system in any abnormal situation.

Classification fault tolerance: In normal operation mode, each output point supports a self limiting current of up to 4.8A (typical value 3.0A); In degraded mode, it can still provide a self limiting current greater than 0.7A (typical value 1.5A). This hierarchical design ensures that the system can maintain basic functionality and maximize availability in the event of partial failures.

On site alarm function: The basic board integrates on-site alarm circuits, which can detect abnormal situations such as power loss and output point short circuit (open or closed) on site, and notify operators in a timely manner through system alarms to prevent the fault from expanding.

Detailed explanation of technical specifications

The 2401 base board kit includes the following core components: an I/O base board (model 3000674-030), an I/O interconnect component (2921), a slot cover (2900), and a terminal cover (2901). These components provide a complete installation solution and simplify the on-site deployment process.

The dimensions of the base board comply with Trident system standard I/O specifications: width 7.0 inches (178 millimeters), length 9.79 inches (249 millimeters), compatible with other components of the system, facilitating cabinet layout and installation planning.

In terms of electrical characteristics, the base board supports a working voltage range of 15-30VDC, with a rated voltage of 24VDC and an absolute maximum output voltage of 33VDC. The output characteristics include: on state voltage drop less than 1.0VDC (@ 1.5A), off state leakage current less than 1mA, ensuring efficient power transmission and minimum power consumption.

In terms of diagnostic function, the duration of diagnostic glitches is less than 2ms (maximum value, typical value 500 μ s), and the minimum switching cycle supported by diagnostic fault coverage is greater than 20ms. The loop scanning time is less than 1.0ms (all 16 points) to ensure fast fault detection and system response.

Isolation performance is a key indicator of safety systems. The 2401 base board provides a minimum isolation of 500VDC between functional ground and protective ground, as well as a minimum isolation of 800VDC between functional ground and logical ground, ensuring the electrical safety and signal integrity of the system.


Typical application scenarios

Emergency stop system: In petrochemical plants, the 2401 foundation board is used to drive emergency shut-off valves and critical equipment shutdown circuits, ensuring fast and reliable execution of safety actions in dangerous situations.

Fire and explosion prevention system: In flammable environments, this foundation board controls safety devices such as fire extinguishing system release valves and explosion-proof ventilation equipment to provide protection for personnel and equipment.

Key process control: In the continuous production process, the 2401 base board drives key regulating valves and pump control circuits to ensure stable control of process parameters.

Alarm and indication system: The base board is used to drive the sound and light alarm and on-site status indicator lights in the control room, providing clear process status information for operators.


Installation and Configuration Guide

When installing the 2401 base board, it is necessary to ensure that the environmental conditions meet the Trident system requirements: ambient temperature -4 ° F to+158 ° F (-20 ° C to+70 ° C), relative humidity 5% -95% non condensing. The base board should be installed vertically, maintaining a gap of at least 5 inches (15 centimeters) to ensure sufficient heat dissipation and ventilation.

When wiring, 24-12 AWG (0.2mm ² to 3.3mm ²) wires should be used and correctly connected to the compression terminals of the base board. For high voltage applications or hazardous areas, it can be used in conjunction with external wiring panels, such as relay output external wiring panels or 9671-610 DO hazardous area external wiring panel kits.

In terms of configuration, the base board supports left/right module slot configuration, with the left module corresponding to the slot below the "L" label and the right module corresponding to the slot below the "R" label. The system supports hot standby configuration, allowing for online replacement of faulty modules without the need for system shutdown. Mechanical key control design prevents incorrect installation and ensures system reliability.


Security features and authentication

The 2401 basic board design meets the highest level of safety requirements, and its quadruple voting circuit provides a 2oo3 (two out of three) voting mechanism to ensure that a single fault will not cause misoperation. The self limiting characteristic of the output circuit prevents overcurrent damage, while the comprehensive diagnostic function ensures that faults can be detected and alarmed in a timely manner.

In terms of certification, the 2401 base board has obtained multiple international certifications: certified by the Canadian Standards Association (CSA) and compliant with CAN/CSA-C22.2 standards; Obtain the EU CE mark and comply with the IEC 61131-2 standard; Certified by T Ü V Rheinland and compliant with standards such as EN50156-1:2004; Obtained Factory Mutual certification, suitable for Class I, Division 2 hazardous areas.

These certifications ensure the compliance and interoperability of the 2401 base board globally, allowing users to deploy it with confidence in various industrial environments and applications.


System integration and compatibility

The 2401 base board is fully compatible with the Trident system architecture and is connected to other Trident base boards through I/O interconnect components to form a unified I/O column. Each I/O column can connect up to 8 base boards, and the system scale can be further expanded through I/O extender modules.

This base board supports TMR HDLC I/O bus communication with Trident main processor modules, with a transmission rate of up to 2Mbps, ensuring real-time and reliable control commands. Meanwhile, it is compatible with the TriStation 1131 programming environment and supports user-defined output logic and diagnostic strategies.

For special application requirements, the Trident system also offers a 2401L low current version of the base board kit, which integrates a 180 ohm series resistor on each output and provides additional current limiting protection, suitable for applications with special requirements for current limiting.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice
  • PULS QS40.241 Power Supply Practical Guide
  • Eaton XV-102-L Touchscreen Installation Guide
  • Omron FZ5 Vision System Selection and Configuration Guide
  • Schneider TSX47 series PLC selection
  • ABB CS31 distributed debugging
  • OMRON H8PR electronic cam debugging
  • OMRON MX2 frequency converter debugging
  • GP477R Engineering Installation
  • Siemens AS-i SlimLine Diagnostic Guidelines
  • OMRON NS Series PT Remote Access
  • OMRON Z4M sensor precision measurement
  • HIMMERWERK SINUS High Frequency Induction Heating Selection
  • OMRON CP1E PLC Practical Selection Guide
  • OMRON ZFX-C Vision Sensor in Practical Use
  • OMRON ZFV Intelligent Sensor Practical Guide
  • OMRON CJ Series PLC Practical Guide
  • Murr SIRCO Isolation Switch Selection Guide
  • OMRON ZFX Vision Sensor Engineering Practice
  • REER ULISSE UNC Security Light Curtain Practice
  • Siemens S5-90U/95U Fault Diagnosis and Advanced Programming
  • OMRON CPM2C system fault diagnosis and maintenance
  • Yaskawa ∑ - V Servo Drive Debugging Guide
  • OMRON CP1H PLC Practical Manual
  • OMRON K-type PLC Maintenance Guide
  • PEPPERL+FUCHS SLVA-4Kplus Safety Light Curtain Guide
  • Yaskawa ∑ - II Servo Drive Debugging Guide
  • Yaskawa VS-616PC5/P5 frequency converter practical application
  • OMRON 3G3SV Inverter Practical Manual
  • Pro face GP370 Complete Guide
  • OMRON FQ2 Smart Camera Selection Guide
  • Practical Guide to Sony SH800 Sorter
  • OMRON Cam Positioner Complete Guide
  • KEB F4 Inverter Debugging Guide
  • OMRON CJ series PLC operation and maintenance essentials
  • Essentials of Schneider C60H-DC DC DC Protector
  • OMRON 3G3MV Inverter Practical Guide
  • Essentials of OMRON CQM1H PLC System
  • Essentials of ARD Elevator Emergency Rescue Device
  • SolaHD SDN-D rail power supply
  • OMRON C200H PLC Troubleshooting and Programming Essentials
  • Allen Bradley 1336 PLUS Inverter Practical Guide
  • OMRON 3G3KV frequency converter
  • OMRON NSJ Integrated Controller
  • Megatiker M4 Circuit Breaker Maintenance
  • OMRON ZX laser sensor maintenance
  • Saia PCD1 Controller Maintenance Guide
  • OMRON NT Series HMI Replacement and Maintenance
  • Yaskawa F7 Driver Maintenance and Replacement
  • Rockwell 1494 switch selection replacement
  • Omron NA Series HMI Connection Guide
  • Eaton CV Series PLC System Upgrade and Diagnosis
  • Eaton XV-102 HMI Installation and Troubleshooting
  • Siemens SINUMERIK measurement cycle configuration
  • ELAU PacDrive C600 Controller Integration Guide
  • ELAU PacDrive SM Servo Motor Application and Maintenance Guide
  • Bently Nevada Orbit 60 System Upgrade and Troubleshooting Guide
  • YOKOGAWA STARDOM FCN-RTU Controller
  • Fireye InSight II Marine Flame Scanner
  • How to install ABB VSC vacuum contactor?
  • Rexroth Bosch Group VT2000 Proportional Amplifier
  • ALSTOM ALSPA series frequency converter
  • ABB SPACOM replaces REX615
  • Meggitt C327895 Gas Metering Valve Technology
  • Application of MOOG G77x servo valve
  • WOODWARD 2301E Digital Speed Controller
  • ABB UNITOL 1010/1020 AVR Compact IGBT Automatic Voltage Regulator
  • ABB UNITOL 6000 excitation system
  • Rexroth Bosch Group HNC100 Hydraulic Shaft Control
  • Lenze 8400 Inverter Debugging Guide
  • Panning Vacuum Sensor Maintenance Guide
  • SOGEVAC Rotary Disc Pump Maintenance Guide
  • THERMOVAC MEMS Vacuum Gauge Guide
  • TTR 101 Vacuum Gauge Troubleshooting Guide
  • Honeywell Beam Smoke Detector Guide
  • TURBOVAC Molecular Pump Maintenance Guide
  • Troubleshooting of Leuze electronic DDLS 200 optical transmission
  • Lam Harmonic Drive Quick Replacement Guide
  • LZS power replacement and troubleshooting
  • MTL2000 series isolation barrier
  • Temposonics GB Sensor
  • Temposonics R Series Magnetostrictive Displacement Sensor Depth
  • Original inventor of M ü ller Co ax AG coaxial valve
  • Murrelektronik Automation Solution Complete Solution
  • Nabtesco RV series high-precision gearbox
  • NACHI Robot Full Series
  • Electro hydraulic proportional directional flow valve
  • NEC FC-9801X Industrial Computer
  • Mark VIeS Security System
  • NI RIO Platform: Embedded Measurement and Control Solution Integrating Real time Processing and FPGA
  • NI sbRIO-9612 Single Board Controller
  • NI EPM high-performance DAQ cable
  • NI SCXI-1349 Adapter Connection Guide
  • NI SCXI Chassis Configuration and Installation Guide
  • SNAP PAC System Architecture and Selection Guide
  • PacSci Model 6410 Microstep Driver
  • TI 11kW GaN three-phase ANPC inverter
  • Pepperl+Fuchs K-System Isolation Barrier Complete Guide
  • Pacific Scientific POWERMAX II stepper motor
  • LINAK LA23 Compact Industrial Electric Push Rod
  • Pacific Scientific Servo Drive Selection Guide
  • Pacific Scientific SCE900 Servo Drive Complete Guide