Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • TRICONEX 2401L - Low Current Digital Output Base Board Kit
    ❤ Add to collection
  • TRICONEX 2401L - Low Current Digital Output Base Board Kit

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    • ¥7272.00
      ¥7837.00
      ¥7272.00
      ¥7272.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:0.210KG
    • Quantity:
    • (Inventory: 6845)
Description

TRICONEX 2401L - Low Current Digital Output Base Board Kit

2401L Low Current Digital Output Base Board Kit: Professional Current Limiting Solution for Intrinsic Safety Applications

In the field of industrial control, especially in hazardous environments such as chemical engineering, oil and gas, the current limitation of output circuits is not only a requirement for equipment protection, but also a key requirement for intrinsic safety design. The 2401L low current digital output base board kit of Trident system is a professional solution designed for such special needs. By integrating current limiting resistors and optimizing circuit design, it provides safe and reliable control means for sensitive loads and hazardous area applications.


Product Overview and Positioning

The 2401L base board kit is a professional version of Trident's digital output product line, designed specifically for specific application scenarios that require built-in current limiting functionality. Compared to the standard 2401 base board, the 2401L integrates 180 ohm series resistors on each output channel, providing additional current limiting protection, making it particularly suitable for driving low-power loads or applications that require intrinsic safety considerations.

This product is mainly aimed at industries such as petrochemicals, pharmaceutical production, and fine chemicals, which often have strict restrictions on the current and energy of control circuits to prevent flammable gas or dust explosions caused by electric sparks. The design of 2401L fully considers these special requirements, while maintaining the high reliability and safety of Trident system, adding current limiting function and expanding the applicability of the system.


Key features and advantages

Integrated current limiting protection: The most significant feature of the 2401L base board is the integration of 180 ohm series resistors on each output channel. This design limits the maximum current of the output circuit, and even in the event of an output short circuit fault, it can control the current within a safe range to prevent overcurrent damage and spark generation.

Intrinsic safety enhancement: By limiting output current and energy, the 2401L base board reduces the risk of circuit ignition, making it particularly suitable for applications that require intrinsic safety design. This feature makes it an ideal choice for hazardous area control applications, reducing reliance on external safety barriers.

Compatible with standard DO module: Despite the addition of current limiting function, the 2401L base board is still fully compatible with the standard 3401 digital output module, without the need for special modules or additional configurations. This backward compatibility protects users' existing investments and simplifies system upgrades and maintenance.

Maintain core security features: The 2401L base board inherits all the security features of standard 2401, including patented quadruple voting circuits, comprehensive output diagnostics, on-site alarm functions, and more. The addition of current limiting function not only does not sacrifice these core safety functions, but also enhances the overall safety of the system.

Detailed explanation of technical specifications

The 2401L base board kit includes the following core components: a dedicated I/O base board (model 3000659-130), an I/O interconnect component (2921), a slot cover (2900), and a terminal cover (2901). These components provide a complete installation solution, ensuring the ease of deployment and maintenance of the system.

The physical dimensions of the base board are consistent with the Trident system standard I/O base board: width 7.0 inches (178 millimeters), length 9.79 inches (249 millimeters). This standardized design ensures compatibility with existing system cabinets and installation hardware, simplifying the system integration process.

In terms of electrical characteristics, the working voltage range of the 2401L base board is the same as the standard version, supporting 15-30VDC, rated voltage 24VDC, and absolute maximum output voltage 33VDC. Due to the addition of series resistance, the output characteristics have been adjusted: the maximum output current is limited by the resistance, and the output power capability is correspondingly reduced.

The parameter of the current limiting resistor is 180 ohms, and the rated power design considers the worst-case power consumption. The resistor adopts high-quality industrial grade components with stable temperature characteristics and long-term reliability, ensuring stable limiting characteristics throughout the entire operating temperature range.

In terms of isolation performance, the 2401L base board provides the same isolation level as the standard version: a minimum isolation of 500VDC between functional ground and protective ground, and a minimum isolation of 800VDC between functional ground and logical ground. These isolations ensure the electrical safety and signal integrity of the system, protecting personnel and equipment even in the event of a malfunction.


Typical application scenarios

Inherent safety zone control: In the chemical and petroleum industries, the 2401L foundation board is used to drive low-power sensors, indicators, and alarm devices, meeting strict energy limitation requirements.

Low power load drive: In applications that require driving low-power relays, indicator lights, or small solenoid valves, the current limiting function of the base board provides additional protection against overcurrent problems caused by load faults.

Laboratory and testing equipment: In research institutions and testing laboratories, the 2401L base board provides controlled output signals for precision testing equipment, and the current limiting function prevents accidental overload damage to sensitive equipment.

Education and training system: In the industrial automation training system, the current limiting function of the base board provides additional safety assurance, suitable for student operation and experimental environment.

Medical equipment control: In medical equipment manufacturing and control systems, the 2401L base board provides safe control signals for sensitive medical equipment, and current limiting ensures compliance with medical electrical safety standards.


Installation and Configuration Guide

When installing the 2401L base board, it is necessary to follow the general installation specifications of the Trident system: the ambient temperature should be maintained within the range of -4 ° F to+158 ° F (-20 ° C to+70 ° C), and the relative humidity should be 5% -95% non condensing. The base board should be installed vertically on the control panel, maintaining a gap of at least 5 inches (15 centimeters) to ensure sufficient heat dissipation.

When wiring, appropriate wire specifications (24-12 AWG, 0.2mm ² to 3.3mm ²) should be used and correctly connected to the compression terminals of the base board. Due to the addition of a series resistor, users should consider the voltage drop effect of the resistor when selecting a load to ensure that the load operates normally within the available voltage range.

In terms of configuration, the 2401L base board supports standard Trident system configuration tools and methods. In the TriStation 1131 programming environment, the base board is configured and managed as a standard digital output module without the need for special programming or parameter settings. This transparency simplifies engineering design and system maintenance work.

The base board supports hot standby module configuration, allowing for online replacement of faulty modules without the need for system shutdown. The mechanical key control design ensures that only compatible modules can be installed correctly, preventing system failures caused by human operation errors.


Safety design and certification considerations

The design of the 2401L base board fully considers the special requirements for intrinsic safety applications. The selection of current limiting resistors is based on worst-case analysis to ensure that the energy of the output circuit is controlled within a safe range in any fault mode. The circuit design also includes appropriate heat dissipation measures to prevent the resistor from overheating during prolonged operation or fault conditions.

In terms of certification, the 2401L base board inherits various international certifications from Trident system, including Canadian Standards Association (CSA) certification, EU CE mark, T Ü V Rheinland certification, and Factory Mutual certification. For specific intrinsic safety applications, users can consult the manufacturer for detailed certification information and scope of application.

The safety function design of the base board follows the principle of "fail safe": when a system failure is detected, the output will enter a predefined safety state (usually a shutdown state) to prevent dangerous situations caused by misoperation. The Output Voting Diagnosis (OVD) routine regularly verifies the health status of the output circuit to ensure that faults can be detected and addressed in a timely manner.


System integration and compatibility

The 2401L base board is fully compatible with the Trident system architecture and can be connected to other Trident base boards through I/O interconnect components to form a unified I/O column. The system supports up to 8 base boards per I/O column, and the system scale can be further expanded through I/O extender modules.

This base board supports TMR HDLC I/O bus communication with Trident main processor module, with a transmission rate of 2Mbps, ensuring real-time transmission and reliable execution of control commands. At the same time, it is compatible with all functions of the TriStation 1131 programming environment, including online monitoring, fault diagnosis, and system configuration.

For applications that require mixing different types of outputs, the 2401L base board can be mixed with the standard 2401 base board in the same system. This flexibility allows users to choose the most suitable type of base board based on the specific needs of each output point, optimizing system design and cost-effectiveness.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer
  • UniOP ePAD32B/ePAD33B/ePAD33BT Industrial HMI
  • UniOP ePAD05/06 Human Computer Interface
  • UniOP ePAD03/04 Human Computer Interface
  • UniOP BKDR-46-0045 Human Machine Interface
  • UniOP BKDR-16 human-machine interface
  • Beckwith M-3425A Relay Guide
  • Basler DECS-200-2L excitation system
  • Basler DECS-250 Excitation System Debugging Guide
  • HA-800A Servo Drive Debugging Guide
  • JUMO dTRANS p35 Manual
  • KEBA XE020 RFID Module Manual
  • Honeywell SmartLine Transmitter Complete Guide
  • Eaton CROUSE-HINDS Series MA30 Lightning Protection Filter Installation Guide
  • BECKHOFF EL31xx Series 16 Bit EtherCAT Analog Input Terminal Manual
  • BECKHOFF AX5000 Servo Drive Maintenance Guide
  • BECKHOFF EL30xx Analog Input Diagnostic Guide
  • BECKHOFF EL70x7 Stepper Terminal Maintenance Guide
  • BECKHOFF CX52x0 Industrial Control Computer Maintenance Guide
  • BECKHOFF CX9000/CX9010 Hardware Maintenance Guide
  • BECKHOFF AM8xxx Motor Guide
  • BECKHOFF EL9xxx System Terminal Guide
  • Beckhoff EK110x/EK15xx Coupling Guide
  • BECKHOFF CX51x0 Embedded PC Deployment Guide
  • BECKHOFF CX2100-0014 Power Module Guide
  • BECKHOFF CX1000 Industrial Control PC Complete Manual
  • BECKHOFF CP69xx Panel Installation and Troubleshooting
  • Beckhoff C6030-0080 Industrial Control PC Guide
  • IFM O3D300 3D Sensor Debugging and Troubleshooting Guide
  • Allen Bradley Guardmaster 440R Safety Relay Troubleshooting and Configuration Guide
  • OMRON CS1 PLC System Maintenance and Troubleshooting Guide
  • GE Multilin EPM 9900P Power Quality Instrument Debugging and Fault Diagnosis Guide
  • Automotive LC-4 DC Brushless Motor Controller Debugging and Fault Diagnosis Guide
  • Doric NC500 Console Debugging and Troubleshooting Guide
  • Honeywell X-DCS2000/EN System Manager Debugging and Fault Diagnosis Guide
  • Kollmorgen SERVOSTAR 600 Servo Drive Field Troubleshooting and Maintenance Guide
  • ABB XFC Series Flow Computer Maintenance Guide
  • ABB ACS6000 Inverter IGCT Phase Module Replacement and Maintenance Guide
  • OMRON NX502 CPU Unit Hardware Installation and Maintenance Guide
  • OMRON NX102 Hardware Installation Guide
  • OMRON C200HX/HG/HE PLC Troubleshooting
  • Yamatake SDC35/36 Controller Application Guide
  • MITSUBISHI ELECTRIC GT25 Human Computer Interface Application Guide
  • Eurotherm Mini8 Controller Integration Guide
  • KEYENCE GC-1000 Safety Controller Manual
  • SICK RLY3-EMSS300 Safety Relay Manual
  • Troubleshooting of Siemens SIRIUS 3SK2 Safety Relay
  • Nordson DAGE4000 Bond Tensile Tester
  • HMS Anybus Communicator Gateway Replacement and Troubleshooting Guide
  • Allen Bradley 800T/H 30mm Button Troubleshooting and Replacement Guide
  • Schneider Modicon M340 Strict Environment Deployment and Troubleshooting Guide
  • Kepco BOP 1000M Troubleshooting Application
  • Siemens SIPROTEC 5 Replacement and Upgrade Guide
  • Banner XS/SC26 Security Controller Debugging and Troubleshooting
  • Allen Bradley MicroLogix 1500 Installation and Debugging
  • EOCR-PMZ (panel embedded) and EOCR-PFZ (embedded) motor comprehensive protector
  • Microchip PIC16F182X Low Power Design
  • FANUC α iS servo HRV calibration practice
  • Mitsubishi Electric GT23 Series HMI Maintenance Guide
  • Mitsubishi GT27 HMI Application Guide
  • Siemens SIMATIC ET 200M Selection
  • Lenze 8200 Vector Selection
  • Troubleshooting of Siemens MASTER DRIVES VC
  • FANUC I/O Unit A Maintenance Manual
  • Allen Bradley PLC-5 Classic Controller Complete Guide
  • Maintenance of M&C SP2006-H/DIL Sampling Probe
  • Pro face connection to Mitsubishi DIASYS Netmation
  • OMRON SYSMAC C-series/CVM1/CV series analog I/O units
  • LTI ServoOne Replacement and Troubleshooting
  • OMRON C-series AD/DA module configuration
  • Siemens 840C 611D Module Replacement Guide
  • Diagnosis and maintenance of ABB ACS550 frequency converter fault codes
  • OMRON NX1P2 Hardware Debugging Guide
  • Fuji FRENIC Mini inverter troubleshooting
  • Braided Forissier Braided Copper Strip Selection Guide
  • Mecc Alte MC200 Controller Engineering Debugging and Troubleshooting
  • Schneider Square D 9036/9037/9038 Electromechanical Liquid Level Controller
  • Pilz PSS 4000 distributed safety control
  • Schneider TeSys GV5/GV6 Motor Circuit Breaker Operation and Protection Guide
  • Eaton Freedom NEMA Contactor Starter Complete Guide
  • OMRON D4SL-N/D4SL-NSK10-LK Safety Door Switch Comprehensive Guide
  • NI CompactRIO Embedded System
  • Emerson Ovation I/O Module Troubleshooting and Replacement Practical Guide
  • MITSUBISHI A-series PLC Troubleshooting Replacement
  • Automation Direct DL06 D0-06DD1 Replacement Guide
  • IFM CR2530 Intelligent Controller Guide
  • OMRON FH/FHV series visual sensor controller
  • Pilz PDP67 F4 code troubleshooting
  • Panasonic FP-X PLC Replacement and Troubleshooting
  • OMRON CK3W-AX Multi axis Control Selection
  • Debugging and maintenance of EPSON RC90/RC90-B controller
  • Nthytronic Group iRTUe I/O Expansion Module
  • Schneider ATV320 Inverter Installation and Debugging Guide
  • Eaton SPB Drawdown Switch Maintenance Guide
  • GFS EVO-SP dual fuel retrofit complete solution
  • OMRON CJ2 CPU Troubleshooting and Maintenance
  • Complete Guide to Lenze ECS Servo System
  • GE EX2100e Excitation System Complete Guide
  • OMRON G3PW Power Controller: Parameter Setting and Troubleshooting Guide