Emerson 731 Series 48V600A/R48-3000E3 power supply

F: | Au:佚名 | DA:2024-01-30 | 810 Br: | 🔊 点击朗读正文 ❚❚ | Share:

The Net Sure731 system can be configured in four main ways:

1. Single AC input, no user AC output circuit breaker;

2. Single AC input, user AC output circuit breaker;

3. Dual AC input, manual switching;

4. Dual AC input, automatic switching (maximum configuration); In addition, in general, in the DC distribution unit of the power system, the load branch and the battery protection branch are connected by short-circuit bars, and the system does not have the load power-off function. If the system needs to provide the load power-off function, you need to select a load power-off unit instead of a short-circuit bar. The internal structure of the power system is based on the strongest configuration, and other configurations only remove certain components. In maximum configuration.

Net Sure731 48V600A intelligent high frequency switching power supply system is suitable for base stations, small and medium capacity exchanges, satellite communications, data communications and other power grid fluctuation range is very wide occasions. Net Sure731 48V600A Intelligent High Frequency Switching Power system is easy to operate, install and maintain. The AC input and output cables and DC input and output cables can enter and exit freely from the top or bottom of the cabinet.


Its main features are:

 rectifier module using active power factor compensation technology, power factor value of 0.99.

 The AC input voltage has a wide normal operating range. For the system without automatic switching, the AC input voltage can be 85~290V. For the system with automatic switching, the voltage range can be 125~285V.

 Rectifier module Ultra-low radiation. With advanced electromagnetic compatibility design, the rectifier module can meet the requirements of CE, NEBS, YD/T983 and other domestic and foreign standards. The conduction and radiation of the rectifier module can meet the requirements of Class B.  Rectifier module safety design in line with UL, CE, NEBS standards.

 The module has high power density.

 The rectifier module uses the non-damaging hot swap technology. The replacement time is less than 1 minute.

 The rectifier module has output overvoltage hardware protection and output overvoltage software protection. There are two options for software overvoltage protection: primary overvoltage locking mode and secondary overvoltage locking mode.

 Perfect battery management. It has the function of battery low voltage protection and load power-off (optional), which can realize temperature compensation, automatic voltage regulation, stepless current limiting, battery capacity calculation, online battery test and other functions.

 Up to 200 historical alarm records can be recorded. Up to 10 groups of battery test data can be recorded.

 Network design, provides RS232, Modem, dry contact and other communication interfaces, flexible networking, can realize remote monitoring, unattended.

 Perfect lightning protection design for AC and DC side.  Complete fault protection and fault alarm

 The power system cabinet can be installed against a wall and operated and maintained on the front of the cabinet.

 is equipped with an optional cabinet cover and air filter.

The working principle of the system is that the mains enters the rectifier module through the AC distribution branch, and the -48V DC rectified by each rectifier module enters the DC distribution through the tandem connection, and is provided to the communication equipment in multiple channels. Under normal circumstances, the system runs in parallel floating charging state, that is, the rectifier module, load, and battery work in parallel. The rectifier module not only supplies power to the communication equipment, but also provides floating charging flow for the battery. When the mains power is off, the rectifier module stops working, and the battery supplies power to the communication device to maintain the normal operation of the communication device. After the mains is restored, the rectifier module supplies power to the communication device and charges the battery to replenish the consumed power. The monitoring module uses centralized monitoring to manage AC power distribution and DC power distribution, and receives the operating information of the rectifier module through CAN communication and controls it accordingly. The monitoring module can also be connected to the local computer through RS232, and can be connected to the monitoring center through the Modem or other transmission resources (such as the official channel, etc.) to realize the centralized monitoring network of the power system.

The main function of the system

Net Sure731 48V600A Intelligent High frequency Switching Power Supply system has the following main functions:

 Excellent lightning protection design

 AC input overvoltage protection

 Load power-off and Battery Low Voltage protection (LLVD+BLVD)

 Fault alarm and protection

 Provides multi-channel and multi-specification DC output

 monitoring and four remote function

Ac input overvoltage protection

The Net Sure731 48V600A system has complete input overvoltage protection. For systems without automatic switching, the overvoltage protection is referred to the Overvoltage protection of the rectifier module in Chapter 2. For the automatic switching system with AC contactor, when the AC voltage reaches a certain set overvoltage point, the AC contactor will be automatically disconnected and the AC will be automatically cut off to protect the rectifier module and subsequent user AC equipment. When the AC input voltage returns to normal, the AC contactor can automatically close, and the rectifier module and other user AC equipment can automatically return to normal work.


Load power-off and battery low voltage protection

When the AC power is off and the rectifier module has no DC output, the battery starts to discharge. Set when voltage drops to undervoltage

When the fixed point is 45.0V (adjustable), the system will issue sound and light alarm. When the battery voltage continues to drop below the load

When the electric operating point is 44.0V (adjustable), the load power off contactor is disconnected and connected to the load power off branch

General communication loads (such as local switches) will be cut off from the power supply, and critical loads (such as transmission devices)

Standby) power supply can thus be extended. As the battery discharge process continues, if the battery discharge to termination

Voltage battery protection action point 43.2V (adjustable), the battery protection contactor will be disconnected, the battery discharge process will be terminated, and the power supply of all communication loads will be suspended, so as to avoid battery damage due to overdischarge. When an AC call comes in and the rectifier module outputs a normal DC voltage, the load is powered off and the battery contactor automatically closes, and the system returns to normal operation.

Functions such as load power-off and battery low voltage protection can be manually controlled.

Fault alarm and protection

Net Sure731 48V600A power supply system with complete fault warning and protection. The monitoring module can collect system data in real time, and detect the status of load output fuse, battery fuse, and II/C level surge protection device. You can flexibly set alarm levels for system faults, such as AC input overvoltage or undervoltage, DC output overvoltage or undervoltage, and module faults. You can also flexibly configure alarm types indicated by alarm dry nodes.


Choose Xiamen control Smith after sale worry

Excellent product quality

Only cooperate with manufacturers of first-line brands in the industry

Imports/Products

Good pre-sale service

Communicated with customers repeatedly about product model, quality, price and delivery date

Work with the customer to determine the best solution

Address user concerns in advance

Business execution in place

Ordered products delivered on time

Make perfect delivery plan to ensure the time limit

Assist users to handle the acceptance procedures

Perfect after-sales service

During the warranty period, problems will only be replaced and not repaired

Never put a problem on the back of your head

Service hotline 7x24 hours service


Solemn promise

1. All the items sold by the company, module card parts, etc., the quality problems arising from normal use during the warranty period are replaced free of charge, and there is no evasion.

2. For materials and equipment that have not been discontinued beyond the warranty period, only the cost of relevant parts will be charged for quality problems.

3. Provide replacement models and equipment replacement process services for discontinued materials and equipment.

4. Customers have purchased materials and equipment, lifetime free upgrade system software, related technical information provided free of charge.

5. Visit the use of materials purchased by customers from time to time, and solve any problems in time.

6. The company hotline provides 24-hour service, and the questions raised by customers are answered within 1 hour.

7. Not done, the company spirit of "thoughtful service, responsible to the end" attitude, from the customer's point of view to solve the problem, with serious and rigorous enterprise style, dedicated to each customer service.




  • Alcatel-Lucent KFA632 WMOTBUKLAA 10G Optical Interface Carrier
  • Alcatel-Lucent 9500-MPR ODU MPT-HC V2 3DB20474BAAB04 23GHz Microwave Radio
  • Alcatel-Lucent KFA720 WMOTCMVLAB SFP/XFP Optical Interface Carrier
  • Alcatel-Lucent 3AL00114AB Universal Interface Module
  • Alcatel-Lucent BBG9 S1:1 OHCTL Optical Hardware Control Module
  • Alcatel-Lucent FB16401-A-I03 GTD-5 Analog Master/Slave Control Board
  • Alcatel-Lucent MCR1721B Control Module
  • Alcatel-Lucent 9500-MPR 3DB20547ACAA01 ODU MPT-HC 11GHz Microwave Radio
  • Alcatel-Lucent 3HE01014AAAA02 Interface Module
  • Alcatel-Lucent 244-2091-005 High Density Digital Line Card V1.5
  • Alcatel-Lucent LAMBDAXTREME WWAA36 Optical Amplifier Module
  • Alcatel-Lucent 9500-MPR ODU MPT-HC 6GHz 2P-2 Radio 3DB20444BAAA05
  • Alcatel-Lucent 9500-MPR ODU MPT-HC V2 9558HC MPT-XP 6GHz 3DB20442BBAA02
  • Alcatel-Lucent 9500-MPR ODU MPT-HC 23GHz 3DB20476ABAA01 Microwave Radio
  • Alcatel Lucent 3HE01019AAAA01 Module
  • Alcatel CPU5 3BA23071 PCB Card with IO2 3BA23050 Set
  • Alcatel-Lucent 9500-MPR ODU MPT-HC V2 9558HC 6GHz 3DB20443BBAA02
  • Alcatel Lucent 500-1113-211 Rev H Channel Bank Assembly
  • Alcatel Lucent 89-0419-B-2 BA9ATS0FAB Frontal Compute Module
  • Alcatel-Lucent LambdaXtreme 1625 WWAF31 Optical Amplifier CP Module
  • Alcatel Z24 3BA53065 Analog Extension Card 3BA52065 AAAA KAZZB-01
  • Alcatel 3EH08263AAXX000448 OmniPCX Office Large PBX System
  • Alcatel Lucent VSEM-C 3FE62453 XA VAUCAJZKAA 7330 DSLAM Line Card
  • Alcatel-Lucent 9500-MPR ODU MPT-HC 3DB20432BAAA04 18GHz Microwave Radio
  • Alcatel-Lucent 9500-MPR ODU MPT-HC 3DB20546ACAA01 11GHz Microwave Radio
  • Alcatel-Lucent 3DB04823AAAA Circuit Board
  • Alcatel-Lucent 3DB04530AAAA Circuit Board
  • Westell MDIU Modular DAS Interface Unit CS21-005-105Q
  • Alcatel-Lucent 90-0423-01 Control Card
  • Alcatel-Lucent 3AL91792AA 01 iL-1.2 Optical Interface LC Connector
  • Alcatel-Lucent 109637454 WA82 SP2B MODL908832 – Interface Module
  • Alcatel-Lucent MDEE DPB11 Part 109773580 – Digital Processing Board
  • Alcatel 3EH76027ADAD OmniPCX Enterprise Communication Server R500/30.4
  • Alcatel-Lucent 3EH73084AEJD Gateway Driver Board GD-3 – Communication Interface
  • Alcatel-Lucent 9500-MPR ODU Radio MPT-HC V2 3DB20476BAAB04 23 GHz Microwave Outdoor Unit
  • Alcatel-Lucent 9396 Digital 2U NodeB Indoor – UMTS Base Station
  • Alcatel-Lucent 3HE03607AA CFM-XP Control Fabric Module – Switch Fabric Controller
  • Alcatel-Lucent 8232 DECT Mobile Handset – Cordless Enterprise Phone
  • Alcatel-Lucent 244-2082-201 Sierra NAC V3.1 Slave Package – Network Access Control
  • Alcatel-Lucent 408154912 CPU Rear I/O Pack Card – Backplane Interface Module
  • Alcatel-Lucent 3AL82037ADAA SFP Module
  • Alcatel-Lucent OMQ 408645968 Optical Module
  • Alcatel-Lucent 9500 MPR 8-Slot Shelf 3DB18485AB
  • Alcatel-Lucent 408154904 CPU I/O Card
  • Alcatel-Annecy 5150 CP Turbo Vacuum Pump
  • Alcatel-Lucent 3EH73084AEJD08 Card
  • Alcatel-Lucent 3EH73050ABAB Interface Card
  • Alcatel-Lucent 3HE06151ABAA01 SFP Line Card
  • Alcatel-Lucent 8DG59242AD Power Filter
  • Alcatel-Lucent IMM48-1GB-TX 48-Port Module
  • Alcatel Lucent 3CM03285MQ02 Module
  • Alcatel 3HE07158BA 7750 SR-12 IMM-2PCA-FP3 Optical Transceiver
  • Alcatel-Lucent 9396 Digital 2U NodeB Outdoor with Indoor Mainframe and Alarm Module
  • Alcatel Lucent MPX-16/64-T-L3 MPX1664TL3 Multiplexer Module
  • Alcatel Lucent 3EH73052AB Power Supply Module
  • Alcatel Lucent ASM2-155FM-2W-4C ASM2155FM2W4C Switch Fabric Module
  • Alcatel Lucent 3AL00124ABAB Interface Card
  • Alcatel-Lucent 1AB429380001 Cable Assembly
  • Alcatel Z24 3BA53065 Analog Extension Card 3BA53065AA
  • Alcatel-Lucent 9500-MPR 11GHz MPT-HC ODU Microwave Packet Radio 3DB20371ACAA01
  • Alcatel-Lucent RRH1900-4x45 Remote Radio Head
  • Alcatel-Lucent 3HE00028AA Ethernet Line Card
  • Alcatel-Lucent 3HE04939CE CWDM SFP Transceiver
  • Nokia Alcatel-Lucent 3FE66546AA Fan Module
  • Alcatel-Lucent SSP-6 Speech Signal Processor Board
  • Alcatel-Lucent 500-1113-212 Channel Bank Assembly
  • Alcatel-Lucent EZ32-2 Board 3BA23265ADKE 01
  • Alcatel-Lucent GSM-FM-2W-4C Filter Module
  • Alcatel-Lucent 3AL00378AF Interface Card
  • Alcatel-Lucent 3AL00124ABAC Interface Module
  • Alcatel-Lucent BJB1 PWPQALGAAG 48V Independent Microprocessor Board
  • Alcatel Lucent MDR-8000 Microwave Digital Radio MDR-8506-4 with 13 Modules
  • Alcatel Lucent 3AL00424AA Interface Card
  • Alcatel Lucent 3BA73012AB Power Supply Module
  • Alcatel Lucent ESX-100C-32W ESX100C32W Power Supply Module
  • Alcatel Lucent GSX-K-FM-2W GSXKFM2W Fan Module
  • Alcatel 8DG59247AA Optical Protection Switch Card
  • Alcatel Lucent 91-E03100-B 91E03100B Interface Module
  • Alcatel Lucent FSX-FM-1W FSXFM1W Fan Module
  • Alcatel Lucent RRH2X40-07L-AT Remote Radio Head
  • Alcatel-Lucent 9500-MPR MSS-8 Shelf 3DB18485CA
  • Alcatel Annecy ACP20 Vacuum Pump CP20
  • Alcatel-Lucent 9500 MPR P32E1DS1 E1 PDH Card
  • Alcatel-Lucent J98726AL-2 D4OI210DAA Module
  • Alcatel 409113651 RRH700L1 700MHz Remote Radio Head
  • Alcatel io2 3ba23050 PCB Card
  • Alcatel-Lucent MDR-8000 MDR-8706-8 Digital Radio
  • Alcatel-Lucent ACT2300M Turbo Pump Controller AF042134A
  • Alcatel-Lucent OmniPCX Office Medium PowerCPU PRA-TI
  • Alcatel-Lucent 9500 MPR 23GHz ODU 3DB23045HDAA01
  • Alcatel-Lucent 9500 MPR ODU Outdoor Unit 300 11GHz TX Low HP 3DB23035AAAA01
  • Alcatel-Lucent ECNT-C 3FE25676 BA AK 06 Termination Card
  • Alcatel Lucent MDR-8000 Microwave Digital Radio MDR-8606-45 with 13 Modules
  • Alcatel-Lucent 849144415 KS-24829L1 Remote Radio Head v1.4
  • Alcatel CFF 450 Turbo Pump Controller 137171
  • Alcatel-Lucent ACS108 109579896 004 Access Controller
  • Alcatel-Lucent OS6850-48 Network Switch with PS-126W-AC Power Supply
  • Alcatel Lucent DFP-CM-14B/2T Filter DCMA Base Station
  • Alcatel Lucent ESX-K100C32W4 ESXK100C32W4 Power Supply Module
  • Alcatel Lucent 91-E03100-A 91E03100A Interface Module
  • Alcatel-Lucent STGR-LIM-A2P-72-HBI ADSL2+ High Bandwidth Module
  • Alcatel-Lucent 9500 Microwave Packet Radio MPT-3DB20547BBAA02
  • Alcatel Lucent Enterprise 4049-4059 MMK Keyboard Console Kit
  • Alcatel-Lucent RRH4X40-1900 Remote Radio Head
  • Alcatel Lucent OS6450-P48 Switch
  • Alcatel Lucent 625617-000-001 Cable Assembly
  • Alcatel Lucent 108320 Module
  • Alcatel Lucent TN801B Board
  • Alcatel-Lucent RRH2X50-800 LTE Remote Radio Head
  • Alcatel Lucent CPU8 Board 3BA23258AB OmniPCX 4400
  • Alcatel-Lucent 3EM22617AAAE 9500 MPT-HL Microwave Radio Transceiver
  • Alcatel-Lucent CPU7-2 3BA23259AAAD 7750 SR Control Processor Module
  • Alcatel-Lucent 9500 Microwave Packet Radio MPT-3DB20371BCAA01
  • Alcatel-Lucent Enterprise 4059 MMK Keyboard + Phone PAC Kit
  • Alcatel-Lucent Nokia 3HE10329AA 7750 SR Series Router Module
  • Alcatel-Lucent 7705 SAR-W IP MPLS Service Aggregation Router 3HE07349AA
  • Alcatel-Lucent-Nokia 3HE08429AARC01 7750 SR SFM5-7 Switching Module
  • Alcatel-Lucent 3HE00272DB 7750 SR-7 DC Chassis with PEM3+EFT
  • Alcatel-Lucent ACT 1300M/1600M HT Turbo Pump Controller
  • Alcatel Lucent IMM48-1GB-TX 3HE03625AAG01 48-Port 7750 SR-12 Interface Module
  • Alcatel-Lucent AP-500 Wireless Access Point
  • Alcatel-Lucent ATP-150 Power Supply
  • Alcatel-Lucent 622-8603-012 Optical Transceiver
  • Alcatel-Lucent 270-0038-010 10.5 VDC Power Supply
  • Nokia 9500-MPR Microwave Radio Module XPIC-RPS/3DB20116BCAA01
  • Alcatel-Lucent 3DB19017AB EAS Access Switch v2
  • Alcatel-Lucent 3AL81072AA Matrix Enhanced Unit - Cross-Connect Module
  • Alcatel-Lucent MDR-8606-135 6GHz Digital Microwave Radio