ABB CONTROL UNIT SYN 5201A-Z,V277 3BHB006714R0277

F: | Au:FAN | DA:2025-07-14 | 554 Br: | 🔊 点击朗读正文 ❚❚ | Share:

ABB CONTROL UNIT SYN 5201A-Z,V277 3BHB006714R0277

Product Overview

ABB Control UNIT SYN 5201A-Z, V277 3BHB006714R0277 is a control unit launched by ABB for synchronous and parallel operations, belonging to the ABB SYNC HROTACT series products. This product features a dual channel configuration, with one channel monitoring the operation of the other, greatly improving operational safety. It can be used to ensure precise timing and control in complex industrial systems and plays an important role in the field of industrial automation.


Product Usage

Mainly used to ensure precise timing and control in complex industrial systems, it is a key component in industries such as power generation, telecommunications, and industrial automation, where precise synchronization is crucial.

Performance characteristics

Rich communication interfaces: Supports logically independent dual Profibus DP buses, can set dip switches to specific communication rates or adaptively, can flexibly choose 1-2 Profibus DP electrical interfaces and 1-2 155 Mbps fiber optic interfaces, supports redundant dual network and fiber ring network topologies.

Long communication distance: Fiber optic communication distance exceeds 20 kilometers, with a 155 Mbps high-speed optical interface, which can better support long-distance reliable transmission of burst data.

Clear status indication: equipped with 5 dual color LED status indicator lights, with fiber optic link and power failure relay output alarm function.

Good protection performance: The electrical interface has 4000V lightning protection, 1.5A overcurrent, and 600W surge protection, meeting industrial design standards and passing EMC testing certification. Adopting DC (12-36V) wide redundant dual power supply, with reverse protection function, protection level of IP30, and shell reinforced with corrugated aluminum material.

Easy installation: Using standard industrial 35mm guide rail installation method, it is convenient to install in the control cabinet.

3BHB006714R0271 | ABB

Technical parameters

Safety level: PL e, SIL 3- SIL CL 3- PL e - Cat. 4.

Input/output: There are 8 digital inputs, 2 OSSD PNP outputs (400 mA at 24 VDC) with short circuit, overload, and reverse polarity protection, 2 PNP status outputs (100 mA), and 4 test outputs.

Working temperature: -10 ℃ to 55 ℃, storage temperature: -20 ℃ to 85 ℃.

Power supply: 24V DC ± 20%.

Dimensions: Approximately 108mm × 22.5mm × 114.5mm, gross weight of approximately 206.8g.


Key advantages

High security: With a dual channel design, one channel monitors the operation of the other channel, greatly improving the safety during the operation process and reducing the risk of system abnormalities caused by equipment failures.

Wide applicability: It not only supports 50/60Hz standard power grid, but also supports 16 2/3Hz frequency, suitable for various types of power generation equipment and complex power grid environments, whether it is conventional power plants or some special industrial self owned power plants.

Accurate synchronization performance: With advanced digital technology and precise algorithms, high-precision frequency and voltage matching and synchronization operations can be achieved, effectively improving the stability and reliability of power grid operation, reducing power fluctuations and equipment losses caused by poor synchronization.

Powerful communication capability: supports multiple communication protocols, facilitates integration with various devices, achieves intelligent management and remote control of the system, and can meet the needs of different users for centralized monitoring and management of the system.

High reliability: Complies with industrial design standards and has passed EMC testing certification. The electrical interface has 4000V lightning protection, 1.5A overcurrent, 600W surge protection, and adopts DC (12-36V) wide redundant dual power supply with reverse protection function. The protection level is IP30, and the shell is reinforced with corrugated aluminum material, which can operate stably in harsh industrial environments.


Precautions

During the installation process, it is necessary to strictly follow the instructions in the product manual to ensure the correct installation position and avoid equipment damage or performance degradation caused by improper installation. Special attention should be paid to the firmness and correctness of electrical connections to prevent problems such as short circuits or open circuits.

Before use, carefully inspect the appearance of the equipment for any damage and ensure that all components are complete. At the same time, it is necessary to confirm whether the parameters of the input power supply are consistent with the equipment requirements, in order to avoid irreversible damage to the equipment caused by power problems.

During operation, regular inspections of the equipment should be carried out to observe whether the operating status indicator lights are normal and whether there are any abnormal noises or heating phenomena. If any abnormalities are found, the machine should be stopped immediately for troubleshooting. Do not forcefully restart the equipment until the fault is resolved.

When setting and maintaining equipment parameters, it must be operated by professional personnel and carried out in the event of a power outage to prevent safety accidents or equipment failures caused by misoperation. At the same time, after the operation is completed, carefully check the parameter settings to ensure that they are correct and error free.

The device should be stored in a dry, ventilated, and non corrosive gas environment, avoiding direct sunlight and strong electromagnetic interference. If the device is not used for a long time, it is recommended to conduct regular power on checks to ensure that the device is functioning properly.


Similar model supplement

SYN5200A-Z: also belongs to the ABB SYNC HROTACT series products, similar to SYN 5201A-Z, designed for industrial automation synchronous control. The working voltage is 24V DC, and the communication protocol supports Ethernet/IP, Profibus, and Modbus. The difference lies in that its performance parameters such as processor speed may differ from SYN 5201A-Z, and there may also be differences in input and output capacity. For example, SYN5200A-Z may support a different number of I/O points in certain application scenarios, and users can choose according to their specific system requirements and budget.

ABB SYN5201a-Z, V217: This is also an automatic synchronization device, belonging to the SyncHROTACT 5 series product line. Compared with SYN 5201A-Z, V277, the input voltage range (measured input U1, U2) is 50 to 130 VAC (rated), and the auxiliary power supply (AC/DC) is 24-250 V DC, 100-230 V AC. There are differences in some detailed parameters, and there may also be differences in applicable conditions such as working environment temperature. For example, its working environment temperature is+5 to+70 ° C, and users need to choose it reasonably according to their actual usage environment and working conditions.

ABB SYNCHROTACT 5 SYN 5201a-Z,V2277 3BHB006714R2277 Reasonable price ...

  • Basler KR7FFX Static Regulator 840V
  • Basler EL200-7 Voltage Regulator 90-660VAC 7A
  • Basler PRP210-1 Reverse Power Relay 9056300102
  • Basler SSR 63-12 Static Regulator 600VAC
  • Basler 9289901106 Digital Board
  • Basler DECS100 Voltage Regulator DECS100A01
  • Basler Electric CEM-2020 Contact Expansion Module
  • Basler Electric BE3-25-1 C1 N4 Synchronizing Check Relay
  • Basler Electric ACA2000-50GM GigE Camera 2MP 50fps
  • Basler Electric ACA2240-20GMSYM GigE Camera Sony IMX264
  • Basler BE1-50G Ground Overcurrent Relay
  • Basler PRS250 Veri-Sync Relay
  • Basler MOC2199 Output Module
  • Basler UFOV 260A Underfrequency Overvoltage Module
  • Basler BE-15482-001 Control Module
  • Basler LSP4-7 Protective Relay
  • Basler SCP 250-G-60 VAR Power Factor Controller
  • Basler BE146N Negative Sequence Overcurrent Relay
  • Basler APR63-5 Automatic Voltage Regulator
  • Basler 9507900107 SR8A Retrofit Voltage Regulator
  • Basler BE1-320 Directional Power Relay
  • Basler KR7F Voltage Regulator 9116200100
  • Basler UFOV 260A Overvoltage Protective Module
  • Basler AEC63-7 Analog Excitation Controller
  • Basler 9992D90G01 Control Module
  • Basler 6966D22G01 Control Board
  • Basler 6965D40G01 Control Board
  • Basler BE1-50/51M-104 Overcurrent Relay
  • Basler BE1-BPR Programmable Breaker Relay
  • BASLER Electric SSR 125-9 1256 00 102 Static Voltage Regulator
  • Basler Electric MVC 112 Manual Voltage Control
  • Basler Electric 9321000102 Control Module
  • Basler Electric RA-70-MDCT7 Rectifier Assembly
  • Basler Electric ACA1300-60GM GigE Camera
  • Basler Electric 6427C85G01 Interface Board
  • Basler Electric 6965D05G01 Control Board
  • Basler Electric ACA2500-14UC Current Transducer
  • Basler Electric 9170206111 Protective Relay
  • Basler Electric BE1-11-G6D1M1J1P0E000 Protection Relay
  • Basler Electric BE1-50/51B-107 Overcurrent Relay
  • Basler 9121000106 Voltage Controller
  • Basler B3E-E1P-A0N0F Solid State Protective Relay
  • Basler 9121000106 Manual Voltage Control
  • Basler PRP320 Motor Pull-out Relay
  • Basler SSE-N 250-9KW Shunt Exciter Regulator
  • Basler BE1-50-51B-107 Overcurrent Relay
  • BASLER ELECTRIC MVC 108 MANUAL VOLTAGE CONTROL MODULE 9 0370 00 102
  • Basler BE1-59N-A7E-D1J-D0N0F Ground Overvoltage Relay
  • Basler BE1-46N-G1E-B8P-B0N0F Negative Sequence Overcurrent Relay
  • Basler BE1-951 Overcurrent Protection System
  • Basler Electric MOC2199 Motor Operated Potentiometer
  • Basler Electric BE1-60 Voltage Balance Solid State Relay B1FA1C1M1F
  • Basler Electric BE1-67N Directional Overcurrent Relay
  • Basler Electric PIA2400-17GM Interface Module
  • Basler Electric V6RAB Rectifier Module
  • Basler Electric BE1-32R Reverse Power Relay B2E E1R A0N1F
  • Basler Electric IFM-150 Firing Circuit Chassis 120V AC
  • Basler Electric IFM-102 Firing Circuit Chassis 120V AC
  • Basler Electric 9170206111 NSNP Control Module
  • Basler Electric SSR 63-12 Static Voltage Regulator
  • Basler UFOV 260A Overvoltage Protective Module
  • Basler SCA1300-32GM CCD Camera Lens Enclosure
  • Basler BA1-27 Under Voltage Relay
  • Basler 149D866G06 Control Board
  • Basler 9072300130 Power Supply Module
  • Basler CBS 305 Current Boost System
  • Basler BE1-60 Voltage Balance Relay
  • Basler Electric CBS 212 Current Boost System Sensing 120/240VAC 50/60Hz 10VA
  • Basler MVC-300 Manual Voltage Control Unit
  • Basler SSR125-12 Static Voltage Regulator 918500102
  • Basler SR32A2B05B3E Static Voltage Regulator
  • Basler Electric BE1-59N Ground Fault Overvoltage Relay
  • Basler Electric 9110000113 Excitation Module
  • Basler Electric 90-72300-114 Control Accessory
  • Basler Electric PRS-250 Protection Relay System
  • Basler Electric BE1-50/51M-109 Overcurrent Relay
  • Basler Electric SR4A1B10B3E Static Voltage Regulator
  • Basler Electric CBS 212 Current Boost System
  • Basler Electric SR32A2B05B3E Static Voltage Regulator
  • Basler Electric MOC2207 Motor Operated Potentiometer
  • Basler Electric SR4A1B05A3E Static Voltage Regulator
  • Basler Electric BE1-32R Power Relay B2EE1PA0N1F
  • Basler BEI-81 Underfrequency Relay
  • Basler CBS 212A Current Boost System
  • Basler SSR 63-12 Static Voltage Regulator
  • Basler DGC-2020 Digital Genset Controller
  • Basler BE1-32 Reverse Power Relay
  • Basler BE1-50/51B-207 Overcurrent Relay
  • Basler BE1-951 Overcurrent Protection System
  • Basler 9073800-103 Power Supply
  • Basler SCA1300-32FC CCD Camera
  • Basler 9073800-103 Power Supply
  • Basler SCA1300-32FC CCD Camera
  • Basler L304KC Protective Relay
  • Basler BE3-25-1S1N4 Time Overcurrent Relay
  • Basler 9032300113 Excitation Support System
  • Basler BE1-59N Ground Overvoltage Relay
  • Basler MVC-300 Manual Voltage Control Unit
  • Basler MOC2102 Potentiometer
  • Basler BE1-87G Generator Differential Relay
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric DECS 125-15-B2C5 Digital Excitation System
  • Basler Electric PLA2400-12GM Power Supply
  • Basler Electric BE1-50/51B-235 Overcurrent Relay
  • Basler Electric BE1-27/59 Undervoltage Overvoltage Relay
  • Basler Electric CEM-2020 Contact Expansion Module
  • Basler Electric BE1-32R Solid State Power Relay
  • Basler Electric BE1-700 Digital Generator Management Relay
  • Basler Electric BE1-59N Ground Fault Overvoltage Relay
  • Basler Electric BE10493002 Protection Module
  • Basler Electric BEI-79A1AA5CA3M1F Digital Annunciator
  • Basler Electric SSR 32-12 Static Voltage Regulator
  • Basler Electric BE1-CDS240 Current Differential System
  • Basler Electric BE1-67 Directional Overcurrent Relay
  • Basler Electric 9121000106 DECS-100 Voltage Controller
  • Basler Electric BEI-871 Interface Module
  • Basler Electric 8650C72 Exciter Control Module
  • Basler Electric RDP-110-S1 Generator Annunciator
  • Basler Electric BE1-32O/U Directional Power Relay
  • Basler Electric BE2000E AVR Voltage Regulator
  • BASLER ELECTRIC BE1-50F2EA1PA0N0F Instantaneous Overcurrent Relay
  • BASLER ELECTRIC BE1-81T1EE1WA0N1F Underfrequency Relay
  • Basler BE1-67 Directional Overcurrent Relay
  • Basler BE1-25/79TR Reclosing Relay
  • Basler CEM-2020 Contact Expansion Module
  • Basler BE1-11 Overcurrent Protection Relay
  • Basler BE1-GPS Generator Protective Relay
  • BASLER ELECTRIC MVC-300 MANUAL VOLTAGE CONTROL UNIT 9121000106