ABB AI625 Analog Input 16ch, 12 Bit, 4-20 mA

F: | Au:FAN | DA:2025-04-27 | 778 Br: | 🔊 点击朗读正文 ❚❚ | Share:

ABB AI625 Analog Input 16ch, 12 Bit, 4-20 mA

Product Positioning

ABB AI625 Analog Input 16ch, 12 Bit, 4-20 mA is a 16-channel analog input module specially designed for industrial automation data acquisition, focusing on converting 4 - 20mA standard analog current signals into digital signals to provide accurate data support for PLC, DCS and other control systems, widely used in electric power, chemical industry, manufacturing industry and other industrial scenarios that require real-time monitoring of analog data. Widely used in electric power, chemical industry, manufacturing industry and other industrial scenarios that require real-time monitoring of analogue data, is an important component to achieve accurate control and efficient management of industrial automation.


Core Technical Parameters

Channel and Signal Parameters

Number of channels: 16 independent analog input channels, can simultaneously collect 16 4-20mA analog current signals to meet the demand for simultaneous monitoring of multiple parameters, suitable for multi-node data collection in complex industrial systems.

Signal type: only support 4 - 20mA current signal input, the signal has the advantages of strong anti-interference ability, long transmission distance, etc., commonly used in industrial field sensor signal transmission, such as pressure sensors, flow sensors and other equipment signal acquisition.

Resolution: 12-bit resolution, the input signal can be converted to 4096 (2^12) discrete digital values, the measurement accuracy can reach ± 0.1% of the full scale, to ensure the accuracy of data acquisition, can effectively capture the signal changes.


Performance Parameters

Sampling rate: each channel sampling rate of 500Hz, can quickly respond to signal changes, for dynamic changes in the analogue (such as real-time flow fluctuations in the pipeline) can be collected in a timely manner to provide real-time data for the control system support.

Input Impedance: The input impedance is less than 250Ω, which meets the standard requirement of 4-20mA current loop, ensuring the stability of current during signal transmission and reducing signal attenuation and interference.

Isolation characteristics: electrical isolation design between channels and between channels and systems, isolation voltage up to 500V AC, effectively preventing signal crosstalk and the spread of electrical faults, improve system stability and safety, especially for industrial sites with complex electromagnetic environments.


Communication and interface parameters

Communication protocol: support Modbus RTU, Profibus DP and other mainstream industrial communication protocols, which is convenient to integrate with different brands of controllers (e.g. ABB, Siemens, Schneider and other PLCs) and the host computer system, and realise rapid data transmission and interaction.

Communication interface: Equipped with RS485 interface (for Modbus RTU communication), DP interface (for Profibus DP communication), the interface adopts industrial-grade design, has good anti-interference ability, supports long-distance communication, and ensures stable data transmission.

Wiring: detachable terminal block wiring, each channel corresponds to an independent terminal, clear identification, easy to install, debug and maintain, support hot-swappable operation, can be replaced when the system is running the module, reduce downtime.


Mechanical and environmental parameters

Size and installation: compact design, width of only 25mm (standard rail mounting specifications), saving space in the control cabinet. Support 35mm DIN rail mounting, easy installation process, can be installed side by side with other modules to achieve flexible system expansion.

Protection grade: IP20, suitable for installation in indoor control cabinets and other places with good protection environment, can prevent solid foreign objects with a diameter of more than 12mm from entering, and avoid the accumulation of dust affecting the performance of the module.

Working environment: working temperature range - 40℃ - 70℃, storage temperature - 40℃ - 85℃, can adapt to harsh industrial environments; relative humidity 5% - 95% (non-condensing), with moisture-proof ability, high temperature, low temperature, humidity and other environments can still be stable operation.


Technical Advantages

High-precision data acquisition

Accurate signal conversion: With 12-bit high resolution and advanced A/D conversion technology, it can accurately convert 4-20mA analogue signals into digital signals, and with the auto-calibration function, it can periodically correct the measurement error to ensure stable long-term operation accuracy and provide a reliable data base for industrial control.

Low-noise design: Built-in digital filtering algorithm can effectively suppress high-frequency noise and interference in the signal, and different filter strengths, such as mean filter, median filter, etc., can be selected through the software configuration, so as to make the collected data smooth and stable, which is suitable for application scenarios with high requirements on signal quality.

Highly reliable operation

Redundancy and Failure Diagnosis: Some models support redundancy configuration, automatic switching of standby modules when the main module fails to ensure uninterrupted operation of the system; built-in self-diagnostic function, real-time monitoring of power supply, communication, channel status, faults through the indicator and communication protocols to provide rapid feedback, to facilitate rapid positioning and repair.

Anti-interference ability: adopting multi-layer circuit board layout and shielding technology, combined with isolation design, it can effectively resist the influence of electromagnetic interference and power grid fluctuation at industrial sites, and can still work stably in high electromagnetic environments such as metallurgy, chemical industry, etc., reducing the system failure rate.

Flexible and easy-to-use features

Convenient configuration management: Supporting special configuration software, the graphical interface can quickly set the channel parameters (such as range, filtering mode, alarm threshold), support batch configuration, improve debugging efficiency; support online modification of parameters, without interrupting the system operation.

Strong system compatibility: standardised communication protocols and interface design, can be seamlessly integrated into various industrial automation systems, whether it is a new project or an upgrade of the existing system, can be quickly accessed to reduce the cost and difficulty of system integration.


Application Fields

Power industry

Substation monitoring: It is used to collect analogue data such as current, voltage and power of power equipment, and transmit them to the monitoring system through 4-20mA signals to monitor the operation status of the substation in real time, and discover abnormal situations such as overload and short circuit in time to ensure the safe and stable operation of the power system.

Power plant control: In thermal and hydroelectric power plants, it collects parameters such as boiler pressure, steam flow, generator current, etc., and provides data for the DCS system, so as to achieve precise control of power generation process and optimise the efficiency of energy utilisation.

Chemical industry

Production process monitoring: connecting pressure sensors, temperature sensors, liquid level sensors and other equipment, collecting data such as reactor pressure, temperature, pipeline flow, real-time monitoring of the chemical production process to ensure stable reaction conditions and prevent safety accidents caused by abnormal parameters.

Environmental protection monitoring: It is used to monitor the key indicators of wastewater and waste gas treatment in chemical enterprises, such as the pH value of wastewater, COD content, and the concentration of waste gas pollutants, etc., to provide data support for environmental protection supervision and to ensure that the enterprise meets the emission standards.

Manufacturing

Automated production line: In automotive manufacturing, electronic assembly and other production lines, collect analogue quantities such as robot arm torque, conveyor belt tension, equipment temperature, etc., to achieve real-time monitoring of production line operation status and fault warning, and improve production efficiency and product quality.

Quality inspection: connecting inspection equipment, collecting analogue signals such as product size, weight, surface roughness, etc., judging product quality through data analysis, realizing automated quality inspection, reducing manual inspection errors and costs.


Precautions

Installation and wiring

Environmental requirements: should be installed in a dry, ventilated, non-corrosive gas control cabinet, away from strong electromagnetic interference sources and heat sources, to ensure that the normal operation of the module environmental temperature and humidity meet the requirements.

Wiring specification: Use shielded twisted pair cable to connect 4-20mA signal source, and ground the shield reliably; follow the identification of the terminal row to connect correctly, and distinguish between positive and negative poles of the power supply and the signal input channel; avoid parallel laying with power cables to prevent electromagnetic interference.

Use and maintenance

Parameter setting: Before using configuration software to set parameters, confirm that the signal source range is consistent with the module settings; regularly check the alarm threshold settings to ensure timely response to abnormal conditions.

Daily maintenance: Clean the dust on the surface of the module regularly; check the status of the indicator to determine whether the operation is normal; according to the frequency of use and environmental conditions, calibrate the module every 1 - 2 years to ensure the accuracy of measurement.

Comparison and supplement of other models

Performance upgrade models

ABB AI635: the same 16-channel design, but the resolution has been increased to 16 bits, with a measurement accuracy of ±0.05% F.S., and the sampling rate has been increased to 1000Hz, which is suitable for scientific research, precision processing and other fields that have very high requirements for accuracy and real-time performance.

ABB AI645: the number of channels is extended to 32 to meet the needs of large-scale data acquisition, support for more sensors to access, suitable for large-scale factory automation monitoring system.

Function expansion models

ABB AI625 - HART: AI625 based on the addition of HART communication protocol support, can communicate with HART intelligent instrumentation, instrument parameters to achieve remote configuration and diagnostics, suitable for oil, gas and other industries that require in-depth instrumentation management.

ABB AI625 - Isolated: Enhanced isolation performance, isolation voltage upgraded to 1000V AC, further improve the system anti-interference ability, suitable for complex electromagnetic environment, high security requirements of special industrial scenarios.

产品图片

  • Basler BE1-57/27R Solid State Protective Relay
  • Basler BE3-25AX Time Overcurrent Relay
  • BASLER ELECTRIC BE1-24/A1EF1JC1N0F / BE124A1EF1JC1N0F Overvoltage Relay
  • Basler Electric Solid State Protective Relay BE1-32R Style B2ED1PB0N0F
  • Basler BE3-51-3E1E1 9320000110 24VDC Overcurrent Relay
  • Basler UFOV 260A Underfrequency Overvoltage Module
  • Basler 50F4EA1PA0N0F Instantaneous Overcurrent Relay
  • Basler BE1-50 Instantaneous Overcurrent Relay
  • Basler BE1-32 Solid State Protective Relay
  • Basler SCP 250-G-60 VAR Power Factor Controller
  • Basler BE1-59N A5EE1KC0N0F Ground Fault Relay
  • Basler BE1-79A Reclosing Relay
  • Basler BE1-32R E1EA1OA0N0F Reverse Power Relay
  • Basler DCQA-103 DCQC104-1 CMX-7D Circuit Board
  • Basler SSR125-12 Static Regulator 918500102
  • Basler 90 17709 112 Regulator Control Board
  • Basler AVC63-4 AVC634 Voltage Regulator
  • Basler 9 1049 04 100 PC Board Control Module
  • Basler SR4A-2B03B3A Static Voltage Regulator
  • Basler SR8A-2B15B3A Static Voltage Regulator
  • Basler KR7FFX Static Regulator 840V
  • Basler EL200-7 Voltage Regulator 90-660VAC 7A
  • Basler PRP210-1 Reverse Power Relay 9056300102
  • Basler SSR 63-12 Static Regulator 600VAC
  • Basler 9289901106 Digital Board
  • Basler DECS100 Voltage Regulator DECS100A01
  • Basler Electric CEM-2020 Contact Expansion Module
  • Basler Electric BE3-25-1 C1 N4 Synchronizing Check Relay
  • Basler Electric ACA2000-50GM GigE Camera 2MP 50fps
  • Basler Electric ACA2240-20GMSYM GigE Camera Sony IMX264
  • Basler BE1-50G Ground Overcurrent Relay
  • Basler PRS250 Veri-Sync Relay
  • Basler MOC2199 Output Module
  • Basler UFOV 260A Underfrequency Overvoltage Module
  • Basler BE-15482-001 Control Module
  • Basler LSP4-7 Protective Relay
  • Basler SCP 250-G-60 VAR Power Factor Controller
  • Basler BE146N Negative Sequence Overcurrent Relay
  • Basler APR63-5 Automatic Voltage Regulator
  • Basler 9507900107 SR8A Retrofit Voltage Regulator
  • Basler BE1-320 Directional Power Relay
  • Basler KR7F Voltage Regulator 9116200100
  • Basler UFOV 260A Overvoltage Protective Module
  • Basler AEC63-7 Analog Excitation Controller
  • Basler 9992D90G01 Control Module
  • Basler 6966D22G01 Control Board
  • Basler 6965D40G01 Control Board
  • Basler BE1-50/51M-104 Overcurrent Relay
  • Basler BE1-BPR Programmable Breaker Relay
  • BASLER Electric SSR 125-9 1256 00 102 Static Voltage Regulator
  • Basler Electric MVC 112 Manual Voltage Control
  • Basler Electric 9321000102 Control Module
  • Basler Electric RA-70-MDCT7 Rectifier Assembly
  • Basler Electric ACA1300-60GM GigE Camera
  • Basler Electric 6427C85G01 Interface Board
  • Basler Electric 6965D05G01 Control Board
  • Basler Electric ACA2500-14UC Current Transducer
  • Basler Electric 9170206111 Protective Relay
  • Basler Electric BE1-11-G6D1M1J1P0E000 Protection Relay
  • Basler Electric BE1-50/51B-107 Overcurrent Relay
  • Basler 9121000106 Voltage Controller
  • Basler B3E-E1P-A0N0F Solid State Protective Relay
  • Basler 9121000106 Manual Voltage Control
  • Basler PRP320 Motor Pull-out Relay
  • Basler SSE-N 250-9KW Shunt Exciter Regulator
  • Basler BE1-50-51B-107 Overcurrent Relay
  • BASLER ELECTRIC MVC 108 MANUAL VOLTAGE CONTROL MODULE 9 0370 00 102
  • Basler BE1-59N-A7E-D1J-D0N0F Ground Overvoltage Relay
  • Basler BE1-46N-G1E-B8P-B0N0F Negative Sequence Overcurrent Relay
  • Basler BE1-951 Overcurrent Protection System
  • Basler Electric MOC2199 Motor Operated Potentiometer
  • Basler Electric BE1-60 Voltage Balance Solid State Relay B1FA1C1M1F
  • Basler Electric BE1-67N Directional Overcurrent Relay
  • Basler Electric PIA2400-17GM Interface Module
  • Basler Electric V6RAB Rectifier Module
  • Basler Electric BE1-32R Reverse Power Relay B2E E1R A0N1F
  • Basler Electric IFM-150 Firing Circuit Chassis 120V AC
  • Basler Electric IFM-102 Firing Circuit Chassis 120V AC
  • Basler Electric 9170206111 NSNP Control Module
  • Basler Electric SSR 63-12 Static Voltage Regulator
  • Basler UFOV 260A Overvoltage Protective Module
  • Basler SCA1300-32GM CCD Camera Lens Enclosure
  • Basler BA1-27 Under Voltage Relay
  • Basler 149D866G06 Control Board
  • Basler 9072300130 Power Supply Module
  • Basler CBS 305 Current Boost System
  • Basler BE1-60 Voltage Balance Relay
  • Basler Electric CBS 212 Current Boost System Sensing 120/240VAC 50/60Hz 10VA
  • Basler MVC-300 Manual Voltage Control Unit
  • Basler SSR125-12 Static Voltage Regulator 918500102
  • Basler SR32A2B05B3E Static Voltage Regulator
  • Basler Electric BE1-59N Ground Fault Overvoltage Relay
  • Basler Electric 9110000113 Excitation Module
  • Basler Electric 90-72300-114 Control Accessory
  • Basler Electric PRS-250 Protection Relay System
  • Basler Electric BE1-50/51M-109 Overcurrent Relay
  • Basler Electric SR4A1B10B3E Static Voltage Regulator
  • Basler Electric CBS 212 Current Boost System
  • Basler Electric SR32A2B05B3E Static Voltage Regulator
  • Basler Electric MOC2207 Motor Operated Potentiometer
  • Basler Electric SR4A1B05A3E Static Voltage Regulator
  • Basler Electric BE1-32R Power Relay B2EE1PA0N1F
  • Basler BEI-81 Underfrequency Relay
  • Basler CBS 212A Current Boost System
  • Basler SSR 63-12 Static Voltage Regulator
  • Basler DGC-2020 Digital Genset Controller
  • Basler BE1-32 Reverse Power Relay
  • Basler BE1-50/51B-207 Overcurrent Relay
  • Basler BE1-951 Overcurrent Protection System
  • Basler 9073800-103 Power Supply
  • Basler SCA1300-32FC CCD Camera
  • Basler 9073800-103 Power Supply
  • Basler SCA1300-32FC CCD Camera
  • Basler L304KC Protective Relay
  • Basler BE3-25-1S1N4 Time Overcurrent Relay
  • Basler 9032300113 Excitation Support System
  • Basler BE1-59N Ground Overvoltage Relay
  • Basler MVC-300 Manual Voltage Control Unit
  • Basler MOC2102 Potentiometer
  • Basler BE1-87G Generator Differential Relay
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric DECS 125-15-B2C5 Digital Excitation System
  • Basler Electric PLA2400-12GM Power Supply
  • Basler Electric BE1-50/51B-235 Overcurrent Relay
  • Basler Electric BE1-27/59 Undervoltage Overvoltage Relay
  • Basler Electric CEM-2020 Contact Expansion Module
  • Basler Electric BE1-32R Solid State Power Relay
  • Basler Electric BE1-700 Digital Generator Management Relay