Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

There are 6 methods of slope stability control in mine and quarry and 4 measures of ecological restoration

F: | Au:佚名 | DA:2024-01-11 | 861 Br: | 🔊 点击朗读正文 ❚❚ ▶ | Share:

As the demand for ore resources continues to increase, the ecological environment of the mine has been destroyed in a long term, resulting in a series of natural disasters such as soil erosion, landslides, debris flows and so on. Therefore, the restoration of the ecological environment of the quarry has increasingly become one of the problems that the society pays attention to.

1. Main contents of mine ecological restoration

1) Slope stabilization and reinforcement

After a long period of over-exploitation, the mine usually has the problem of geological instability and the mountain collapse and other safety hazards. Before the ecological restoration of the mountain, it is necessary to have a comprehensive understanding of the geological environment of the damaged mountain, analyze and demonstrate the risk of various geological disasters, and conduct current status assessment.

Through field survey and mapping, the distribution and scale of the damaged mountain, the susceptibility degree of mining side wall geological disasters, main inducing factors, stability, development and change trend, harm characteristics and so on are found.

According to the geological environment evaluation results, engineering treatment measures are adopted to treat the damaged mountain, such as removing the loose dangerous rock mass and potentially unstable blocks on the slope, cutting the steep slope, and system anchoring to strengthen the slope.

2) Mine vegetation restoration

In the process of mine ecological environment restoration, one of the most effective methods is to restore mine vegetation. The key point of this method is to first clarify the goal of mine ecological restoration, and conduct a comprehensive survey of the soil and environmental conditions of the mine, and then determine the method of vegetation planting.

3) Mine soil bioremediation

On the one hand, repairing soil microbes. The main method is to increase the activity of soil, and then increase the content of organic matter in soil. On the other hand repair soil animals.

A good repair of soil animals can effectively improve soil structure. Soil animals have the ability to decompose dead branches and residual branches, which can not only improve soil fertility, but also help soil plants complete the nutrient cycle.

2. Methods for the stability treatment of mine slope

Because the mining and stripping operation breaks the balance state of the original stress in the slope rock mass, the secondary stress field appears, which often causes the deformation and destruction of the slope rock mass and makes the rock mass unstable, resulting in caving, scattering, siting, toppling collapse and sliding. Before treatment, the safety assessment of the slope should be carried out first, and then the treatment begins.

General quarry slope treatment methods are as follows:

1) Slope cutting should be carried out for slopes with steep slope and unstable rock mass and deposits. For the steep slope with low height, it can also fill the pressure foot;

2) For the slope in the water-rich area, a combination of surface drainage and underground drainage plan must be formulated to carry out drainage, and if necessary, pilot holes can be drilled for drainage;

3) For the broken zone partially affected by geological structure, measures such as removal of dangerous rock or anchor rod and shotcrete support of steel mesh should be taken;

4) For slope rock weathering serious, easy to cause a small range of landslides after cutting the method of retaining wall treatment;

5) In order to prevent the pumice stone from falling and causing safety hazards, the slope must be cleaned and strictly inspected, and unsafe factors are found and dealt with in time. Then it can be combined with the greening project to lay metal mesh stone on the slope.

3. Measures for ecological restoration of mine slope

1) Clean the slope carefully

Slope treatment is one of the important contents in mine ecological restoration project. In order to do a good job in slope ecological restoration, the structure and geological condition of mine slope should be clearly defined first, and then the scientific treatment measures for mine slope should be determined. If the mine slope is a relatively loose mixture of soil and rock, it is necessary to clean the dangerous rock on the slope before treatment, and then take slope cutting measures combined with the design requirements to improve the smoothness of the slope.

2) Construct a scientific vegetation community structure

In order to improve the vegetation coverage rate of mine slope, suitable vegetation communities can be selected for planting. Since the species of shrub and grass plants are more suitable for growing in slope environment and have the advantages of self-sowing ability, such plants can be selected for planting in mine ecological restoration.

In order to improve the quality of ecological restoration, it is necessary to consider the specific form of mine slope, soil type, weathering condition, development degree of rock fissure and other factors.

3) Set up water interception and drainage facilities

If the mine slope does not do the layout of drainage facilities, surface water or groundwater will flow into the interior along the cracks in the rock mass, which will lead to the internal structure of the mine rock mass being softened and eroded over time, and eventually geological disasters such as landslides and soil erosion.

  • Sigmatek MDD111-1 DIAS Drive Axis Module
  • Sigmatek DKL042 05-024-042 Terminal Module
  • Sigmatek DM822 Control Module
  • Sigmatek CDM167 12-008-167-O Module
  • Sigmatek TAE151 Touch Display Unit
  • Sigmatek DCC041 SLIDES Module 05-700-041-D
  • Sigmatek AKM65M-ANC2GBB0 PM Servo Motor
  • Sigmatek ETT221 01-230-221 Operator Terminal
  • Sigmatek SLIDES DAM 124 Analog Module
  • Sigmatek AKM31C-ANCNGBB0 Servo Motor
  • Mannesmann Demag Sigmatek CP626 Central Unit
  • SIGMATEK 0332.554.03 Board 371071000154
  • SIGMATEK 12-250-021 Base Plate Back Panel CM5V020
  • SIGMATEK DM162 S-DIAS Digital Mix Module
  • DEMAG ERGOTECH 061 381 66 Sigmatek 9842.243.02 Circuit Board
  • SIGMATEK CP313-1 PLC Module
  • Sigmatek ETV0551-2 VARAN Touch Terminal
  • Sigmatek SDM 081 FS S-Dias Safety Module
  • DEMAG 05-250-023 Ergotech Motherboard with Sigmatek TMS012
  • Sigmatek CM5V020 12-250-023-K Wiring Base
  • Sigma Tek 5000B-37 Attitude Gyro Indicator
  • Sigmatek SDD120-2 DIAS Drive
  • Sigmatek CME221 Memory Module
  • Sigmatek DCP640 DIAS Central Unit
  • Sigmatek STO040 Safety Output Module
  • Sigmatek CET281 Control Panel
  • Sigmatek CIPC LX800 Demag NC5 CPU
  • Sigmatek DKL093 05-024-093 Terminal Module
  • Sigmatek AI088 20-009-088 Analog Input Module
  • Sigmatek CAI888 Analog Input Module
  • SIGMATEK CCA021 12-025-021 Analog Output Module
  • SIGMATEK 1104.579.05 Control Module
  • SIGMATEK SDI100 Digital Input Module
  • SIGMATEK C-IPC 256MB LX800 Compact Dias
  • SIGMATEK 9423.090.02 Control Module
  • SIGMATEK C-IPC 256 Power Supply 148498
  • SIGMATEK CAI025 Analog Input Module
  • SIGMATEK CTO166 Digital Output Module
  • SIGMATEK CP112 20-004-112 Processor Module
  • SIGMATEK CAI887 12-009-887 Safety Module
  • Sigma-Tek 4000B-31 Directional Gyro 1U262-002-42
  • Sigmatek C-IPC 256MB LX800 IPC Controller
  • Sigmatek C-IPC 01-450-031 Industrial PC LX800
  • Sigmatek C-IPC 256 Industrial PC Controller
  • Sigmatek CCP-531 PLC Processor Module
  • Sigmatek CDI163 Digital Input Module
  • Sigmatek ETV0501 VARAN Terminal 12-230-0501
  • Sigmatek CTMS020 C-DIAS Technology Module
  • Sigmatek CIV512 VARAN Switch Module
  • Sigmatek HU011 20-080-011 Interface Module
  • SIGMATEK SLIDES DAM 124 Module
  • SIGMATEK C-IPC 161 01-450-161L Industrial PC
  • SIGMATEK C-IPC 128MB VIA 733MHz 01-450-024-K
  • SIGMATEK 12-780-012 R8-IPC Geode LX800 Module
  • SIGMATEK CAM124 Analog Module
  • SIGMATEK S1 032-8AF61-R4 EZ Servo Motor
  • SIGMATEK CTO163 Digital Output Module
  • SIGMATEK CCP082 12-004-082 Processor Module
  • SIGMATEK CRCH081 C-DIAS Temperature Module
  • SIGMATEK PC322-K 01-310-322-K Industrial PC
  • SIGMATEK SDD310-2 Servo Drive
  • SIGMATEK AI084 Analog Input Module
  • SIGMATEK CRCH081 12-752-081 Temperature Module
  • Sigma-Tek 5000L-4 Attitude Gyro 1U284-001-3
  • SIGMATEK CM5V020 12-250-023-K Wiring Module
  • Sigma-Tek 4000H-6 Directional Gyro IU262-035-7
  • SIGMATEK Dias DCP160 05-004-160 Processor Module
  • SIGMATEK 0147.395.02 Control Module
  • SIGMATEK A1084 Control Module
  • SIGMATEK DI200 20-006-2000 Digital Input Module
  • Sigmatek DNC115 Encoder Module
  • Sigmatek DAM122 05-017-122 Analog Module
  • Sigmatek 9802.289.01 Control Board TA71 Display
  • Sigmatek TO127 20-007-127 Digital Output Module
  • Sigmatek DNC031 05-011-031 Digital Module
  • Sigmatek VI022 20-003-022 Interface Module
  • Sigmatek CAI085 Analog Input Module
  • Sigmatek CP111 S-DIAS CPU Module
  • Sigmatek CTMS030 Krauss Maffei Module
  • Sigmatek CAM123 Control Module
  • Sigmatek TAE732-P 01-240-732-P Touch Display Unit
  • Sigmatek MDM021 Digital Mixed Module
  • Sigmatek DCP642 DIAS Central Unit
  • Sigmatek CST022 12-014-022 C-DIAS Module
  • Sigmatek SRO021 20-893-021 Safety Relay Output
  • Krauss Maffei MC5 Control System Sigmatek
  • Sigmatek DC061 Module 18-24VDC 300mA
  • Herrmann EVT0855 Ultrasonic Welder Touch Panel
  • Sigmatek CIV521 Control Module 1.4A 2W
  • Sigmatek DDI61 05-006-161 Digital Input Module
  • SIGMATEK ETT312-E Touch Terminal 01-230-312
  • Cessna S3326-1 Sigma Tek 5000B-67 Gyro 1U149-015-9
  • SIGMATEK PS101 Power Supply Module
  • SIGMATEK 0332.554.03 Control Module 371071000154
  • SIGMATEK ETT312-E Touch Terminal 01-230-312
  • SIGMATEK CDM163 Control Module
  • SIGMATEK VSV046 16-023-046 Module
  • SIGMATEK AM221 20-017-221 Analog Module
  • SIGMATEK CTS051 12-053-051 Control Module
  • SIGMATEK AM221 20-017-221 Analog Module
  • Sigmatek CSDI161 12-891-161 Safety Input Module
  • Sigma Tek 4000C-1 Directional Gyro Indicator
  • Sigmatek ETV0501 12-230-0501 VARAN Terminal
  • Sigmatek DDM165 SLIDES Module
  • Sigmatek N100 20-011-100 Control Module
  • Sigmatek AKM54K-ANC2R-B0 PM Servo Motor
  • Sigmatek CTO166 Digital Output Module
  • Sigmatek CP212-K 20-004-212-K CPU Module
  • Sigmatek CDI161 Digital Input Module
  • Sigmatek DCC080 05-700-080-2 Control Module
  • SIGMATEK SCP011 S-DIAS Safety CPU
  • SIGMATEK SCP011 S-DIAS Safety CPU
  • SIGMATEK SRO022 Relay Output Module
  • SIGMATEK MDD 121 Drive Axis Module
  • SIGMATEK DSI021 SLIDES Siemens Interface
  • SIGMATEK DIAS DCP161 Module 05-004-161
  • Sigmatek ETT312 Built-in Touch Terminal
  • SIGMATEK DCP 643 DIAS Controller System
  • SIGMATEK CIO021 Multi I/O Module
  • SIGMATEK CTMS020 Control Module
  • Sigmatek CME 221 Memory Module
  • Sigmatek 0420.615.01 Control Board
  • Sigmatek CP111 20-004-111 CPU Module
  • Sigmatek 9405.065.03 Control Board
  • Sigmatek ETEK 01-450-032-K C-IPC 256MB Industrial PC
  • Sigmatek CTO163 12-007-163 Safety Output Module
  • Sigmatek TO081 20-007-081 Digital Output Module
  • Sigmatek SI021 20-022-021 Safety Input Module