The SM 1231 Thermocouple (TC) analog signal module measures the voltage value connected to the module input. The value can be the temperature measured by TC, or it can be the voltage.
● If it is voltage, the full scale value of the rated range will be the decimal number 27648.
If it is temperature, multiply the number of degrees by 10 to get the value (for example, 25.3 degrees will be reported as the decimal number 253).
Thermocouple Basics A thermocouple is formed when two different metals are electrically connected to each other. The voltage produced by the thermocouple is proportional to the temperature of the junction. The voltage is small; A microvolt can represent a lot of degrees. Measuring the voltage produced by a thermocouple, compensating for additional nodes, and then linearizing the measurement results are the basis for measuring temperature with a thermocouple. When connecting the thermocouple to the SM 1231 thermocouple signal module, two different metal wires need to be connected to the signal connector of the module. The position where these two different metal wires are connected to each other forms the sensor thermocouple. At the position where these two different metal wires are connected to the signal connector, two more thermocouples are formed. The connector temperature will cause a voltage that will be added to the voltage generated by the sensor thermocouple. If this voltage is not corrected, the resulting reported temperature will deviate from the sensor temperature. Cold end compensation is used to compensate the connector thermocouple. Thermocouple meters are based on the reference end temperature (usually zero degrees Celsius). Cold end compensation is used to correct the connector temperature to zero degrees Celsius. Cold end compensation eliminates the increased voltage of the connector thermocouple. The temperature of the module is measured internally, then converted to a numerical value and added to the sensor conversion. The corrected sensor conversion values are then linearized using a thermocouple meter. For optimal cold end compensation, the thermocouple module must be installed in a temperature-stable environment. Slow changes in module ambient temperature (below 0.1° C/min) that comply with module specifications can be correctly compensated. The flow of air through the module can also cause cold end compensation errors. For better cold end error compensation, an external iso hot terminal block can be used. Thermocouple modules can use 0° C reference value or 50° C reference value terminal blocks.
Choose Xiamen control Smith after sale worry
Excellent product quality
Only cooperate with manufacturers of first-line brands in the industry
Imports/Products
Good pre-sale service
Communicated with customers repeatedly about product model, quality, price and delivery date
Work with the customer to determine the best solution
Address user concerns in advance
Business execution in place
Ordered products delivered on time
Make perfect delivery plan to ensure the time limit
Assist users to handle the acceptance procedures
Perfect after-sales service
During the warranty period, problems will only be replaced and not repaired
Never put a problem on the back of your head
Service hotline 7x24 hours service
Solemn promise
1. All the items sold by the company, module card parts, etc., the quality problems arising from normal use during the warranty period are replaced free of charge, and there is no evasion.
2. For materials and equipment that have not been discontinued beyond the warranty period, only the cost of relevant parts will be charged for quality problems.
3. Provide replacement models and equipment replacement process services for discontinued materials and equipment.
4. Customers have purchased materials and equipment, lifetime free upgrade system software, related technical information provided free of charge.
5. Visit the use of materials purchased by customers from time to time, and solve any problems in time.
6. The company hotline provides 24-hour service, and the questions raised by customers are answered within 1 hour.
7. Not done, the company spirit of "thoughtful service, responsible to the end" attitude, from the customer's point of view to solve the problem, with serious and rigorous enterprise style, dedicated to each customer service.