ABB SPAD 346 C Stabilized Differential Relay Features:
Integrated three-phase differential relay, overcurrent relay and earth-fault relay
Stabilized three-phase differential relay providing winding short-circuit and interturn fault protection for two-winding transformers and generator-transformer units and winding shortcircuit protection for generators.
Earth-fault protection for transformer HV and LV side windings according to the desired principle: the stabilized differential current principle, the high-impedance principle, the calculated or measured residual current principle or the neutral current principle
Three-stage overcurrent protection for transformers and generators and two-stage back-up protection for earth-fault protection
The operation characteristic of the differential relay easily adapted for different applications
Short operate times, even with partially saturated current transformers
Stabilization prevents unwanted operations at faults outside the protected area and transformer inrush currents Blocking based on the ratio of the second harmonic and the fundamental component of the differential current prevents unwanted operations at transformer inrush currents
Blocking based on the ratio of the fifth harmonic and the basic frequency component of the differential current prevents operation in harmless situations of transformer overexcitation
- can be eliminated if the ratio of the fifth harmonic and the basic frequency component increases at high overvoltages
No interposing transformers are needed for the protection of two-winding transformers - numerical vector group matching on HV and LV side
Wide CT ratio correction range - accurate correction allowed by digital setting
Sensitive phase current and phase angle displays facilitate the checking of measurement circuit connection and vector group matching
Four trip and four signal relay outputs available to the protection design engineer
Five programmable external control inputs intended for the indication and retransmission of alarm and trip signals of gas relays, oil temperature sensors and other sensors of transformer auxiliary devices
Adjustable CBFP operate time to improve reliability of operation
Integrated disturbance recorder capable of recording currents and digital signals - signals to be used for triggering selectable
High immunity to electrical and electromagnetic interference allows the relay to be used in severe environments
High availability and system reliability due to continuous supervision of hardware and software