  • Siemens 6ES7350-2AH01-0AE0 Counter Module
    ❤ Add to collection
  • Siemens 6ES7350-2AH01-0AE0 Counter Module

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    Core positioning: 8-channel counter module, supporting 24V encoder, capable of counting, frequency measurement, speed measurement, cycle duration measurement, and proportional allocation functions. Comes with configuration package and electronic document (CD format), document date is April 16, 2012, content may be subject to further modification.

    • ¥7777.00
      ¥7454.00
      ¥7777.00
      ¥7777.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:20.640KG
    • Quantity:
    • (Inventory: 99999)
Description

Core positioning: 8-channel counter module, supporting 24V encoder, capable of counting, frequency measurement, speed measurement, cycle duration measurement, and proportional allocation functions. Comes with configuration package and electronic document (CD format), document date is April 16, 2012, content may be subject to further modification.


Siemens 6ES7350-2AH01-0AE0 Counter Module

Product basic information

Product model: 6ES7350-2AH01-0AE0

Belonging to the Siemens SIMATIC S7-300 series, specifically the counter module (FM 350-2)

Core positioning: 8-channel counter module, supporting 24V encoder, capable of counting, frequency measurement, speed measurement, cycle duration measurement, and proportional allocation functions. Comes with configuration package and electronic document (CD format), document date is April 16, 2012, content may be subject to further modification.

Core electrical specifications

(1) Power supply and power consumption

Parameter category details

Supply voltage - auxiliary voltage 1L+, load voltage 2L+: direct current (DC) 24V, allowable range 20.4V-28.8V

-Encoder power supply: NAMUR encoder output voltage 8.2V ± 2%, rated output current 200mA, with short-circuit protection

Input current load voltage L+(no load): maximum 150mA

-Backplane bus 5V DC: maximum 100mA

Typical power loss value 10W

(2) Digital input characteristics

Specific specifications of input parameters

Number of channels: 8 binary input channels, each corresponding to 1 door start/stop function

Signal Level - Signal "0": -3 to+5V

-Signal "1": 11 to 30.2V

Input current - signal "0": maximum 2mA (static current allowed)

-Signal "1": Typical value 9mA

When switching from input delay standard "0" to "1", the maximum delay is 50 μ s

Cable length: Shielded cable, maximum 100m

(3) Digital output characteristics

Specific specifications of output parameters

Number of channels: 8 binary output channels with short-circuit protection capability

Inductive turn off voltage limit up to L+(-40V)

Minimum L+(-0.8V) when outputting voltage signal "1"

Output current - signal "1" rated value: 0.5A

-Residual current of signal '0': maximum 0.5mA

Output delay: Under resistive load, the maximum switching delay from "0" to "switching" is 300 μ s

Switching frequency - resistive load: maximum 500Hz

-Inductive load: maximum 0.5Hz

Output total current (per group) - Horizontal installation: maximum 4A below 40 ° C, maximum 2A below 60 ° C

-Other installation locations: maximum 2A below 40 ° C

Cable length - shielded cable: maximum 600m

-Unshielded cable: maximum 100m

image.png

Encoder and Counting Function Specifications

(1) Compatible with encoder types

Supports incremental encoders (asymmetric), 24V triggers, 24V directional components, NAMUR encoders, and 2-wire sensors.

(2) NAMUR encoder specific parameters

Parameter specifications

NAMUR input quantity 8

The input signal standard complies with DIN 19234

Input current - signal "0": maximum 1.2mA

-Signal "1": minimum 2.1mA

Maximum input delay of 50 μ s

Maximum input frequency 20kHz

Cable length: Shielded cable, maximum 100m

(3) Counter core parameters

Counting parameter specifications

8 counters, supporting 32-bit or ± 31 bit counting

Input voltage - signal "0": -3 to+5V

-Signal "1": 11 to 30.2V

Input current - signal "0": maximum 2mA (static current allowed)

-Signal "1": Typical value 9mA

Maximum input delay of 50 μ s

The maximum counting frequency is 20kHz (incremental encoder is 10kHz)

The maximum cable length is 100m


Mechanical and isolation specifications

(1) Size and weight

Dimensions: Width 80mm, Height 125mm, Depth 120mm

Weight: Approximately 460g

Connection method: 1 40 pin front connector is required

(2) Electrical isolation

Isolation status of isolated objects

Isolation between digital input channel and backplane bus (including shielding)

NAMUR input channel and backplane bus and shield: isolated

Isolation between digital output channel and backplane bus (including shielding):

Isolation between counter channel and backplane bus (including shielding):


Functional characteristics

Interruption and Diagnosis

Functional Category Capability Details

Alarm function supports parameterized diagnostic alarms and parameterized hardware interrupts

The diagnostic function has diagnostic capabilities and can read diagnostic information

Status indicator red group error indicator light (SF): displays group error status


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Toshiba T1-16S Programmable Controller I/O Module Detailed Explanation
  • CE 680 M511 industrial piezoelectric accelerometer
  • Hardware Explanation of Meggitt VM600 MPS Mechanical Protection System
  • Meggitt Vibro meter VM600Mk2 Mechanical Protection and Condition Monitoring System
  • WAGO MCS Connection System
  • WAGO 281-611 Fuse Terminal Analysis
  • Watlow PPC-2000 System Deployment and Configuration Guide
  • Watlow MLS Controller Guide
  • Watlow 8LS Controller Setup Guide
  • Watlow Anafaze System 32 Hardware Installation Guide
  • Watlow ANAFAZE 12LS Installation and Operation Technical Guide
  • Baldor NextMove ST Motion Controller Technical Guide
  • Baldor MotiFlex e100 Servo Drive Installation Guide
  • Baldor FlexDrive II AC Guide
  • Baldor MicroFlex Servo Drive Professional Installation Guide
  • ABB MicroFlex servo drive characteristics and installation guide
  • Baldor BSM Series AC Servo Motor Analysis
  • Baldor Reliability CDPT3320 DC Motor
  • Baldor Reliability NEMA Super-E Ultra High Efficiency Motor Comprehensive Guide
  • Baldor Reliance Full Horsepower DC Motor Comprehensive Guide: From Technical Specifications to Industrial Application Selection
  • Comprehensive Guide to Baldor Motion Control Accessories: HMI Panels, Industrial Cables, Power Supplies, and EMC Filters
  • HIMA HICore 1 In Depth Analysis: A Comprehensive Guide to Functional Safety SoCs, Evaluation Kits, and T Ü V Certification
  • HIMA HIJunctionBox: Creating a New Era of Distributed Intelligent Security Platform
  • HIMA HIMatrix F35 Safety Controller: Specification Manual, SIL 3 Programming and Installation Guide
  • HIMA HIQuad X System Manual: Comprehensive and in-depth analysis of HIMA SIL 3 safety automation system
  • Deep Analysis of HIMA HIMax Safety Control System: Architecture, Redundancy, and Engineering Application Guidelines
  • In depth analysis of HIMA Planar4 system: SIL 4 level hard wired safety logic solution
  • What are the core protection mechanisms of WOODWARD Vertex's anti surge control?
  • Woodward Vertex Compressor Control System: Function, Application, and Installation Details
  • Woodward easYview miniSCADA visualization solution
  • Woodward easyYview Series: Technical Analysis of Mini SCADA Remote Control Panel Designed for Generator Sets and Switchgear
  • Woodward MicroNet Plus: High reliability redundant control system for prime mover control
  • Woodward easyYgen LS-6XT: A Multi Circuit Breaker Control Solution for Complex Power Management
  • Woodward easyYgen LS-6XT Circuit Breaker Control Unit: Technical Characteristics, Installation and Application Guide
  • Woodward LS-521 V2 (Option K12) Circuit Breaker Control Unit
  • Woodward MicroNet TMR 5009 Digital Control System: Authoritative Guide to Hardware Installation and Configuration
  • Woodward MicroNet ™ Analysis and Application of Simplex and Plus Digital Control Systems
  • WOODWARD MSLC-2XT™ Master Synchronizer and Load Control
  • Woodward DSLC Digital Synchronizer and Load Controller: Installation, Operation, and Troubleshooting Guide
  • WOODWARD DSLC-2 Digital Synchronizer and Load Control
  • From Beginner to Proficient: Woodward easyYgen-3000 Controller Interface Configuration, CANopen, J1939 and Modbus Communication Practical Guide
  • WOODWARD easYgen-3000 Series (Package P1) Genset Control
  • WOODWARD ® ProTech‐SX Safety System with Integrated Overspeed Protection
  • Woodward ProTech SX Simplex System: Turbine Single Channel Safety Protection System
  • Woodward QuickTrip Electro Hydraulic Trip Module Components: High Reliability Turbine Safe Shutdown Solution
  • WOODWARD QuickTrip Electro-Hydraulic Trip Block Assembly
  • WOODWARD VariStroke Hydraulic Power Cylinder (VHPC)
  • WOODWARD VariStroke GI single acting electro-hydraulic actuator: a reliable solution for turbine control
  • Woodward VariStroke DX hydraulic servo dual redundant sled
  • Woodward VariStroke-I electro-hydraulic actuator: an innovative solution for steam turbine valve control
  • WOODWARD MicroNet TMR ® OpView of 5009 Digital Control System ™ Interface Operation Manual
  • WOODWARD 5009XT Fault-Tolerant Control
  • Woodward PG-PL Hydraulic Governor: Reliable and Accurate Engine and Turbine Speed Control Solution
  • WOODWARD 2301A Speed Control Controller: A Classic and Reliable Engine and Turbine Speed Control Solution
  • XP POWER VFR05 Series 5W Convertible Plug AC-DC Adapter
  • XP POWER VFL05 Series 5W Wall Mounted AC-DC Power Adapter
  • XP POWER AQM200 Series 200W Natural Cooling Medical Grade AC-DC External Power Supply
  • XP POWER CB Series 1W Natural Cooling Micro High Voltage DC-HVDC Converter
  • XP POWER CDX Series 1500W Dual Frequency RF Power Supply
  • XP POWER RDF25 Series 5W Bottom Cooling DC-DC Converter
  • XP POWER ITX Series 6W DC-DC Converter: A Concise and Efficient Solution
  • XP Power Technical Guide: In Depth Analysis of AC/DC Conversion, System Topology, and High Reliability Design
  • XP POWER C Series Micro Stabilized High Voltage DC-DC Converter
  • XP POWER EHL05 Series 5W AC-DC Power Supply: A Wide Input Solution Designed for 480VAC Systems
  • XP Power: The world's leading expert in power conversion and its full range of solutions
  • XP POWER HDA1500 Series 1.5kW High Power AC-DC Power Supply
  • XP POWER SMP350 Series Fan Cooling 350W AC-DC Power Supply
  • XP POWER MP Series 300-2400 Watts AC-DC Power Supply
  • How to install the YAMAHA RCX40 four axis robot controller?
  • HIMA HIMax X-AO 16 01 Analog Output Module: SIL 3 Safety Certification and Key Technical Features
  • HIMA HIMax ® System Manual is applicable to safety related control systems
  • Hirschmann Industrial Ethernet Switch
  • YASKAWA A1000 series AC frequency converter
  • HIRSCHMANN MACH1040 family Full Gigabit Industrial Ethernet Ruggedized Switch
  • How to operate the Hirschmann MICE series media module and expansion module?
  • How to install Hirschmann MS20/MS30 series industrial Ethernet switches?
  • Hirschmann GUI Graphical User Interface Industrial ETHERNET (Gigabit-)Switch RS20/RS30/RS40, MS20/MS30
  • HIRSCHMANN MICE series modular industrial communication equipment
  • TOSHIBA TOSBERT VF-AS3 series
  • TOSHIBA MG08-D SERIES ENTERPRISE CAPACITY HDD
  • Triconex Tricon™ v9–v11 Systems Planning and Installation Guide
  • XYCOM XVME-100 memory module
  • ABB Ability™ Symphony® Plus MR Series
  • BENTLY 3500/15 AC and DC Power Supplies
  • HITACHI S10VE Programmable Controller
  • ABB SYNCHROTACT ® 5 synchronous devices
  • YASKAWA SGMCS series direct drive servo motor
  • YASKAWA GA700 series AC frequency converter
  • YASKAWA ∑ - V series AC servo drive
  • YASKAWA S-7 series linear servo
  • YASKAWA GA500 series AC micro frequency converter
  • YASKAWA 1000 series frequency converter
  • YASKAWA 120 Series I/O Modules
  • YASKAWA MEMOCON-SC 2000 series reversible counter module
  • YASKAWA Machine Controller MP2000 Series
  • Yaskawa VARISPEED-626M5 frequency converter
  • Yaskawa CP-9200SH Controller
  • WESTINGHOUSE eVinci ™ Micro reactor
  • WESTINGHOUSE HC series molded case circuit breaker
  • WESTINGHOUSE MAX-VH ™/ MAX-VHP ™ Series vertical hollow shaft induction motor
  • WESTINGHOUSE Alpha Plus Series Low Voltage Distribution System
  • WESTINGHOUSE Three Phase Induction Motors
  • WESTINGHOUSE iGen5000 Digital Inverter Generator
  • WESTINGHOUSE E510 series compact AC frequency converter (VFD)
  • WESTINGHOUSE E-Series MCCB (Molded Case Circuit Breaker)
  • WESTINGHOUSE Transformer Product Line
  • Emerson Ovation OCR1100 Controller
  • BENDER Isolated Power Panels
  • Bender LifeGuard® LG2-Series Protection Panels
  • Bender LINETRAXX ® CTAC series AC measurement current transformer
  • Bender GPM series grounding power module
  • BENDER LINETRAXX® CTUB100 series AC/DC sensitive measuring current transformers (type B)
  • Bender LifeGuard ® LG2 series protective panel
  • BENDER ISOMETER ® Iso685 series
  • BENDER Greenlee 555C Electric Pipe Bending Machine
  • BENDER ISOMETER® iso685(W)-D/-S Insulation Monitoring Device
  • BENDER LINETRAXX ® VMD420 Three phase Voltage Frequency Monitor
  • BENDING 77 Series Electric Bender with Single Shoe Groups
  • BENDER EDS3090 series portable grounding fault location system
  • BENDER ISOSCAN ® EDS460/490-EDS461/491 series
  • Bender EDS3090/-91/-92/-96 series
  • SMC IRV10/20 series vacuum regulator
  • BMCM AMS42/84 5B amplifier system
  • ABB AFS series switches
  • NI VXIpc-870B Series Embedded Pentium III VXIbus Controllers
  • BENDER ISOMETER ® IRDH265/365 series Insulation Monitoring Equipment
  • BENDER ISOMETER ® IRDH375 series Insulation Monitoring Equipment
  • BENDER WR70x175S (P)... WR200x500S (P) rectangular measuring current transformer