IS200EMCSG1AA High-Performance Mark VI Circuit Board for Industrial Control
Dimension:12 x 8 x 7 cm Weight:0.35 kg Operating Temperature:-20"C to +60"C Power Consumption:15 W Communication Protocol:Modbus RTU, Ethernet/IP Memory Capacity:16 KB RAM, 32 KB ROM The GE IS200EMCSG1AA is specifically engineered to withstand harsh industrial conditions, ensuring uninterrupted operation even in the most challenging environments. Equipped with advanced communication protocols, this circuit board seamlessly integrates with various control systems, enhancing operational flexibility and efficiency.
Featuring an optimized design for improved heat dissipation, the GE IS200EMCSG1AA ensures long-term reliability and minimal downtime. With its robust memory capacity, this circuit board can handle complex data processing tasks without compromising performance, making it ideal for sophisticated industrial automation setups. Manufactured from high-quality materials, the GE IS200EMCSG1AA is built to endure the rigors of industrial use, delivering consistent performance over extended periods. The GE IS200EMCSG1AA Mark VI Circuit Board is specifically designed for high-performance industrial control systems, offering unparalleled reliability and efficiency in various applications.
Compatibility
ƒ Compatible with any Series 90-30 CPU except IC693CPU321 and IC693CPU340. Configuration size is limited for CPU311/313/331, as described on the next page.
ƒ Requires release 8.0 CPU firmware. The latest Release 10 is recommended, if available for the particular CPU.
ƒ Requires CIMPLICITY Machine Edition Logic Developer PLC version 3.0 plus the appropriate service pack or special (or a version later than 3.0).
ƒ Not compatible with the VersaPro™, Control, or Logicmaster™ programming software.
ƒ The Series 90-30 Hand-Held Programmer (IC693PRG300) cannot be used to configure this module. New Features The Series 90-30 DeviceNet Master Module allows a Series 90-30 PLC to send and receive I/O data from a DeviceNet network.
Module features include:
ƒ Support for all standard data rates (125K, 250K, 500K)
ƒ Support for 255 bytes input data transfer and 255 bytes output data transfer per slave
ƒ Support for 3972 bytes of input data transfer and 3972 bytes of output data transfer per master
ƒ Support for two I/O connections per Slave - Typically one connection is used for Polled and the other is used for Strobe, Cyclic, or COS
ƒ Support for Poll, Strobe, Cyclic and COS I/O Connections, Fragmented I/O and Explicit Messaging
ƒ Support for Unconnected Message Manager (UCMM) with 1 proxy connection per slave device
ƒ Support for configuration of the global scan rate
ƒ Support for configuration of update rates for Poll and COS/Cyclic on a connection basis
ƒ Support for PLC-application initiated explicit messaging via a COMMREQ
ƒ Master can be configured to operate as a slave simultaneously with master operation
ƒ Configurable fault behavior on loss of communication
ƒ Reports loss or reestablishment of communication with slaves in PLC fault table (configurable)
ƒ Support for 64 network device status bits (note: the bit for the master itself is always zero)
ƒ Firmware update via service port on module