Close the optical module latch and insert it into the device SFP slot until the latch locks in place.
Note: Only use compatible SFP optical modules specified by HIRSCHMANN. Please refer to the "Accessories" section for specific models.
2. Power supply and signal contact wiring
Terminal block disassembly: First, remove the power terminal block and signal contact terminal block from the equipment for easy wiring.
Power supply wiring: Connect according to the terminal definition (Pin1: protective conductor, Pin2: DC negative/AC neutral wire, Pin3: DC positive/AC phase wire), ensuring that the wiring is firm and the torque meets the requirements.
Signal contact wiring: Use 0.5-3.0mm ² (AWG20-AWG12) copper wire with a stripped length of 12mm; ensure that the cable is free of voltage, connect and tighten the terminal block with the required torque.
Terminal block installation: Reinstall the connected terminal block back into the device.
3. Equipment fixation and grounding
Cabinet installation: Install sliding/mounting rails in a 19 inch cabinet according to the manufacturer's requirements, and secure the equipment to the rails with screws through side pre installed brackets; Additional back support brackets (accessories) can be installed in strong vibration environments.
Wall installation: Adjust the pre installed bracket position of the equipment, install additional back brackets (accessories), and fix the bracket to the wall with screws to ensure that the equipment is vertical and stable.
Grounding operation: Connect the grounding screw on the back of the equipment to the protective conductor with a grounding wire. The cross-section of the grounding wire meets the requirements and the connection is firm.
4. Data cable connection
Twisted pair connection: Use Cat5e and above specification cables with a maximum length of 100m; shielded cables (such as SF/UTP, in compliance with ISO/IEC 11801) are required for strong interference environments; Maintain sufficient distance from power cables, avoid parallel laying, and try to form a 90 ° angle when crossing to reduce interference.
Fiber optic connection: Ensure that the SFP optical module model matches the fiber optic type (SX/LX/LH, etc.), and interconnect ports of the same type (such as SX-SX); Pay attention to cleaning the fiber end face during connection to avoid contamination.
5. Equipment power on and status check
After confirming that all wiring is correct, secure, and there is no risk of short circuit, connect the power supply.
Observe the LED indicator light: The device status light shows that the power supply is normal (P light green light is on), and there is no fault (FAULT light is not on); After the port is connected, the corresponding port LED lights up green, and the yellow light flashes during data transmission, confirming that the installation is normal.
(3) Verification after installation
Check if the device's heat dissipation is normal, without any abnormal heating or noise.
Confirm the port connection status through LED or management tools and test whether data transmission is smooth.
After installation in hazardous environments, it is necessary to confirm that the explosion-proof configuration meets the requirements and there are no safety hazards.
Initial configuration and management operations
(1) Initial login and password modification
Configuration method selection:
Local configuration: Connect to a PC or VT100 terminal through the V.24 interface, with terminal parameters set to 9600 baud rate, 8-bit data bits, 1-bit stop bit, no checksum, and no handshake.
Remote configuration: Connect the device through a web browser, Telnet, or HiView software (default IP address obtained through DHCP).
First login: Use the default account login - administrator account (admin/private, read-write permission), regular user account (user/public, read-only permission).
Password modification: After the first login, the device requires the administrator password to be changed. The new password must include uppercase and lowercase letters, numbers, special characters, and be at least 8 characters long; After modification, log in again for verification.
Password retrieval: If you forget your password, you need to reset it through System Monitor. Please refer to the official website's knowledge base for specific procedures.
(2) Core default parameters and configuration points
Suggestions for configuring default settings for parameter categories
IP address automatically obtained through DHCP in industrial scenarios. It is recommended to set a static IP address to avoid IP conflicts
Port mode automatic negotiation is enabled, supporting automatic polarity, automatic crossover, and terminal device matching without manual adjustment; In special scenarios, automatic negotiation can be turned off, and the speed and duplex mode can be manually set
The PoE function supports IEEE 802.3af, and the first 4 ports are PoE ports that can be enabled/disabled according to terminal requirements to avoid ineffective power supply
Disabling ring network redundancy requires enabling HIPER Ring functionality, configuring control ports and coupling ports for ring network topology