Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

HIRSCHMANN MACH1040 family Full Gigabit Industrial Ethernet Ruggedized Switch

来源: | 作者:FAN | 发布时间 :2025-12-31 | 392 次浏览: | 🔊 Click to read aloud ❚❚ | Share:

Close the optical module latch and insert it into the device SFP slot until the latch locks in place.

Note: Only use compatible SFP optical modules specified by HIRSCHMANN. Please refer to the "Accessories" section for specific models.

2. Power supply and signal contact wiring

Terminal block disassembly: First, remove the power terminal block and signal contact terminal block from the equipment for easy wiring.

Power supply wiring: Connect according to the terminal definition (Pin1: protective conductor, Pin2: DC negative/AC neutral wire, Pin3: DC positive/AC phase wire), ensuring that the wiring is firm and the torque meets the requirements.

Signal contact wiring: Use 0.5-3.0mm ² (AWG20-AWG12) copper wire with a stripped length of 12mm; ensure that the cable is free of voltage, connect and tighten the terminal block with the required torque.

Terminal block installation: Reinstall the connected terminal block back into the device.

3. Equipment fixation and grounding

Cabinet installation: Install sliding/mounting rails in a 19 inch cabinet according to the manufacturer's requirements, and secure the equipment to the rails with screws through side pre installed brackets; Additional back support brackets (accessories) can be installed in strong vibration environments.

Wall installation: Adjust the pre installed bracket position of the equipment, install additional back brackets (accessories), and fix the bracket to the wall with screws to ensure that the equipment is vertical and stable.

Grounding operation: Connect the grounding screw on the back of the equipment to the protective conductor with a grounding wire. The cross-section of the grounding wire meets the requirements and the connection is firm.

4. Data cable connection

Twisted pair connection: Use Cat5e and above specification cables with a maximum length of 100m; shielded cables (such as SF/UTP, in compliance with ISO/IEC 11801) are required for strong interference environments; Maintain sufficient distance from power cables, avoid parallel laying, and try to form a 90 ° angle when crossing to reduce interference.

Fiber optic connection: Ensure that the SFP optical module model matches the fiber optic type (SX/LX/LH, etc.), and interconnect ports of the same type (such as SX-SX); Pay attention to cleaning the fiber end face during connection to avoid contamination.

5. Equipment power on and status check

After confirming that all wiring is correct, secure, and there is no risk of short circuit, connect the power supply.

Observe the LED indicator light: The device status light shows that the power supply is normal (P light green light is on), and there is no fault (FAULT light is not on); After the port is connected, the corresponding port LED lights up green, and the yellow light flashes during data transmission, confirming that the installation is normal.

(3) Verification after installation

Check if the device's heat dissipation is normal, without any abnormal heating or noise.

Confirm the port connection status through LED or management tools and test whether data transmission is smooth.

After installation in hazardous environments, it is necessary to confirm that the explosion-proof configuration meets the requirements and there are no safety hazards.


Initial configuration and management operations

(1) Initial login and password modification

Configuration method selection:

Local configuration: Connect to a PC or VT100 terminal through the V.24 interface, with terminal parameters set to 9600 baud rate, 8-bit data bits, 1-bit stop bit, no checksum, and no handshake.

Remote configuration: Connect the device through a web browser, Telnet, or HiView software (default IP address obtained through DHCP).

First login: Use the default account login - administrator account (admin/private, read-write permission), regular user account (user/public, read-only permission).

Password modification: After the first login, the device requires the administrator password to be changed. The new password must include uppercase and lowercase letters, numbers, special characters, and be at least 8 characters long; After modification, log in again for verification.

Password retrieval: If you forget your password, you need to reset it through System Monitor. Please refer to the official website's knowledge base for specific procedures.

(2) Core default parameters and configuration points

Suggestions for configuring default settings for parameter categories

IP address automatically obtained through DHCP in industrial scenarios. It is recommended to set a static IP address to avoid IP conflicts

Port mode automatic negotiation is enabled, supporting automatic polarity, automatic crossover, and terminal device matching without manual adjustment; In special scenarios, automatic negotiation can be turned off, and the speed and duplex mode can be manually set

The PoE function supports IEEE 802.3af, and the first 4 ports are PoE ports that can be enabled/disabled according to terminal requirements to avoid ineffective power supply

Disabling ring network redundancy requires enabling HIPER Ring functionality, configuring control ports and coupling ports for ring network topology

  • Telemecanique LAD-N22C Auxiliary Contact Block
  • TEAM BL0170 PC0010-P Industrial Controller
  • TEAM BG0090 PC0006 Industrial Control Board
  • Techno KR-505M Stepper Motor Controller
  • Teikoor CPCIAC-6U-500 CompactPCI AC Power Supply
  • TEL MBMY-001A VME Memory Board
  • TEL VME-U10 B VME Single Board Computer
  • TEL TVB-1202-1 ANET VME Bus Termination Board
  • ALSTOM GDS1168-6216 Signal Converter Module
  • Tokyo FAO111A Industrial Control Module
  • Toshiba AFX-90L-RH XRF Analyzer Tube
  • Toshiba GBU648E S Bridge Rectifier Module
  • Toshiba TCPSV Servo CPU Module J7000 Series
  • Toshiba HFAS11S Servo Drive Module
  • TOYOA MC256-C Servo Controller Module
  • TEL TVB6002-1 1308-644857-12 RF Control Interface
  • TEL TVB3101-1 1381-644957-16 RF Module Specs
  • Telemecanique BW06 Industrial Limit Switch
  • Teradyne A1004-00003 398-723-00 Interface Board
  • Leybold THERMOVAC TR301 15740 Vacuum Transmitter
  • TOKYO TK6132A8 Industrial Control Module
  • TOYOPUC OUT-16 THK-2791 PLC Output Module
  • TPC FFLC6-3483-B Industrial Interface
  • TPC FPX86-9345-B Pneumatic Control
  • TR Electronic ZE65M Absolute Encoder
  • TRACO POWER T1032-07C Industrial DC/DC Converter
  • TRACO POWER T1023-07C High-Efficiency Power Module
  • Trafo SLOV4.6/5.3 3BHL000734P0003 Isolation Transformer
  • Trafotek CHK0520 Current Transformer
  • Transcend 128MB PC133 SDRAM Memory Module
  • Transition Networks J/E-CF-02 Media Converter
  • TRASFOR DRMBW20/L 3BHB009181P0001 Drive Power Module
  • TRASFOR DRMBW30/L 3BHB009182P0001 Rectifier Transformer Module
  • Trenew VME-GrundSystem VMEbus Chassis
  • Trumpf TE 1605341 VER02 Circuit Board
  • Trumpf MBE3-50 Laser Control Electronics
  • TSC Carat 1008FC Industrial Power Module
  • Turck FDNL-L0800-T DeviceNet Fieldbus I/O Module
  • Turck MK35-LI-EX0 Intrinsically Safe Isolation Amplifier
  • Turck MK33-LI-EX0 Intrinsically Safe Inductive Sensor
  • Turck JBBS-49-E413/3 PROFIBUS DP Junction Box
  • Turck BL20-16DI-24VDC-P Digital Input Module
  • TWUNCOM J592S-450550 Dual Serial I/O Module
  • TE Connectivity KUEP-11D15-24 General Purpose Relay
  • UE LDP1WC 250P-16 Low Differential Pressure Switch
  • UniOP ETT-VGA-0045 Operator Panel
  • UniOP TCM08A Communication Module
  • UniOP ETT-VGA HMI Terminal Technical Specifications
  • Vacon PC00459G CM210901 Control Board
  • Valmet CXW D201435L Controller
  • Valmet A413305 I/O Module
  • Valmet A413280 DNA System Processor Module
  • Valmet CPR1 A413280 Processor Module
  • Valmet A413295 Valve Controller Module
  • Valmet A413285 Industrial Control Module
  • Valmet A413052 8-Channel Analog Output Module
  • Valmet A413045 Industrial Control CPU Module
  • VIBRO-METER 200-595-002-011 Interface Module
  • VIBRO-METER 573-935-202C Monitoring Module
  • VIBRO-METER VM600 MPC4 200-510-111-034 Monitoring Card
  • VIBRO-METER MPC4 200-510-076-115 Protection Monitoring Card
  • VIBRO-METER CMC16 200-530-022-014 Communication Module
  • VIBRO-METER MPC4 200-510-111-035 Machinery Protection Card
  • VAT 65040-PACV-AYU2/9049 Vacuum Valve Controller
  • Vibrack VK5488E-107S Vibration Transmitter
  • Vibro-Meter VM600 IOC16T 200-565-000-013 I/O Specs
  • Vibro-Meter 200-566-000-012 IOCN Network Interface
  • Vibro-Meter VM600 200-560-000-113 IOC4T Input Output Card
  • Vibro-Meter VM600 200-582-915-032 Power Supply
  • Vibro 573-935-202C VM600 Control Module
  • Vibro 200-595-002-011 VM600 CPUM Processor Module
  • Vibro-meter VM600 MPC4 200-510-111-034 200-510-070-113 Protection Card
  • Vibro-meter MPC4 200-510-076-115 Machinery Protection Card
  • Vibro-meter CMC16 200-530-022-014 Machinery Protection Rack
  • Vibro-meter MPC4 200-510-111-035 Vibration Monitoring Module
  • Vibro-meter CMC16 16-Slot Machinery Protection Rack
  • Vibro-meter MPC4 4-Channel Protection Card
  • Vibro-meter VM600 IOC4T 4-Channel I/O Module
  • Vibro-meter VM600 204-040-100-012 System Controller
  • Vibro-meter VM600 PNR200-570-000-111 Relay Module
  • Vibro-Meter VM600 IOCN 200-566-000-112 Network Interface
  • Vibro-Meter VM600 IOC16T 200-565-000-013 I/O Card
  • Vibro-Meter VM600 RPS6U 200-582-500-013 Power Supply
  • Vibro-Meter VM600 CMC16 200-530-022-014 Monitoring Card
  • Vibro-Meter VM600 MPC4 200-510-070-113 Protection Card
  • Vibro-meter VM600 204-040-100-012 System Controller
  • Vibro-meter VMF IOCN Network I/O Module
  • Vibro-meter VMF RLC16 Relay Output Module
  • Vibro-meter VMF IOC4T 4-Channel I/O Module
  • Vibro-meter VMF IOC16T 16-Channel I/O Module
  • Vibro-Meter CMC16 200-530-111-013 Condition Monitoring Card
  • Vibro-Meter CPUM 200-595-046-114 Advanced Rack Controller
  • Vibro-Meter MPC4 200-510-111-034 Machinery Protection Card
  • Vibro-Meter CPUM 200-595-045-114 Rack Controller
  • Vibro-Meter SIM-275A 200-582-500-013 Signal Interface
  • Vibro-Meter VM600-CSA 204-040-100-211 Redundancy Module
  • Vibro-meter VM600 204-040-100-012 System Controller
  • Vibro-meter VM600 RLC16 Relay Module
  • Vibro-meter VM600 RPS6U Redundant Power Supply
  • Vibro-meter VM600 CMC16 Machinery Protection Rack
  • Vibro-meter VM600 ABE042 System Controller Card
  • Vibro-Meter VM600 RPS6U 200-582-200-011 Power Supply
  • Vibro-Meter VM600 RLC16 Relay Card
  • Vibro-Meter VM600 IOC4T 200-560-000-018 Input Output Card
  • Vibro-Meter VM600 XIO16T 620-003-111-112 Input Output Module
  • Vibro-meter VM600 XMV16 Vibration Measurement Card
  • Vibro-meter VM600 ABE040 System Controller Card
  • Vibro-Meter 444-680-000-511 Signal Conditioning Module
  • Vibro-meter VM600 CMC16 Machinery Protection System
  • VIPA 62K-NHC0-DH Touch Panel HMI
  • VIPA 972-0DP10 PROFIBUS DP Interface Module
  • VMIC Assy 11993R2 Circuit Board Assembly
  • VMIC 11-1001245-01 Industrial Module
  • VMIC ZT5524A1A CompactPCI Intelligent Controller
  • VMIC VMIVME-2533 32-Channel Digital I/O Module
  • Vortran LST200 Laser Diode Control System
  • Vortran Stradus 405nm Laser Module
  • Vishay 120NQ045R Schottky Rectifier Diode
  • VMIC VMIVME-7740-840 Pentium III VME SBC
  • VMIC VMIVME-7740-855 PowerPC VME Single Board Computer
  • VMIC VMIVME-1128 128-Bit High Voltage Digital Input Board
  • VMIC ASSY 12149 VMEbus Single Board Computer
  • VMIC ASSY 11994R13 VMEbus Industrial I/O Module
  • Wavecrest DTS-2079 High-Performance Controller Module
  • Wurth Elektronik 74271132 WE-STAR-TEC Snap Ferrite
  • Woodward 9907-165 Digital Turbine Control Module
  • DS1230Y-150+ 256Kb Non-Volatile SRAM Maxim Integrated
  • ZIPPE MWS10/A Industrial Weighing Transmitter Module